GHGuoping Huang

Guoping Huang

*This is an algorithmically generated author record based on publicly available information.

Guoping Huang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Biao Liu

    College of Materials Science and Technology, Jiangsu Key Laboratory of Materials and Technology for Energy Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China

    1 shared publication
  • Feng Qian

    College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, People’s Republic of China

    1 shared publication
  • Honglie Shen

    College of Materials Science and Technology, Jiangsu Key Laboratory of Materials and Technology for Energy Conversion, Nanjing University of Aeronautics and Astronautics, Nanjing, People’s Republic of China

    1 shared publication
  • Juan Hong

    College of Mechanical Engineering, Yancheng Institute of Technology, Yancheng, Jiangsu 224051, People’s Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Improvement of Laser-Induced Damage on High-Efficiency Solar Cells via Top-Hat Beam Ablation

    by Feng Qian, Honglie Shen, Guoping Huang, Biao Liu, Juan Hong

    An important challenge in industrial laser ablation is laser-induced damage. In this study, reduced damage was achieved through the transition of the laser distribution from a Gaussian beam to a top-hat beam using diffractive optical elements (DOE), which overcome inhomogeneous irradiation. The higher peak fluence of a Gaussian beam far exceeded the ablation threshold and led to severely melted silicon at a higher depth covering the polished texture. The top-hat beam, with uniform irradiation, had a superior ablation characteristic and created a uniform square opening with the shallow melted silicon in the lift-off process. Thus, its effective minor carrier lifetime was 15.35% less at an ablated area fraction of 2% after re-passivation because of the decreased damage. After optimizing the ablation pattern with a top-hat beam, the local contacts improved the average open-circuit voltage (Voc) and short-circuit current (Isc) values of the cells due to the decreased damage and the uniform openings, but the damage induced by a Gaussian beam was too deep and can be partly restored under back surface field (BSF) formation. The overall increment in Isc and Voc enhanced the average efficiency by 0.05% of the absolute value for the PERC cells and 0.03% of the absolute value for bi-facial PERC cells.