KAKavitha Arunachalam

Kavitha Arunachalam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kavitha Arunachalam has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence

    by K Arunachalam, P F Maccarini, O I Craciunescu, J L Schlorff, P R Stauffer

    The aim of this study was to investigate temperature and thermal dose distributions of thermobrachytherapy surface applicators (TBSAs) developed for concurrent or sequential high dose rate (HDR) brachytherapy and microwave hyperthermia treatment of chest wall recurrence and other superficial diseases. A steady-state thermodynamics model coupled with the fluid dynamics of a water bolus and electromagnetic radiation of the hyperthermia applicator is used to characterize the temperature distributions achievable with TBSAs in an elliptical phantom model of the human torso. Power deposited by 915 MHz conformal microwave array (CMA) applicators is used to assess the specific absorption rate (SAR) distributions of rectangular (500 cm(2)) and L-shaped (875 cm(2)) TBSAs. The SAR distribution in tissue and fluid flow distribution inside the dual-input dual-output (DIDO) water bolus are coupled to solve the steady-state temperature and thermal dose distributions of the rectangular TBSA (R-TBSA) for superficial tumor targets extending 10-15 mm beneath the skin surface. Thermal simulations are carried out for a range of bolus inlet temperature (T(b) = 38-43 degrees C), water flow rate (Q(b) = 2-4 L min(-1)) and tumor blood perfusion (omega(b) = 2-5 kg m(-3) s(-1)) to characterize their influence on thermal dosimetry. Steady-state SAR patterns of the R- and L-TBSA demonstrate the ability to produce conformal and localized power deposition inside the tumor target sparing surrounding normal tissues and nearby critical organs. Acceptably low variation in tissue surface cooling and surface temperature homogeneity was observed for the new DIDO bolus at a 2 L min(-1) water flow rate. Temperature depth profiles and thermal dose volume histograms indicate bolus inlet temperature (T(b)) to be the most influential factor on thermal dosimetry. A 42 degrees C water bolus was observed to be the optimal choice for superficial tumors extending 10-15 mm from the surface even under significant blood perfusion. Lower bolus temperature may be chosen to reduce the thermal enhancement ratio (TER) in the most sensitive skin where maximum radiation dose is delivered and to extend the thermal enhancement of radiation dose deeper. This computational study indicates that well-localized elevation of tumor target temperature to 40-44 degrees C can be accomplished by large surface-conforming TBSAs using appropriate selection of coupling bolus temperature.


  • Progress on thermobrachytherapy surface applicator for superficial tissue disease

    by Kavitha Arunachalam, Oana I. Craciunescu, Paolo F. Maccarini, Jaime L. Schlorff, Edward Markowitz, Paul R. Stauffer

    This work reports the ongoing development of a combination applicator for simultaneous heating of superficial tissue disease using a 915 MHz DCC (dual concentric conductor) array and High Dose Rate (HDR) brachytherapy delivered via an integrated conformal catheter array. The progress includes engineering design changes in the waterbolus, DCC configurations and fabrication techniques of the conformal multilayer applicator. The dosimetric impact of the thin copper DCC array is also assessed. Steady state fluid dynamics of the new waterbolus bag indicates nearly uniform flow with less than 1°C variation across a large (19×32cm) bolus. Thermometry data of the torso phantom acquired with computer controlled movement of fiberoptic temperature probes inside thermal mapping catheters indicate feasibility of real time feedback control for the DCC array. MR (magnetic resonance) scans of a torso phantom indicate that the waterbolus thickness across the treatment area is controlled by the pressure applied by the surrounding inflatable airbladder and applicator securing straps. The attenuation coefficient of the DCC array was measured as 3± 0.001% and 2.95±0.03 % using an ion chamber and OneDose™ dosimeters respectively. The performance of the combination applicator on patient phantoms provides valuable feedback to optimize the applicator prior use in the patient clinic.


  • Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators

    by Kavitha Arunachalam, Paolo F. Maccarini, Jaime L. Schlorff, Yngve Birkelund, Svein Jacobsen, Paul R. Stauffer

    A water bolus used in superficial hyperthermia couples the electromagnetic (EM) or acoustic energy into the target tissue and cools the tissue surface to minimise thermal hotspots and patient discomfort during treatment. Parametric analyses of the fluid pressure inside the bolus computed using 3D fluid dynamics simulations are used in this study to determine a bolus design with improved flow and surface temperature distributions for large area superficial heat applicators. The simulation results are used in the design and fabrication of a 19 × 32 cm prototype bolus with dual input-dual output (DIDO) flow channels. Sequential thermal images of the bolus surface temperature recorded for a step change in the circulating water temperature are used to assess steady state flow and surface temperature distributions across the bolus. Modelling and measurement data indicate substantial improvement in bolus flow and surface temperature distributions when changing from the previous single input–single output (SISO) to DIDO configuration. Temperature variation across the bolus at steady state was measured to be less than 0.8°C for the DIDO bolus compared to 1.5°C for the SISO water bolus. The new DIDO bolus configuration maintains a nearly uniform flow distribution and low variation in surface temperature over a large area typically treated in superficial hyperthermia.


  • Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test load

    by K Arunachalam, P R Stauffer, P F Maccarini, S Jacobsen, F Sterzer

    Microwave radiometry has been proposed as a viable noninvasive thermometry approach for monitoring subsurface tissue temperatures and potentially controlling power levels of multielement heat applicators during clinical hyperthermia treatments. With the evolution of technology, several analog microwave radiometry devices have been developed for biomedical applications. In this paper, we describe a digital microwave radiometer with built-in electronics for signal processing and automatic self-calibration. The performance of the radiometer with an Archimedean spiral receive antenna is evaluated over a bandwidth of 3.7-4.2 GHz in homogeneous and layered water test loads. Controlled laboratory experiments over the range of 30-50 degrees C characterize measurement accuracy, stability, repeatability and penetration depth sensitivity. The ability to sense load temperature through an intervening water coupling bolus of 6 mm thickness is also investigated. To assess the clinical utility and sensitivity to electromagnetic interference (EMI), experiments are conducted inside standard clinical hyperthermia treatment rooms with no EM shielding. The digital radiometer provided repeatable measurements with 0.075 degrees C resolution and standard deviation of 0.217 degrees C for homogeneous and layered tissue loads at temperatures between 32-45 degrees C. Within the 3.7-4.2 GHz band, EM noise rejection was good other than some interference from overhead fluorescent lights in the same room as the radiometer. The system response obtained for ideal water loads suggests that this digital radiometer should be useful for estimating subcutaneous tissue temperatures under a 6 mm waterbolus used during clinical hyperthermia treatments. The accuracy and stability data obtained in water test loads of several configurations support our expectation that single band radiometry should be sufficient for sub-surface temperature monitoring and power control of large multielement array superficial hyperthermia applicators.


  • A Thermal Monitoring Sheet With Low Influence From Adjacent Waterbolus for Tissue Surface Thermometry During Clinical Hyperthermia

    by Kavitha Arunachalam, Paolo F. Maccarini, Paul R. Stauffer

    This paper presents a complete thermal analysis of a novel conformal surface thermometer design with directional sensitivity for real-time temperature monitoring during hyperthermia treatments of large superficial cancer. The thermal monitoring sheet (TMS) discussed in this paper consists of a 2-D array of fiberoptic sensors embedded between two layers of flexible, low-loss, and thermally conductive printed circuit board (PCB) film. Heat transfer across all interfaces from the tissue surface through multiple layers of insulating dielectrics surrounding the small buried temperature sensor and into an adjacent temperature-regulated water coupling bolus was studied using 3-D thermal simulation software. Theoretical analyses were carried out to identify the most effective differential TMS probe configuration possible with commercially available flexible PCB materials and to compare their thermal responses with omnidirectional probes commonly used in clinical hyperthermia. A TMS sensor design that employs 0.0508-mm Kapton MTB and 0.2032-mm Kapton HN flexible polyimide films is proposed for tissue surface thermometry with low influence from the adjacent waterbolus. Comparison of the thermal simulations with clinical probes indicates the new differential TMS probe design to outperform in terms of both transient response and steady-state accuracy in selectively reading the tissue surface temperature, while decreasing the overall thermal barrier of the probe between the coupling waterbolus and tissue surface.


  • A Computational Investigation of Microwave Breast Imaging Using Deformable Reflector

    by Kavitha Arunachalam, Lalita Udpa, Satish S. Udpa

    In recent years, active microwave breast imaging is increasingly being viewed as a promising complementary imaging modality for cancer detection. In this paper, we present a novel deformable reflector microwave tomography technique for noninvasive characterization of the breast tissue. In contrast to conventional multitransceiver designs, the proposed technique utilizes a continuously deformable reflector with metallic coating to acquire field measurements for imaging. Computational feasibility of the proposed technique to image heterogeneous dielectric tissue property is evaluated using simplified 2-D breast models. The robustness of the deformable reflector-based tomography technique in imaging the spatial distribution of the tissue dielectric property in the presence of measurement noise is investigated using first-order Tikhonov regularization. Preliminary results obtained for the 2-D breast models appear promising and indicate further investigation of the new microwave tomography technique for breast imaging.


  • Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatments

    by K. Arunachalam, P. Maccarini, T. Juang, C. Gaeta, P. R. Stauffer

    This paper presents a novel conformal thermal monitoring sheet (TMS) sensor array with differential thermal sensitivity for measuring temperature distributions over large surface areas. Performance of the sensor array is evaluated in terms of thermal accuracy, mechanical stability and conformity to contoured surfaces, probe self-heating under irradiation from microwave and ultrasound hyperthermia sources, and electromagnetic field perturbation. A prototype with 4 x 4 array of fiber-optic sensors embedded between two flexible and thermally conducting polyimide films was developed as an alternative to the standard 1-2 mm diameter plastic catheter-based probes used in clinical hyperthermia. Computed tomography images and bending tests were performed to evaluate the conformability and mechanical stability respectively. Irradiation and thermal barrier tests were conducted and thermal response of the prototype was compared with round cross-sectional clinical probes. Bending and conformity tests demonstrated higher flexibility, dimensional stability and close conformity to human torso. Minimal perturbation of microwave fields and low probe self-heating was observed when irradiated with 915 MHz microwave and 3.4 MHz ultrasound sources. The transient and steady state thermal responses of the TMS array were superior compared to the clinical probes. A conformal TMS sensor array with improved thermal sensitivity and dimensional stability was investigated for real-time skin temperature monitoring. This fixed-geometry, body-conforming array of thermal sensors allows fast and accurate characterization of two-dimensional temperature distributions over large surface areas. The prototype TMS demonstrates significant advantages over clinical probes for characterizing skin temperature distributions during hyperthermia treatments of superficial tissue disease.