Juan Camilo Martínez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juan Camilo Martínez has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Felipe Patiño-Lugo
Universidad de Antioquía
2 shared publications - Ivan Dario Florez
Department of Pediatrics, University of Antioquia, Medellin, Colombia
2 shared publications - Mary Lopez-Perez
Centre for translational Medicine and Parasitology, Department of Immunology and Microbiology, Faculty of Health and Medical Sciences, University of Copenhagen , Copenhagen
2 shared publications - Viviana Vélez-Marín
Unit of Evidence and Deliberation for Decision Making UNED, Medical Research Institute, School of Medicine, University of Antioquia, Medellin, Colombia
2 shared publications
Latest Publications
- Open Access
- 2 November 2024
- Published by Springer Nature in Malaria Journal
- Vol. 23 (1) , 1-11
Diagnostic accuracy of the point-of-care standard G6PD test™ (SD Biosensor) for glucose-6-phosphate dehydrogenase deficiency: a systematic review and meta-analysis
Background: Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic enzymopathy that can induce haemolysis triggered by various factors, including some anti-malarial drugs. Although many Point-of-Care (PoC) tests, such as Standard G6PD™ are available to detect G6PDd, its pooled diagnostic test accuracy (DTA) remains unknown. Methods: To estimate the DTA of StandG6PD-BS at various thresholds of G6PDd, a systematic review with a DTA meta-analysis were conducted, searching EMBASE, MEDLINE, and SciELO databases up to April 4, 2024.The included studies were those that measured G6PD activity using StandG6PD-BS (reference test) and spectrophotometry (gold standard) in patients suspected of having G6PDd. The risk of bias (RoB) of the studies was assessed using the QUADAS-2 tool and the certainty of evidence (CoE) with the GRADE approach. For the estimation of within-study DTA, a random-effect bivariate meta-analysis was performed to determine the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds, and a graphical analysis of the heterogeneity using crosshair and Confidence Regions on receiver operating characteristic (ROC) space plots. Results: After screening 2496 reports, four studies were included with 7864 participants covering all thresholds. Two studies had high RoB in QUADAS-2 domains 2 and 3, and the others had low RoB, with low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds, respectively. The pooled sensitivity was 99.1%, 95.7%, and 90% for 30%, 70%, and 80% thresholds, respectively. The pooled specificity was 97.4%; 92.9%; and 89.0% for 30%, 70%, and 80% thresholds, respectively. Conclusion: StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.
- 2 November 2024
- Published by Springer Nature in Malaria Journal
- Vol. 23 (1) , 1-11
Open AccessDiagnostic accuracy of the point-of-care standard G6PD test™ (SD Biosensor) for glucose-6-phosphate dehydrogenase deficiency: a systematic review and meta-analysis
Background: Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic enzymopathy that can induce haemolysis triggered by various factors, including some anti-malarial drugs. Although many Point-of-Care (PoC) tests, such as Standard G6PD™ are available to detect G6PDd, its pooled diagnostic test accuracy (DTA) remains unknown. Methods: To estimate the DTA of StandG6PD-BS at various thresholds of G6PDd, a systematic review with a DTA meta-analysis were conducted, searching EMBASE, MEDLINE, and SciELO databases up to April 4, 2024.The included studies were those that measured G6PD activity using StandG6PD-BS (reference test) and spectrophotometry (gold standard) in patients suspected of having G6PDd. The risk of bias (RoB) of the studies was assessed using the QUADAS-2 tool and the certainty of evidence (CoE) with the GRADE approach. For the estimation of within-study DTA, a random-effect bivariate meta-analysis was performed to determine the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds, and a graphical analysis of the heterogeneity using crosshair and Confidence Regions on receiver operating characteristic (ROC) space plots. Results: After screening 2496 reports, four studies were included with 7864 participants covering all thresholds. Two studies had high RoB in QUADAS-2 domains 2 and 3, and the others had low RoB, with low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds, respectively. The pooled sensitivity was 99.1%, 95.7%, and 90% for 30%, 70%, and 80% thresholds, respectively. The pooled specificity was 97.4%; 92.9%; and 89.0% for 30%, 70%, and 80% thresholds, respectively. Conclusion: StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.
