Sangjin Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sangjin Lee has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Geonwoo Baek
School of Electrical and Electronic Engineering, Yonsei University, Seoul Korea (the Republic of)
3 shared publications - Junseong Kim
Facility for Rare Isotope Beams, East Lansing, MI, USA
3 shared publications - Tae Kuk Ko
School of Electrical and Electronic Engineering, Yonsei University, Seoul, South Korea
3 shared publications - Zhan Zhang
Institute of Energy, Hefei Comprehensive National Science Center (Anhui Energy Laboratory), Hefei, People’s Republic of China
3 shared publications - Shaoqing Wei
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, People’s Republic of China
2 shared publications - Woo Seung Lee
Korea Basic Science Institute, Cheongju-si, South Korea
2 shared publications
Latest Publications
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Minimum Volume Optimal Design Method of Hybrid MRI Magnet
The purpose of this paper is to present a minimum volume optimal design method of hybrid magnetic resonance imaging (MRI) magnet using field superposition. The hybrid MRI magnet made by high-temperature superconductor (HTS) and low-temperature superconductor (LTS) is the optimal approach of producing higher magnetic field, which also reduces volume than LTS. In this study, the field superposition theory combined with linear programming and nonlinear optimization is introduced in advance to get minimum volume. Considering the different advantages of LTS magnets and HTS magnets, three hybrid MRI magnet configurations are introduced: (1) HTS insert and LTS outsert: (2) Minimum HTS magnet under LTS magnet: (3) Minimum LTS magnet under HTS magnet. In addition, the homogeneity over the central sphere volume and the scope of 5 Gauss fringe field are considered in actively shielding MRI design. Finally, the three different configurations are compared and a 7 T hybrid actively shielding MRI magnet is presented. The designed magnet homogeneity and 5 Gauss fringe field are validated by finite element simulation method, which illustrates the efficiency and the flexibility of the proposed optimal method. This method can also be used for other higher field hybrid magnet design
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Minimum Volume Optimal Design Method of Hybrid MRI Magnet
The purpose of this paper is to present a minimum volume optimal design method of hybrid magnetic resonance imaging (MRI) magnet using field superposition. The hybrid MRI magnet made by high-temperature superconductor (HTS) and low-temperature superconductor (LTS) is the optimal approach of producing higher magnetic field, which also reduces volume than LTS. In this study, the field superposition theory combined with linear programming and nonlinear optimization is introduced in advance to get minimum volume. Considering the different advantages of LTS magnets and HTS magnets, three hybrid MRI magnet configurations are introduced: (1) HTS insert and LTS outsert: (2) Minimum HTS magnet under LTS magnet: (3) Minimum LTS magnet under HTS magnet. In addition, the homogeneity over the central sphere volume and the scope of 5 Gauss fringe field are considered in actively shielding MRI design. Finally, the three different configurations are compared and a 7 T hybrid actively shielding MRI magnet is presented. The designed magnet homogeneity and 5 Gauss fringe field are validated by finite element simulation method, which illustrates the efficiency and the flexibility of the proposed optimal method. This method can also be used for other higher field hybrid magnet design
- 10 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Effect of Screening Current Induced Field on Field Quality of an Air-Core HTS Quadrupole Magnet
An air-core high-temperature superconducting (HTS) quadrupole magnet has many advantages for heavy-ion accelerator applications due to the elimination of the iron-core of a conventional HTS quadrupole magnet. It is compact, lightweight, and free of hysteresis of a ferromagnetic material. In our previous study, an air-core HTS quadrupole magnet of 3.0 T/m field gradient was designed. It was composed of eight double-pancake racetrack coils, each wound using 4-mm wide HTS tapes. In the magnet design, a uniform current density was assumed in the HTS tapes. However, in the HTS racetrack coils, magnetization currents are induced by the magnetic field component perpendicular to the tapes, and the magnetization currents generate the so-called screening current induced field (SCIF). For the quadrupole magnet, the SCIF could be critical to the field quality of the magnet. In this study, the current density distribution was calculated considering the magnetization current. Furthermore, the effect of the SCIF on the field quality of the magnet is analyzed and discussed.
- 10 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Effect of Screening Current Induced Field on Field Quality of an Air-Core HTS Quadrupole Magnet
An air-core high-temperature superconducting (HTS) quadrupole magnet has many advantages for heavy-ion accelerator applications due to the elimination of the iron-core of a conventional HTS quadrupole magnet. It is compact, lightweight, and free of hysteresis of a ferromagnetic material. In our previous study, an air-core HTS quadrupole magnet of 3.0 T/m field gradient was designed. It was composed of eight double-pancake racetrack coils, each wound using 4-mm wide HTS tapes. In the magnet design, a uniform current density was assumed in the HTS tapes. However, in the HTS racetrack coils, magnetization currents are induced by the magnetic field component perpendicular to the tapes, and the magnetization currents generate the so-called screening current induced field (SCIF). For the quadrupole magnet, the SCIF could be critical to the field quality of the magnet. In this study, the current density distribution was calculated considering the magnetization current. Furthermore, the effect of the SCIF on the field quality of the magnet is analyzed and discussed.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Experimental Test of the Magnetic Field Active Shimming Method for Air-Core HTS Quadruple Magnet
Quadruple magnets are used as superconducting magnets in ac-celerator systems and to focus the accelerated beam particles. Therefore, studies are being conducted to implement HTS quad-ruple magnets in hot cell regions that possess high heat loads in accelerator systems. Additionally, studies on air-core HTS quad-ruple magnet (AHQM), which do not possess an iron yoke, are also being carried out. This magnet is suitable for the use in hot cell regions and generates a higher magnetic field. Further, mag-netic field characteristic of the magnet are linear with respect to the operating current. However, the magnetic field of an AHQM can be the sensitively affected by manufacturing and assembly errors because the iron yoke is removed. After the manufacturing of the magnet, magnetic field shimming is used to compensate for magnetic field errors. This paper presents the optimum design and process for the copper wire bunch active shim (CBAS) meth-od. Furthermore, a test model of the CBAS method is constructed based on the design, and the characteristics and applicability of the proposed model are analyzed.
