Dragana Arlov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dragana Arlov has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ases Akas Mishra
Chalmers University of Technology, Department of Industrial and Materials Science Göteborg Sweden
2 shared publications - David Ian Wilson
University of Cambridge
2 shared publications - Robert Stewart Cant
Department of Engineering, University of Cambridge, Cambridge, UK
2 shared publications A.T. Bagdziunas
1 shared publication- Amit Kumar Siva Kumar
Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 412 96 Gothenburg, Sweden
1 shared publication - Andreas Håkansson
Department of Process and Life Science Engineering, Lund University, Lund, Sweden
1 shared publication
Latest Publications
- Open Access
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Heat Exchanger Network Optimization and Cleaning Scheduling under Fouling: Application to UHT Dairy Heat Recovery
Heat exchanger networks (HENs) are widely used to reduce utility consumption in industrial thermal processes, but their performance is often limited by fouling and cleaning-related production interruptions. In hygienic thermal processing, these cleaning operations include full cleaning-in-place (CIP), which restores equipment to near-clean conditions, and shorter aseptic intermediate cleaning (AIC), which partially removes deposits between production periods. Conventional HEN synthesis usually optimizes network topology and exchanger sizing under clean steady-state conditions, while fouling and cleaning studies often consider operation for a fixed network. As a result, the interaction between heat-recovery design, fouling accumulation, cleaning policy, production availability, and economic performance is not captured consistently. The key novelty of this work is the coupling of utility-substage HEN synthesis with event-based fouling and cleaning scheduling.A two-step mixed-integer nonlinear programming framework is developed and demonstrated using ultra-high-temperature milk processing as a representative fouling-prone hygienic thermal process. In Step 1, network topology, utility placement, and heat-transfer area are optimized using a modified stage-wise superstructure. In Step 2, the fixed network is evaluated over a one-week horizon by scheduling production, AIC, and CIP events. Fouling increases the required heat-transfer area from 370.4 m² under clean conditions to 743.6 m² under fully fouled conditions, mainly in internal heat-recovery exchangers. The OneStep configuration reduces external utility consumption by approximately 8%, but requires additional heat-transfer area. Scheduling results show that cleaning policy strongly affects production availability and profitability, with hybrid AIC–CIP operation providing a practical compromise between production continuity, profitability, and hygienic assurance.
- 9 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHeat Exchanger Network Optimization and Cleaning Scheduling under Fouling: Application to UHT Dairy Heat Recovery
Heat exchanger networks (HENs) are widely used to reduce utility consumption in industrial thermal processes, but their performance is often limited by fouling and cleaning-related production interruptions. In hygienic thermal processing, these cleaning operations include full cleaning-in-place (CIP), which restores equipment to near-clean conditions, and shorter aseptic intermediate cleaning (AIC), which partially removes deposits between production periods. Conventional HEN synthesis usually optimizes network topology and exchanger sizing under clean steady-state conditions, while fouling and cleaning studies often consider operation for a fixed network. As a result, the interaction between heat-recovery design, fouling accumulation, cleaning policy, production availability, and economic performance is not captured consistently. The key novelty of this work is the coupling of utility-substage HEN synthesis with event-based fouling and cleaning scheduling.A two-step mixed-integer nonlinear programming framework is developed and demonstrated using ultra-high-temperature milk processing as a representative fouling-prone hygienic thermal process. In Step 1, network topology, utility placement, and heat-transfer area are optimized using a modified stage-wise superstructure. In Step 2, the fixed network is evaluated over a one-week horizon by scheduling production, AIC, and CIP events. Fouling increases the required heat-transfer area from 370.4 m² under clean conditions to 743.6 m² under fully fouled conditions, mainly in internal heat-recovery exchangers. The OneStep configuration reduces external utility consumption by approximately 8%, but requires additional heat-transfer area. Scheduling results show that cleaning policy strongly affects production availability and profitability, with hybrid AIC–CIP operation providing a practical compromise between production continuity, profitability, and hygienic assurance.
- Open Access
- 25 October 2025
- Published by Elsevier in Food and Bioproducts Processing
- Vol. 154, 489-499
Prediction of major pressure losses pumping non-Newtonian foods and beverages – The role of uncertainty propagation for power law fluids
- 25 October 2025
- Published by Elsevier in Food and Bioproducts Processing
- Vol. 154, 489-499
Open AccessPrediction of major pressure losses pumping non-Newtonian foods and beverages – The role of uncertainty propagation for power law fluids
- Open Access
- 21 October 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 321
Cleaning of a soluble soil layer by flow over a flat surface: an example of a Stefan-Graetz problem
- 21 October 2025
- Published by Elsevier in Chemical Engineering Science
- Vol. 321
Open AccessCleaning of a soluble soil layer by flow over a flat surface: an example of a Stefan-Graetz problem
- Open Access
- 29 September 2025
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 61 (10) , 1-10
Experimental and numerical investigations of cleaning based on fundamental modelling of mass transfer
The removal of a model food soil, a soluble coffee extract, from stainless steel plates by the passage of cold water has been investigated for two geometries: in a radial flow cell, where the flow is laminar and steady (but not simple), and in a rectangular duct where the flow is turbulent and fully developed. The rate of removal is assumed to be controlled by diffusion in the liquid phase, i.e. convective mass transfer where the liquid is moving. The experimental cleaning data, based on the local time to clean, are compared with detailed numerical models, where CFD simulations provide the velocity field for the mass transport equation. The diffusion coefficient for the coffee soil is determined separately by two different methods. The radial flow cell exhibits two cleaning fronts, related to the presence of recirculation zones, while cleaning in the duct features striations associated with periodic turbulence patterns. The results indicate that modelling even the simplest removal mechanism is not straightforward.
