Lea Christierson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lea Christierson has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Johan Revstedt
Department of Energy Sciences, Lund University, Lund, Sweden
5 shared publications - Hanna Isaksson
Department of Biomedical Engineering Lund University Lund Sweden
4 shared publications - Petter Frieberg
Lund University
4 shared publications - Johannes Töger
Clinical Physiology, Department of Clinical Sciences Lund Lund University Lund Sweden
3 shared publications Nina Hakacova
3 shared publications- Petru Liuba
Pediatric Cardiology, Children’s Heart Centre, Skåne University Hospital, 221 85 Lund, Sweden
3 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 218
Mitral valve strain and chordal forces as potential diagnostic parameters in pediatric mitral valve disease
- 11 November 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 218
Open AccessMitral valve strain and chordal forces as potential diagnostic parameters in pediatric mitral valve disease
- Open Access
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Toward precision in simulation of paediatric mitral valve repair using patient-specific fluid–structure interaction modelling
Aims: Assessment of mitral valve (MV) function and haemodynamics is essential for optimizing surgical repair in children with mitral regurgitation. Patient-specific fluid–structure interaction (FSI) modelling can capture the complex interplay between valvular mechanics and blood flow. In this study, we apply a patient-specific FSI framework to evaluate MV function and haemodynamics in paediatric patients before and after surgery. Methods and results: Seven paediatric patients with mitral regurgitation were analysed (age range: 2–17 years; median: 6 years; 57% female). Patient-specific MV apparatus geometries were segmented from pre- and postoperative 3D echocardiograms. Flow boundary conditions were derived from left ventricular volume measurements. Valve dynamics and haemodynamics were simulated using the FSI framework. Model performance was evaluated against echocardiographic data, pre- and postoperatively. The FSI model reproduced the angle of the regurgitant jet. Preoperatively, the regurgitation grade matched echocardiographic assessment in six of seven patients, and postoperatively in four of seven. The site of regurgitation was correctly identified in six of seven patients, pre- and postoperatively. The model reproduced the observed intraventricular flow patterns in most patients, and the simulated transvalvular pressure gradients agreed with Doppler measurements (mean difference: 0.38 ± 1.57 mmHg preoperatively, –0.42 ± 3.26 mmHg postoperatively). Conclusion: The proposed FSI framework captured MV function, haemodynamics, and disease-specific features in paediatric patients pre- and postoperatively, based on evaluation in one of the largest cohorts for the field. This computational framework has the potential to enable predictive simulations that could support surgical planning in the future and improve repair outcomes in children.
- 1 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Open AccessToward precision in simulation of paediatric mitral valve repair using patient-specific fluid–structure interaction modelling
Aims: Assessment of mitral valve (MV) function and haemodynamics is essential for optimizing surgical repair in children with mitral regurgitation. Patient-specific fluid–structure interaction (FSI) modelling can capture the complex interplay between valvular mechanics and blood flow. In this study, we apply a patient-specific FSI framework to evaluate MV function and haemodynamics in paediatric patients before and after surgery. Methods and results: Seven paediatric patients with mitral regurgitation were analysed (age range: 2–17 years; median: 6 years; 57% female). Patient-specific MV apparatus geometries were segmented from pre- and postoperative 3D echocardiograms. Flow boundary conditions were derived from left ventricular volume measurements. Valve dynamics and haemodynamics were simulated using the FSI framework. Model performance was evaluated against echocardiographic data, pre- and postoperatively. The FSI model reproduced the angle of the regurgitant jet. Preoperatively, the regurgitation grade matched echocardiographic assessment in six of seven patients, and postoperatively in four of seven. The site of regurgitation was correctly identified in six of seven patients, pre- and postoperatively. The model reproduced the observed intraventricular flow patterns in most patients, and the simulated transvalvular pressure gradients agreed with Doppler measurements (mean difference: 0.38 ± 1.57 mmHg preoperatively, –0.42 ± 3.26 mmHg postoperatively). Conclusion: The proposed FSI framework captured MV function, haemodynamics, and disease-specific features in paediatric patients pre- and postoperatively, based on evaluation in one of the largest cohorts for the field. This computational framework has the potential to enable predictive simulations that could support surgical planning in the future and improve repair outcomes in children.
- Open Access
- 2 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110455
Prediction of healthy mitral valve hemodynamics in children and adults: validation of fluid-structure interaction simulations against echocardiography and magnetic resonance imaging
- 2 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110455
Open AccessPrediction of healthy mitral valve hemodynamics in children and adults: validation of fluid-structure interaction simulations against echocardiography and magnetic resonance imaging
- Open Access
- 23 May 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (5) , 572-583
Multi-Modal in Vitro Experiments Mimicking the Flow Through a Mitral Heart Valve Phantom
Purpose: Fluid-structure interaction (FSI) models are more commonly applied in medical research as computational power is increasing. However, understanding the accuracy of FSI models is crucial, especially in the context of heart valve disease in patient-specific models. Therefore, this study aimed to create a multi-modal benchmarking data set for cardiac-inspired FSI models, based on clinically important parameters, such as the pressure, velocity, and valve opening, with an in vitro phantom setup. Method: An in vitro setup was developed with a 3D-printed phantom mimicking the left heart, including a deforming mitral valve. A range of pulsatile flows were created with a computer-controlled motor-and-pump setup. Catheter pressure measurements, magnetic resonance imaging (MRI), and echocardiography (Echo) imaging were used to measure pressure and velocity in the domain. Furthermore, the valve opening was quantified based on cine MRI and Echo images. Result: The experimental setup, with 0.5% cycle-to-cycle variation, was successfully built and six different flow cases were investigated. Higher velocity through the mitral valve was observed for increased cardiac output. The pressure difference across the valve also followed this trend. The flow in the phantom was qualitatively assessed by the velocity profile in the ventricle and by streamlines obtained from 4D phase-contrast MRI. Conclusion: A multi-modal set of data for validation of FSI models has been created, based on parameters relevant for diagnosis of heart valve disease. All data is publicly available for future development of computational heart valve models.