- 13 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Experimental Test of the Magnetic Field Active Shimming Method for Air-Core HTS Quadruple Magnet
Quadruple magnets are used as superconducting magnets in ac-celerator systems and to focus the accelerated beam particles. Therefore, studies are being conducted to implement HTS quad-ruple magnets in hot cell regions that possess high heat loads in accelerator systems. Additionally, studies on air-core HTS quad-ruple magnet (AHQM), which do not possess an iron yoke, are also being carried out. This magnet is suitable for the use in hot cell regions and generates a higher magnetic field. Further, mag-netic field characteristic of the magnet are linear with respect to the operating current. However, the magnetic field of an AHQM can be the sensitively affected by manufacturing and assembly errors because the iron yoke is removed. After the manufacturing of the magnet, magnetic field shimming is used to compensate for magnetic field errors. This paper presents the optimum design and process for the copper wire bunch active shim (CBAS) meth-od. Furthermore, a test model of the CBAS method is constructed based on the design, and the characteristics and applicability of the proposed model are analyzed.
- 29 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
A Study on the Sextupole Design with Iron Yoke Inside Solenoids for 56 GHz ECR Ion Sources
The third generation of electron cyclotron resonance (ECR) ion sources is in operation or under development in the world. The fourth generation ECR ion sources are expected to operate at a heating radio frequency greater than 40 GHz, requiring a higher confinement field. Such requirements provide the motivation to design the structure of the fourth generation ECR ion sources. The Nb3Sn wire, which can generate fields in the 10-20 T range, is considered to construct the magnet coil analyzed in this study. First, for both solenoid-in-sextupole structure and sextupole-in-solenoid structure, the critical current of materials and the local magnetic field are analyzed and compared. By the comparison, sextupole-in-solenoid structure is selected to construct sextupole magnet for 56 GHz ECR ion source. Considering the characteristics of the wire and the Lorentz force on sextupole ends, iron yoke is considered to be added around sextupole to provide a structure for the sextupole coils. Then, the confinement fields and the safety margin of the wire are analyzed and compared using models with and without the iron yoke. Finally, a design of the sextupole with a shorter iron yoke is presented in this paper. With the suggested sextupole design, the length of the sextupole and the total size of the ECR ion source can be reduced.
- 29 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
A Study on the Sextupole Design with Iron Yoke Inside Solenoids for 56 GHz ECR Ion Sources
The third generation of electron cyclotron resonance (ECR) ion sources is in operation or under development in the world. The fourth generation ECR ion sources are expected to operate at a heating radio frequency greater than 40 GHz, requiring a higher confinement field. Such requirements provide the motivation to design the structure of the fourth generation ECR ion sources. The Nb3Sn wire, which can generate fields in the 10-20 T range, is considered to construct the magnet coil analyzed in this study. First, for both solenoid-in-sextupole structure and sextupole-in-solenoid structure, the critical current of materials and the local magnetic field are analyzed and compared. By the comparison, sextupole-in-solenoid structure is selected to construct sextupole magnet for 56 GHz ECR ion source. Considering the characteristics of the wire and the Lorentz force on sextupole ends, iron yoke is considered to be added around sextupole to provide a structure for the sextupole coils. Then, the confinement fields and the safety margin of the wire are analyzed and compared using models with and without the iron yoke. Finally, a design of the sextupole with a shorter iron yoke is presented in this paper. With the suggested sextupole design, the length of the sextupole and the total size of the ECR ion source can be reduced.
- 26 August 2014
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 28 (2) , 625-628
Minimum Volume Solenoid Magnet Design with a Rectangular Cross Section Which Has the Specific Inductance Value
- 26 August 2014
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 28 (2) , 625-628
Minimum Volume Solenoid Magnet Design with a Rectangular Cross Section Which Has the Specific Inductance Value
- 30 September 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 24 (1-2) , 1037-1043
A Ferromagnetic Shimming Method for NMR/MRI Magnets Adopting Two Consecutive Optimization Techniques: Linear Programming and Evolution Strategy
- 30 September 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 24 (1-2) , 1037-1043
A Ferromagnetic Shimming Method for NMR/MRI Magnets Adopting Two Consecutive Optimization Techniques: Linear Programming and Evolution Strategy