FSFrancesco Sarti

Francesco Sarti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francesco Sarti has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fuse-Type External Replaceable Dissipaters: Experimental Program and Numerical Modeling

    by Francesco Sarti, Alessando Palermo, Stefano Pampanin

    The paper presents the experimental and numerical study of a mild steel replaceable dissipation device. The dissipater is made of a milled-down mild steel bar that is confined by a steel tube filled with either grout or epoxy. The use of a reduced area concentrates yielding and plastic straining over a defined length while the tube prevents buckling. The device has been widely adopted in posttensioned rocking systems, and extensive experimental research was carried out on wall and beam-column subassemblies using this external dissipater. As part of those experimental programs, some component testing was carried out; nevertheless, a more comprehensive study was necessary to cover a wider range of geometric and mechanical parameters. The main objective of this research was to calibrate and suggest design parameters to support the design of the dissipation device. The paper shows a comprehensive experimental program under quasi-static cyclic loading carried out with varying geometrical parameters. Th...


  • Determination of the seismic performance factors for post‐tensioned rocking timber wall systems

    by Francesco Sarti, Alessandro Palermo, Stefano Pampanin, Jeffrey Berman

    Summary: Post‐tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re‐centering and energy dissipative contributions respectively by using post‐tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post‐earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post‐tensioned rocking LVL walls using the FEMA P‐695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non‐linear quasi‐static analyses were carried out to evaluate the system over‐strength factor; moreover, non‐linear time history analyses were performed using the incremental dynamic analysis concept to assess the collapse of each building. From the results of quasi‐static and dynamic analyses the response modification factor, R, system over‐strength factor, Ω0, and deflection amplification factor, Cd, values of, respectively, 7, 3.5 and 7.5 are recommended. Copyright © 2016 John Wiley & Sons, Ltd.


  • Development and Testing of an Alternative Dissipative Posttensioned Rocking Timber Wall with Boundary Columns

    by Francesco Sarti, Alessandro Palermo, Stefano Pampanin

    The unbonded posttensioned rocking and dissipative technology was first developed as the main outcome of the PREcast seismic structural systems (PRESSS) Program in the United States. After the first developments and significant refinement, the technology was extended to steel and, more recently, timber structures. The timber version, referred to as prestressed laminated (Pres-Lam) system can be either implemented for timber walls (single or coupled) or frames or a combination of the above, with unbonded posttensioning and supplemental dissipation devices. In unbonded posttensioned dissipative wall systems a combination of recentering capacity and energy dissipation leads to a controlled rocking mechanism, which develops a gap opening at the wall base. This generates an uplift displacement that is transferred to the floor diaphragm. This vertical displacement incompatibility can represent a potential issue if the connection detailing between floor and lateral resisting system is not designed proper...