- Open Access
Diagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature
Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic enzymopathy that can induce hemolysis triggered by various factors, including some anti-malarial drugs. Although many Point-of-Care (PoC) tests, such as STANDARD G6PD TM manufactured by SD biosensor (StandG6PD-BS), are available to detect G6PDd, its pooled diagnostic test accuracy (DTA) remains unknown. To estimate the DTA of StandG6PD-BS at various thresholds of G6PDd, we conducted a systematic review with a DTA meta-analysis, searching EMBASE, MEDLINE, and SciELO databases up to June 30, 2023. We included studies measuring G6PD activity using StandG6PD-BS (reference test) and spectrophotometry (gold standard) in patients suspected of having G6PDd. We assessed the risk of bias (RoB) of the studies using the QUADAS-2 tool and the certainty of evidence (CoE) with the GRADE approach. Our approach included the estimation of within-study DTA, a random-effect bivariate meta-analysis to determine the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds, and a graphical analysis of the heterogeneity using crosshair and Confidence Regions on receiver operating characteristic (ROC) space plots. After screening 2,407 reports, we included four studies with 7,864 participants covering all thresholds. Two studies had high RoB in QUADAS-2 domains 2 and 3, and the others had low RoB. We also found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds, respectively. The pooled sensitivity was 99.1% (95%CI 96.9-99.7%, CoE: high), 95.7% (92.0-97.0%, high), and 90% (78.0-96.5%, low) for 30%, 70%, and 80% thresholds, respectively. The pooled specificity was 97.4% (95%CI 95.0; 98.4%, high); 92.9% (85.0-96.4%, high); and 89.0% (76.0-96.0%, moderate) for 30%, 70%, and 80% thresholds, respectively. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds. Author summary: Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic disease that can induce the destruction of red blood cells leading to anemia triggered by various factors, including some drugs used for malaria treatment. After a literature search in different databases up to January 31, 2023, we pooled diagnostic test accuracy of the Point-of-Care (PoC) STANDARD G6PDTM test manufactured by SD biosensor (StandG6PD-BS) used to identify the G6PDd. Although two of the four studies included showed a high Risk of Bias related to the index test and the reference standard domains of the QUADAS-2 tool, the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds were around 90%, with better sensitivity and specificity values for the 30% threshold (99.1% and 97.4%) compared with 70% (95.7% and 92.9%) and 80% (90% and 89%) threshold. We found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.
Open AccessDiagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature
Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic enzymopathy that can induce hemolysis triggered by various factors, including some anti-malarial drugs. Although many Point-of-Care (PoC) tests, such as STANDARD G6PD TM manufactured by SD biosensor (StandG6PD-BS), are available to detect G6PDd, its pooled diagnostic test accuracy (DTA) remains unknown. To estimate the DTA of StandG6PD-BS at various thresholds of G6PDd, we conducted a systematic review with a DTA meta-analysis, searching EMBASE, MEDLINE, and SciELO databases up to June 30, 2023. We included studies measuring G6PD activity using StandG6PD-BS (reference test) and spectrophotometry (gold standard) in patients suspected of having G6PDd. We assessed the risk of bias (RoB) of the studies using the QUADAS-2 tool and the certainty of evidence (CoE) with the GRADE approach. Our approach included the estimation of within-study DTA, a random-effect bivariate meta-analysis to determine the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds, and a graphical analysis of the heterogeneity using crosshair and Confidence Regions on receiver operating characteristic (ROC) space plots. After screening 2,407 reports, we included four studies with 7,864 participants covering all thresholds. Two studies had high RoB in QUADAS-2 domains 2 and 3, and the others had low RoB. We also found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds, respectively. The pooled sensitivity was 99.1% (95%CI 96.9-99.7%, CoE: high), 95.7% (92.0-97.0%, high), and 90% (78.0-96.5%, low) for 30%, 70%, and 80% thresholds, respectively. The pooled specificity was 97.4% (95%CI 95.0; 98.4%, high); 92.9% (85.0-96.4%, high); and 89.0% (76.0-96.0%, moderate) for 30%, 70%, and 80% thresholds, respectively. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds. Author summary: Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic disease that can induce the destruction of red blood cells leading to anemia triggered by various factors, including some drugs used for malaria treatment. After a literature search in different databases up to January 31, 2023, we pooled diagnostic test accuracy of the Point-of-Care (PoC) STANDARD G6PDTM test manufactured by SD biosensor (StandG6PD-BS) used to identify the G6PDd. Although two of the four studies included showed a high Risk of Bias related to the index test and the reference standard domains of the QUADAS-2 tool, the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds were around 90%, with better sensitivity and specificity values for the 30% threshold (99.1% and 97.4%) compared with 70% (95.7% and 92.9%) and 80% (90% and 89%) threshold. We found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.