- 29 September 2025
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 61 (10) , 1-10
Open AccessExperimental and numerical investigations of cleaning based on fundamental modelling of mass transfer
The removal of a model food soil, a soluble coffee extract, from stainless steel plates by the passage of cold water has been investigated for two geometries: in a radial flow cell, where the flow is laminar and steady (but not simple), and in a rectangular duct where the flow is turbulent and fully developed. The rate of removal is assumed to be controlled by diffusion in the liquid phase, i.e. convective mass transfer where the liquid is moving. The experimental cleaning data, based on the local time to clean, are compared with detailed numerical models, where CFD simulations provide the velocity field for the mass transport equation. The diffusion coefficient for the coffee soil is determined separately by two different methods. The radial flow cell exhibits two cleaning fronts, related to the presence of recirculation zones, while cleaning in the duct features striations associated with periodic turbulence patterns. The results indicate that modelling even the simplest removal mechanism is not straightforward.
- Open Access
- 12 November 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 139
One test to predict them all: Rheological characterization of complex fluids via artificial neural network
- 12 November 2024
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 139
Open AccessOne test to predict them all: Rheological characterization of complex fluids via artificial neural network
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Scaling laws for near-wall flows of thixo-elasto-viscoplastic fluids in a millifluidic channel
Thixo-elasto-viscoplastic (TEVP) fluids are very complex fluids. In addition to elasticity and viscoplasticity, they exhibit thixotropy, i.e., time-dependent rheology due to breakdown and recovery of internal structures at different length- and timescales. General and consistent methods for a priori flow prediction of TEVP fluids based on rheological characteristics are yet to be developed. We report a combined study of the rheology and flow of 18 samples of different TEVP fluids (three yogurts and three concentrations of Laponite and Carbopol, respectively, in water in both the unstirred and a stirred state). The rheology is determined both with standard protocols and with an ex situ protocol aiming at reproducing the shear history of the fluid in the flow. Micrometer resolution flow measurements in a millimeter scale rectangular duct are performed with Doppler Optical Coherence Tomography (D-OCT). As expected, the results show the existence of a plug flow region for samples with sufficiently high yield stress. At low flow rates, the plug extends almost all the way to the wall and the extent of the plug decreases not only with increased flow rate but also with increased thixotropy. The ex situ rheology protocol enables estimation of the shear rate and shear stress close to the wall, making it possible to identify two scaling laws that relates four different non-dimensional groups quantifying the key properties wall-shear stress and slip velocity. The scaling laws are suggested as an ansatz for a priori prediction of the near-wall flow of TEVP fluids based on shear flow-curves obtained with a rheometer.
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Open AccessScaling laws for near-wall flows of thixo-elasto-viscoplastic fluids in a millifluidic channel
Thixo-elasto-viscoplastic (TEVP) fluids are very complex fluids. In addition to elasticity and viscoplasticity, they exhibit thixotropy, i.e., time-dependent rheology due to breakdown and recovery of internal structures at different length- and timescales. General and consistent methods for a priori flow prediction of TEVP fluids based on rheological characteristics are yet to be developed. We report a combined study of the rheology and flow of 18 samples of different TEVP fluids (three yogurts and three concentrations of Laponite and Carbopol, respectively, in water in both the unstirred and a stirred state). The rheology is determined both with standard protocols and with an ex situ protocol aiming at reproducing the shear history of the fluid in the flow. Micrometer resolution flow measurements in a millimeter scale rectangular duct are performed with Doppler Optical Coherence Tomography (D-OCT). As expected, the results show the existence of a plug flow region for samples with sufficiently high yield stress. At low flow rates, the plug extends almost all the way to the wall and the extent of the plug decreases not only with increased flow rate but also with increased thixotropy. The ex situ rheology protocol enables estimation of the shear rate and shear stress close to the wall, making it possible to identify two scaling laws that relates four different non-dimensional groups quantifying the key properties wall-shear stress and slip velocity. The scaling laws are suggested as an ansatz for a priori prediction of the near-wall flow of TEVP fluids based on shear flow-curves obtained with a rheometer.