Madhumita B. Ray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Madhumita B. Ray has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A. S. Mujumdar
Department of Mechanical Engineering , National University of Singapore , Singapore
1 shared publicationArun S. Mujumdar
Department of Chemical and Environmental Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117576
1 shared publicationFeiyan Chen
Department of Chemical and Environmental Engineering, National University of Singapore
1 shared publicationGopalan Ravi
Department of Chemical and Environmental Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117576
1 shared publicationH T Yang
Department of Chemical and Environmental Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore 117576
1 shared publicationQuan Yang
Department of Chemical and Environmental Engineering , National University of Singapore
1 shared publication
Latest Publications
- 20 December 2004
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 47 (2) , 147-164
HEAT TRANSFER IN MULTIPLE-TURBULENT-SLOT IMPINGING JETS OF GAS–PARTICLE SUSPENSIONS
The heat transfer in a dilute gas–particle suspension flow through multiple-slot impinging jets has been numerically investigated employing a new Eulerian-Lagrangian model. The two-phase turbulent flow is simulated using the standard k–ϵ model and Lagrangian particle tracking, which includes coupling terms to simulate the fluid–particle interactions. The numerical results are compared with the available experimental data. Good agreement between the experiment and simulation is obtained only if the conduction heat transfer due to particle–wall collisions is considered in the model. Effects of particle loading ratio, wall reflection coefficient, and wall materials properties on the heat transfer rate are discussed.
- 20 December 2004
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 47 (2) , 147-164
HEAT TRANSFER IN MULTIPLE-TURBULENT-SLOT IMPINGING JETS OF GAS–PARTICLE SUSPENSIONS
The heat transfer in a dilute gas–particle suspension flow through multiple-slot impinging jets has been numerically investigated employing a new Eulerian-Lagrangian model. The two-phase turbulent flow is simulated using the standard k–ϵ model and Lagrangian particle tracking, which includes coupling terms to simulate the fluid–particle interactions. The numerical results are compared with the available experimental data. Good agreement between the experiment and simulation is obtained only if the conduction heat transfer due to particle–wall collisions is considered in the model. Effects of particle loading ratio, wall reflection coefficient, and wall materials properties on the heat transfer rate are discussed.
- Open Access
- 1 October 2004
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 54 (10) , 1281-1292
Modeling of gas-phase photodegradation of chloroform and carbon tetrachloride.
The relationship between the irradiance in a photoreactor and the rate of photodegradation of organics is essential in the scaling-up of photoreactors to treat large volumes of air contaminated with organic pollutants. In this study, the analysis is adopted to compare results obtained from two different photoreactors. Initially, the applicability of two light models in calculating the irradiance in two photoreactors was evaluated. Thereafter, kinetic models of ultraviolet (UV) photooxidation of chloroform (CHCl3) and carbon tetrachloride (CCl4) from the archived literature were tested using experimental data under various operating conditions and different irradiances. Sensitivity analyses were conducted using different values of model parameters to determine the significance of each parameter on the photodegradation of the two chlorinated or-ganics. For compounds that undergo photolysis as a primary mode of degradation, the rate of photodegradation at low initial concentrations can be predicted easily by the following equation: d[C]/dt = −2.303I ave,λελ φ λ[C]. Although the photodegradation of chlorinated organic compounds in dry and humid air can be predicted well, it is difficult to predict the Cl' sensitized oxidation occurring at high initial concentrations. A good agreement between the simulated and experimental data provides a sound basis for the design of large-scale reactors.
- 1 October 2004
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 54 (10) , 1281-1292
Open AccessModeling of gas-phase photodegradation of chloroform and carbon tetrachloride.
The relationship between the irradiance in a photoreactor and the rate of photodegradation of organics is essential in the scaling-up of photoreactors to treat large volumes of air contaminated with organic pollutants. In this study, the analysis is adopted to compare results obtained from two different photoreactors. Initially, the applicability of two light models in calculating the irradiance in two photoreactors was evaluated. Thereafter, kinetic models of ultraviolet (UV) photooxidation of chloroform (CHCl3) and carbon tetrachloride (CCl4) from the archived literature were tested using experimental data under various operating conditions and different irradiances. Sensitivity analyses were conducted using different values of model parameters to determine the significance of each parameter on the photodegradation of the two chlorinated or-ganics. For compounds that undergo photolysis as a primary mode of degradation, the rate of photodegradation at low initial concentrations can be predicted easily by the following equation: d[C]/dt = −2.303I ave,λελ φ λ[C]. Although the photodegradation of chlorinated organic compounds in dry and humid air can be predicted well, it is difficult to predict the Cl' sensitized oxidation occurring at high initial concentrations. A good agreement between the simulated and experimental data provides a sound basis for the design of large-scale reactors.
- 17 February 2003
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 78 (2-3) , 181-186
Modeling of electrostatic spray in a venturi scrubber
This paper summarizes the results of an investigation into the distribution of the droplets produced by electrostatic nozzles inside a Pease–Anthony venturi scrubber. The model simulates the flux distribution of charged droplets injected from an electrostatic nozzle in the scrubber under the combined influence of hydrodynamic and electric fields. The effects of operating parameters, such as gas velocity, diameter of the scrubbing droplets, charge‐to‐mass ratio and liquid‐to‐gas ratio, on the flux distribution of the water droplets in the throat of the scrubber are also investigated. The model takes into account initial liquid momentum, electric, hydrodynamic and gravitational forces, and eddy diffusion. The flux distribution of the scrubbing liquid in the presence of an electric field is much improved over a conventional scrubber, and the effect increases with the increase in charge‐to‐mass ratio. However, the effect of an electric field on the droplet flow pattern for small drops in a strong hydrodynamic field is negligible. Simulated results are in good agreement with the experimental data obtained in the laboratory.© 2003 Society of Chemical Industry
- 17 February 2003
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 78 (2-3) , 181-186
Modeling of electrostatic spray in a venturi scrubber
This paper summarizes the results of an investigation into the distribution of the droplets produced by electrostatic nozzles inside a Pease–Anthony venturi scrubber. The model simulates the flux distribution of charged droplets injected from an electrostatic nozzle in the scrubber under the combined influence of hydrodynamic and electric fields. The effects of operating parameters, such as gas velocity, diameter of the scrubbing droplets, charge‐to‐mass ratio and liquid‐to‐gas ratio, on the flux distribution of the water droplets in the throat of the scrubber are also investigated. The model takes into account initial liquid momentum, electric, hydrodynamic and gravitational forces, and eddy diffusion. The flux distribution of the scrubbing liquid in the presence of an electric field is much improved over a conventional scrubber, and the effect increases with the increase in charge‐to‐mass ratio. However, the effect of an electric field on the droplet flow pattern for small drops in a strong hydrodynamic field is negligible. Simulated results are in good agreement with the experimental data obtained in the laboratory.© 2003 Society of Chemical Industry
- 17 February 2003
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 78 (2-3) , 308-313
Multi‐objective optimization of venturi scrubbers using a three‐dimensional model for collection efficiency
- 17 February 2003
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 78 (2-3) , 308-313
Multi‐objective optimization of venturi scrubbers using a three‐dimensional model for collection efficiency
- 1 October 2001
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 79 (5) , 708-716
Collection efficiencies of various designs of post‐cyclone
- 1 October 2001
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 79 (5) , 708-716
Collection efficiencies of various designs of post‐cyclone