- 23 May 2024
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (5) , 572-583
Open AccessMulti-Modal in Vitro Experiments Mimicking the Flow Through a Mitral Heart Valve Phantom
Purpose: Fluid-structure interaction (FSI) models are more commonly applied in medical research as computational power is increasing. However, understanding the accuracy of FSI models is crucial, especially in the context of heart valve disease in patient-specific models. Therefore, this study aimed to create a multi-modal benchmarking data set for cardiac-inspired FSI models, based on clinically important parameters, such as the pressure, velocity, and valve opening, with an in vitro phantom setup. Method: An in vitro setup was developed with a 3D-printed phantom mimicking the left heart, including a deforming mitral valve. A range of pulsatile flows were created with a computer-controlled motor-and-pump setup. Catheter pressure measurements, magnetic resonance imaging (MRI), and echocardiography (Echo) imaging were used to measure pressure and velocity in the domain. Furthermore, the valve opening was quantified based on cine MRI and Echo images. Result: The experimental setup, with 0.5% cycle-to-cycle variation, was successfully built and six different flow cases were investigated. Higher velocity through the mitral valve was observed for increased cardiac output. The pressure difference across the valve also followed this trend. The flow in the phantom was qualitatively assessed by the velocity profile in the ventricle and by streamlines obtained from 4D phase-contrast MRI. Conclusion: A multi-modal set of data for validation of FSI models has been created, based on parameters relevant for diagnosis of heart valve disease. All data is publicly available for future development of computational heart valve models.
- Open Access
Multi-modal Phantom Experiments, mimicking Flow through the Mitral Heart Valve
Purpose: Fluid-structure interaction (FSI) models are more commonly applied in medical research as computational power is increasing. However, understanding the accuracy of FSI models is crucial, especially in the context of heart valve disease in patient-specific models. Therefore, this study aimed to create a multi-modal benchmarking data set for FSI models, based on clinically important parameters, such as the pressure, velocity, and valve opening, with an in vitro phantom setup. Method: An in vitro setup was developed with a 3D-printed phantom mimicking the left heart, including a deforming mitral valve. A range of pulsatile flows was created with a computer-controlled motor-and-pump setup. Invasive catheter measurements, magnetic resonance imaging (MRI), and echocardiography (Echo) imaging were used to measure pressure and velocity in the domain. Furthermore, the valve opening was quantified based on cine MRI and Echo images. Result: The experimental setup, with 0.5 % cycle-to-cycle variation, was successfully built and six different flow cases were investigated. Higher velocity through the mitral valve was observed for increased cardiac output. The pressure difference across the valve also followed this trend. The flow in the phantom was qualitatively assessed by the velocity profile in the ventricle and by streamlines obtained from 4D phase-contrast MRI. Conclusion: A multi-modal set of validation data for FSI models has been created, based on parameters relevant for diagnosis of heart valve disease. All data is publicly available for future development of computational heart valve models.
Open AccessMulti-modal Phantom Experiments, mimicking Flow through the Mitral Heart Valve
Purpose: Fluid-structure interaction (FSI) models are more commonly applied in medical research as computational power is increasing. However, understanding the accuracy of FSI models is crucial, especially in the context of heart valve disease in patient-specific models. Therefore, this study aimed to create a multi-modal benchmarking data set for FSI models, based on clinically important parameters, such as the pressure, velocity, and valve opening, with an in vitro phantom setup. Method: An in vitro setup was developed with a 3D-printed phantom mimicking the left heart, including a deforming mitral valve. A range of pulsatile flows was created with a computer-controlled motor-and-pump setup. Invasive catheter measurements, magnetic resonance imaging (MRI), and echocardiography (Echo) imaging were used to measure pressure and velocity in the domain. Furthermore, the valve opening was quantified based on cine MRI and Echo images. Result: The experimental setup, with 0.5 % cycle-to-cycle variation, was successfully built and six different flow cases were investigated. Higher velocity through the mitral valve was observed for increased cardiac output. The pressure difference across the valve also followed this trend. The flow in the phantom was qualitatively assessed by the velocity profile in the ventricle and by streamlines obtained from 4D phase-contrast MRI. Conclusion: A multi-modal set of validation data for FSI models has been created, based on parameters relevant for diagnosis of heart valve disease. All data is publicly available for future development of computational heart valve models.
- Open Access
- 2 February 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 171, 108033
Validation of fluid-structure interaction simulations of the opening phase of phantom mitral heart valves under physiologically inspired conditions
- 2 February 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 171, 108033
Open AccessValidation of fluid-structure interaction simulations of the opening phase of phantom mitral heart valves under physiologically inspired conditions