Polavarapu Venkata Ravi Chandra
Research Subjects
Polavarapu Venkata Ravi Chandra has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
D Ramkiran
1 shared publicationDandolu Ram Kiran
Department of Kamineni Institute of Dental Sciences, Narketpally, Andhra Pradesh, India
1 shared publicationGolla Vinay Kumar
Department of Kamineni Institute of Dental Sciences, Narketpally, Andhra Pradesh, India
1 shared publicationM Veerabhadra Gouda
1 shared publicationMjn Krishna
1 shared publicationMuppala Nagendra Krishna
Department of Kamineni Institute of Dental Sciences, Narketpally, Andhra Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2015
- Published by Medknow in Dental Research Journal
- Vol. 12 (4) , 331-6
Biofilm forming capacity of Enterococcus faecalis on Gutta-percha points treated with four disinfectants using confocal scanning laser microscope: An in vitro study
Background: The aim of this study was to evaluate and compare the in vitro biofilm forming capacity of Enterococcus faecalis on Gutta-percha points disinfected with four disinfectants. Materials and Methods: A total of 50 Gutta-percha points used in this study were divided into four test groups based on disinfectant (5.25% sodium hypochlorite, 2% chlorhexidine gluconate, 20% neem, 13% benzalkonium chloride [BAK]), and one control group. The Gutta-percha points were initially treated with corresponding disinfectants followed by anaerobic incubation in Brain Heart Infusion broth suspended with human serum and E. faecalis strain for 14 days. After incubation, these Gutta-percha points were stained with Acridine Orange (Sigma - Aldrich Co., St. Louis, MO, USA) and 0.5 mm thick cross section samples were prepared. The biofilm thickness of E. faecalis was analyzed quantitatively using a confocal scanning laser microscope. Results statistically analyzed using analysis of variance. P < 0.05 was considered to be significant. Results: Confocal scanning laser microscope showed reduced amount of E. faecalis biofilm on Gutta-percha points treated with BAK and sodium hypochlorite. Post-hoc (least square differences) test revealed that there is no statistically significant difference between BAK and sodium hypochlorite groups (P > 0.05). Conclusion: This study illustrates that the Gutta-percha points disinfected with sodium hypochlorite and BAK showed minimal biofilm growth on its surface.
- 1 January 2015
- Published by Medknow in Dental Research Journal
- Vol. 12 (4) , 331-6
Open AccessBiofilm forming capacity of Enterococcus faecalis on Gutta-percha points treated with four disinfectants using confocal scanning laser microscope: An in vitro study
Background: The aim of this study was to evaluate and compare the in vitro biofilm forming capacity of Enterococcus faecalis on Gutta-percha points disinfected with four disinfectants. Materials and Methods: A total of 50 Gutta-percha points used in this study were divided into four test groups based on disinfectant (5.25% sodium hypochlorite, 2% chlorhexidine gluconate, 20% neem, 13% benzalkonium chloride [BAK]), and one control group. The Gutta-percha points were initially treated with corresponding disinfectants followed by anaerobic incubation in Brain Heart Infusion broth suspended with human serum and E. faecalis strain for 14 days. After incubation, these Gutta-percha points were stained with Acridine Orange (Sigma - Aldrich Co., St. Louis, MO, USA) and 0.5 mm thick cross section samples were prepared. The biofilm thickness of E. faecalis was analyzed quantitatively using a confocal scanning laser microscope. Results statistically analyzed using analysis of variance. P < 0.05 was considered to be significant. Results: Confocal scanning laser microscope showed reduced amount of E. faecalis biofilm on Gutta-percha points treated with BAK and sodium hypochlorite. Post-hoc (least square differences) test revealed that there is no statistically significant difference between BAK and sodium hypochlorite groups (P > 0.05). Conclusion: This study illustrates that the Gutta-percha points disinfected with sodium hypochlorite and BAK showed minimal biofilm growth on its surface.
- Open Access
- 1 January 2014
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 8 (3) , 243-5
Comparative Evaluation of Marginal Adaptation of BiodentineTM and Other Commonly Used Root End Filling Materials-An Invitro Study
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.
