Chenzhao Ben
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chenzhao Ben has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Honghai Shen
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Huishi Cheng
Changchun Institute of Optics, Fine Mechanics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Lingtong Meng
Key Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Ping Jia
State Key Laboratory of Dynamic Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
2 shared publications - Xiao Yu
Key Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication
Latest Publications
- Open Access
- 23 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1838
A Phase Correction Model for Fourier Transform Spectroscopy
In Fourier transform spectroscopy (FTS), the conventional Mertz method is commonly used to correct phase errors of recovered spectra, but it performs poorly in correcting nonlinear phase errors. This paper proposes a phase correlation method–all-pass filter (PCM-APF) model to correct phase errors. In this model, the proposed improved phase correlation method can correct linear phase errors, and all-pass filters are applied to correct the residual nonlinear phase errors. The optimization algorithm for the digital all-pass filters employs an improved algorithm which combines the subtraction-average-based optimizer (SABO) and the golden sine algorithm (Gold-SA). The proposed PCM-APF model demonstrates high correction precision, and the optimization algorithm for the filters converges faster than traditional intelligent optimization algorithms.
- 23 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1838
Open AccessA Phase Correction Model for Fourier Transform Spectroscopy
In Fourier transform spectroscopy (FTS), the conventional Mertz method is commonly used to correct phase errors of recovered spectra, but it performs poorly in correcting nonlinear phase errors. This paper proposes a phase correlation method–all-pass filter (PCM-APF) model to correct phase errors. In this model, the proposed improved phase correlation method can correct linear phase errors, and all-pass filters are applied to correct the residual nonlinear phase errors. The optimization algorithm for the digital all-pass filters employs an improved algorithm which combines the subtraction-average-based optimizer (SABO) and the golden sine algorithm (Gold-SA). The proposed PCM-APF model demonstrates high correction precision, and the optimization algorithm for the filters converges faster than traditional intelligent optimization algorithms.
- Open Access
Stray Light Analysis and Suppression for an Infrared Fourier Imaging Spectrometer
To improve the accuracy of infrared radiation characteristics measurement in the aviation field, an infrared Fourier transform imaging spectrometer based on a double-swing solid angle reflector was designed. This imaging spectrometer operates in the 3–5 μm wavelength range and has a field of view of 1.7° × 1.7°. This article presents a comprehensive analysis of the system’s stray light and also studies the impact of external stray light on the imaging quality, along with the influence of internal stray light on the interference effects and the spectral resolution. It also present the design of a hood that suppresses the point source transmittance of the external stray light down to the order of 10−4. Based on this, we propose a method that incorporates the introduction of wedge and inclination angles. Additionally, a numerical range is provided for the addition of these angles on the beam splitter mirror and compensation plate. This ensures the effective suppression of any internal stray light. This study fills the gap in the knowledge about Fourier transform imaging spectrometers operating in the mid-infrared band for aviation applications, and proposes a suppression method suitable for interference systems, which is also suitable for Fourier transform imaging spectrometers based on other types of interferometers. This study broadens the application field of Fourier transform imaging spectrometers in stray light, and has great significance to promote the development of Fourier transform imaging spectrometer.
Open AccessStray Light Analysis and Suppression for an Infrared Fourier Imaging Spectrometer
To improve the accuracy of infrared radiation characteristics measurement in the aviation field, an infrared Fourier transform imaging spectrometer based on a double-swing solid angle reflector was designed. This imaging spectrometer operates in the 3–5 μm wavelength range and has a field of view of 1.7° × 1.7°. This article presents a comprehensive analysis of the system’s stray light and also studies the impact of external stray light on the imaging quality, along with the influence of internal stray light on the interference effects and the spectral resolution. It also present the design of a hood that suppresses the point source transmittance of the external stray light down to the order of 10−4. Based on this, we propose a method that incorporates the introduction of wedge and inclination angles. Additionally, a numerical range is provided for the addition of these angles on the beam splitter mirror and compensation plate. This ensures the effective suppression of any internal stray light. This study fills the gap in the knowledge about Fourier transform imaging spectrometers operating in the mid-infrared band for aviation applications, and proposes a suppression method suitable for interference systems, which is also suitable for Fourier transform imaging spectrometers based on other types of interferometers. This study broadens the application field of Fourier transform imaging spectrometers in stray light, and has great significance to promote the development of Fourier transform imaging spectrometer.