Milan Veljković
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Milan Veljković has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Martin Paul Nijgh
PhD Candidate Delft University of Technology
4 shared publications - Marko Pavlović
Delft Univ. of Technology
3 shared publications - Carlos Rebelo
University of Coimbra
2 shared publications - Henk Kolstein
Faculty of Civil Engineering and Geosciences, Delft University of Technology, Delft 2628CN, The Netherlands
2 shared publications - Ioan Andrei Gîrbacea
Master Student Delft University of Technology
2 shared publications - Alina Gritsenko
Delft University of Technology, Faculty of Civil Engineering and Geosciences The Netherlands
1 shared publication
Latest Publications
- 15 August 2022
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 29 (4) , 1382-1393
Structural Steel Joints with Bolts in Threaded Holes
The application of tubular columns in steel structures offers many advantages. However, this potential has not been fully utilized due to a lack of access for the installation of standard bolts in end-plate beam-to-column joints. Blind bolts are an a...
- 15 August 2022
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 29 (4) , 1382-1393
Structural Steel Joints with Bolts in Threaded Holes
The application of tubular columns in steel structures offers many advantages. However, this potential has not been fully utilized due to a lack of access for the installation of standard bolts in end-plate beam-to-column joints. Blind bolts are an a...
- 24 January 2022
- Published by Wiley in Steel Construction
- Vol. 15 (1) , 13-25
Introducing the C1 Wedge Connection
Increasing loads on the connections of tubular towers that support wind turbines are making the traditional bolted L‐flange more challenging to design, while the large mass of components and tools make installation challenging from a safety perspective. The C1 Wedge Connection is a symmetrical connection between tubular sections. The connection consists of a cylindrical lower flange and a fork‐shaped upper flange that slides over the lower flange. Both flanges have radial elongated holes distributed along the perimeter allowing the C1 fasteners to pull the two flanges together. The fastener assembly of the C1 Wedge Connection uses a small, horizontally placed bolt to pull two wedges together. The wedges transform and magnify the horizontal bolt force into a larger preload between the flanges by pulling them together. The orientation of the bolt in the fastener prevents significant load fluctuations under external loading. As a result, unlike a bolted L‐flange, the C1 Wedge Connection is less susceptible to preload loss, thereby eliminating the need for regular maintenance and inspection. The scalability of the C1 Wedge Connection makes it suitable for larger loads. These larger loads are expected with increasing size of wind turbines and when connections are used in more demanding locations such as hurricane and seismic conditions or where connections are subjected to high dynamic loads caused by extreme wave conditions or on floating foundations.
- 24 January 2022
- Published by Wiley in Steel Construction
- Vol. 15 (1) , 13-25
Introducing the C1 Wedge Connection
Increasing loads on the connections of tubular towers that support wind turbines are making the traditional bolted L‐flange more challenging to design, while the large mass of components and tools make installation challenging from a safety perspective. The C1 Wedge Connection is a symmetrical connection between tubular sections. The connection consists of a cylindrical lower flange and a fork‐shaped upper flange that slides over the lower flange. Both flanges have radial elongated holes distributed along the perimeter allowing the C1 fasteners to pull the two flanges together. The fastener assembly of the C1 Wedge Connection uses a small, horizontally placed bolt to pull two wedges together. The wedges transform and magnify the horizontal bolt force into a larger preload between the flanges by pulling them together. The orientation of the bolt in the fastener prevents significant load fluctuations under external loading. As a result, unlike a bolted L‐flange, the C1 Wedge Connection is less susceptible to preload loss, thereby eliminating the need for regular maintenance and inspection. The scalability of the C1 Wedge Connection makes it suitable for larger loads. These larger loads are expected with increasing size of wind turbines and when connections are used in more demanding locations such as hurricane and seismic conditions or where connections are subjected to high dynamic loads caused by extreme wave conditions or on floating foundations.
- 1 January 2022
- Published by International Association for Bridge and Structural Engineering (IABSE)
- p. 810-819
Behavior of Orthotropic Steel-UHPC Composite Bridge Deck under Cyclic Loading
Conference paper written by Zhanchong Shi, Qingtian Su and Milan Veljković presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022.
- 1 January 2022
- Published by International Association for Bridge and Structural Engineering (IABSE)
- p. 810-819
Behavior of Orthotropic Steel-UHPC Composite Bridge Deck under Cyclic Loading
Conference paper written by Zhanchong Shi, Qingtian Su and Milan Veljković presented at IABSE Symposium: Challenges for Existing and Oncoming Structures, Prague, Czech Republic, 25-27 May 2022.