- 1 January 2014
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 8 (3) , 243-5
Open AccessComparative Evaluation of Marginal Adaptation of BiodentineTM and Other Commonly Used Root End Filling Materials-An Invitro Study
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.
- 1 February 2013
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 14 (1) , 51-55
Microleakage of Class V Resin Composites using Various Self-etching Adhesives: An in vitro Study
Background and aims: Microleakage has been identified as a significant problem with composite restorations because of interfacial gap formation which can result in tooth discoloration, recurrent caries, possible pulpal involvement and restoration replacement. Aim of this study is to evaluate the microleakage of self-etch adhesive system at the coronal and apical margins of class V resin composite restorations under stereomicroscope at 20× magnification. Materials and methods: Class V cavities were prepared on the facial surfaces of 48 human premolars with coronal margins located in enamel and apical margins located in dentin. Teeth were divided into four groups: Group one—Xeno V; group two— G-Bond; group three—Clearfil S3 Bond; group four—control. After application of bonding agent and restoration, the teeth were subjected to thermocycling. The teeth were then immersed in 1% aqueous solution of methylene blue dye for 24 hours and sectioned to allow the assessment of microleakage under microscope. Results: Coronal and apical margins were scored separately using a 0-3 ordinal ranking system and the recorded values were statistically analyzed using Kruskal-Wallis, Mann- Whitney U-test and Wilcoxon signed rank test. Statistical analysis showed that there was less microleakage in Xeno V at coronal region and Clearfil S3 Bond in apical region, overall Clearfil S3 Bond showed less marginal permeability in both coronal and apical regions. Conclusion: Specimens restored with the Xeno V and Clearfil S3 Bond adhesive systems revealed reduced leakage at the coronal margin. At the apical margin, Xeno V showed greater leakage than the other groups, except the control. Clinical significance: In class V restorations restored with composite resin, the choice of material affects the microleakage and retention of the restoration. This study theorizes that the self-etch adhesives show less microleakage in the coronal area than the apical margin. How to cite this article: Chandra PVR, Harikumar V, Ramkiran D, Krishna MJN, Gouda MV. Microleakage of Class V Resin Composites using Various Self-etching Adhesives: An in vitro Study. J Contemp Dent Pract 2013;14(1):51-55.
- 1 February 2013
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 14 (1) , 51-55
Microleakage of Class V Resin Composites using Various Self-etching Adhesives: An in vitro Study
Background and aims: Microleakage has been identified as a significant problem with composite restorations because of interfacial gap formation which can result in tooth discoloration, recurrent caries, possible pulpal involvement and restoration replacement. Aim of this study is to evaluate the microleakage of self-etch adhesive system at the coronal and apical margins of class V resin composite restorations under stereomicroscope at 20× magnification. Materials and methods: Class V cavities were prepared on the facial surfaces of 48 human premolars with coronal margins located in enamel and apical margins located in dentin. Teeth were divided into four groups: Group one—Xeno V; group two— G-Bond; group three—Clearfil S3 Bond; group four—control. After application of bonding agent and restoration, the teeth were subjected to thermocycling. The teeth were then immersed in 1% aqueous solution of methylene blue dye for 24 hours and sectioned to allow the assessment of microleakage under microscope. Results: Coronal and apical margins were scored separately using a 0-3 ordinal ranking system and the recorded values were statistically analyzed using Kruskal-Wallis, Mann- Whitney U-test and Wilcoxon signed rank test. Statistical analysis showed that there was less microleakage in Xeno V at coronal region and Clearfil S3 Bond in apical region, overall Clearfil S3 Bond showed less marginal permeability in both coronal and apical regions. Conclusion: Specimens restored with the Xeno V and Clearfil S3 Bond adhesive systems revealed reduced leakage at the coronal margin. At the apical margin, Xeno V showed greater leakage than the other groups, except the control. Clinical significance: In class V restorations restored with composite resin, the choice of material affects the microleakage and retention of the restoration. This study theorizes that the self-etch adhesives show less microleakage in the coronal area than the apical margin. How to cite this article: Chandra PVR, Harikumar V, Ramkiran D, Krishna MJN, Gouda MV. Microleakage of Class V Resin Composites using Various Self-etching Adhesives: An in vitro Study. J Contemp Dent Pract 2013;14(1):51-55.