- Open Access
- 1 June 2021
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 73 (05) , 453-468
Experimental investigation of preload losses in high strength bolts under cyclic loading
- 1 June 2021
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 73 (05) , 453-468
Open AccessExperimental investigation of preload losses in high strength bolts under cyclic loading
- 7 November 2017
- Published by Wiley in Steel Construction
- Vol. 10 (4) , 287-294
Behaviour of double shear connections with injection bolts
The RFCS project SIROCO (2014–17) included research on the further development and optimization of double shear connections with injection bolts to achieve slip‐ and creep‐resistant bolted connections considering various influencing parameters. The type of resin, the curing condition of the resin, the geometrical and mechanical characteristics of the connection and the type of loading were studied. Results showed, for example, that of the five epoxy resins investigated, only RenGel SW404 + HY2404 (Araldite) fulfils the requirements given in Eurocode 3. A bearing stress of 175 MPa is safely allowable in the long‐term without exceeding imposed deformation limits.
- 7 November 2017
- Published by Wiley in Steel Construction
- Vol. 10 (4) , 287-294
Behaviour of double shear connections with injection bolts
The RFCS project SIROCO (2014–17) included research on the further development and optimization of double shear connections with injection bolts to achieve slip‐ and creep‐resistant bolted connections considering various influencing parameters. The type of resin, the curing condition of the resin, the geometrical and mechanical characteristics of the connection and the type of loading were studied. Results showed, for example, that of the five epoxy resins investigated, only RenGel SW404 + HY2404 (Araldite) fulfils the requirements given in Eurocode 3. A bearing stress of 175 MPa is safely allowable in the long‐term without exceeding imposed deformation limits.
03.16: Multiplanar K‐joints on cold‐formed open sections: An experimental study with high strength steels
The design, laboratory investigation and main results of an experimental programme on the joints of an innovative 3D truss made of high strength steel (HSS) is presented. An entire truss of triangular cross‐section was fabricated (two compression chords and a single tension chord) to provide realistic loading conditions. Both compression and tension chords were fabricated by cold forming hot‐rolled HSS plates by means of press braking. The chords were as follows: — an open angle‐type profile with 45° contained angle as tension chord (U‐chord), — a semi‐closed octagonal profile made of 3 sectors bolted along their length every 1.2 diameters as compression chords (P‐chord). The focus of this study is on the tension chords joints where a pair of tension and a pair of compression diagonals converge. Joints were tested to ultimate load by introducing shear to one bay of the truss at a time. Two design approaches for the joints were tested resulting in four individual tests.Ultimate load levels, stiffness and failure modes varied between the considered joint configurations. Stiffening increased the ultimate load by as much as 170% of that of the unstiffened version achieving higher utilisation of the tension chord, thus making more efficient use of HSS. The stiffness loss at loads close to failure varied between 60% – 80%. Two distinctive failure modes were observed, one caused by cracking of the welds connecting the diagonal's gusset plates to the tension chord while the second by cross‐section tensile fracture of the circular hollow section (CHS) diagonal.
03.16: Multiplanar K‐joints on cold‐formed open sections: An experimental study with high strength steels
The design, laboratory investigation and main results of an experimental programme on the joints of an innovative 3D truss made of high strength steel (HSS) is presented. An entire truss of triangular cross‐section was fabricated (two compression chords and a single tension chord) to provide realistic loading conditions. Both compression and tension chords were fabricated by cold forming hot‐rolled HSS plates by means of press braking. The chords were as follows: — an open angle‐type profile with 45° contained angle as tension chord (U‐chord), — a semi‐closed octagonal profile made of 3 sectors bolted along their length every 1.2 diameters as compression chords (P‐chord). The focus of this study is on the tension chords joints where a pair of tension and a pair of compression diagonals converge. Joints were tested to ultimate load by introducing shear to one bay of the truss at a time. Two design approaches for the joints were tested resulting in four individual tests.Ultimate load levels, stiffness and failure modes varied between the considered joint configurations. Stiffening increased the ultimate load by as much as 170% of that of the unstiffened version achieving higher utilisation of the tension chord, thus making more efficient use of HSS. The stiffness loss at loads close to failure varied between 60% – 80%. Two distinctive failure modes were observed, one caused by cracking of the welds connecting the diagonal's gusset plates to the tension chord while the second by cross‐section tensile fracture of the circular hollow section (CHS) diagonal.