Milkias Berhanu Tuka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Milkias Berhanu Tuka has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Mohit Bajaj
Department of Electrical Engineering, Graphic Era (Deemed to be University), Dehradun, India
24 shared publications - Arvind Ramnarayan Singh
Department of Electrical Engineering, School of Physics and Electronic Engineering, Hanjiang Normal University, Shiyan, China
10 shared publications Mohit Bajaj
Hourani Center for Applied Scientific Research, Al-Ahliyya Amman University, Amman, Jordan
6 shared publicationsReagan Jean Jacques Molu
Technology and Applied Sciences Laboratory, U.I.T. of Douala, University of Douala, Douala, Cameroon
5 shared publications- Busireddy Hemanth Kumar
Department of Electrical and Electronics Engineering, Mohan Babu University (Erstwhile Sree Vidyanikethan Engineering College), Tirupati, India
4 shared publications - Endalew Ayenew
Electrical Power and Control Engineering, Adama Science and Technology University, Adama, Ethiopia
4 shared publications
Latest Publications
- 25 April 2026
- Published by SAGE Publications in Wind Engineering
Enhanced torque control of a grid-connected DFIG wind turbine system under variable wind speed conditions
This paper describes an appropriate hybrid control mechanism to enhance the turbine peak output torque of a DFIG-based grid-connected wind energy conversion system at variable wind speed conditions. These sudden variations pose a critical challenge to maximizing output torque and other associated optimal parameters. To address the identified research gaps, this study aimed to design a novel hybrid ANFIS-PI controller for a back-to-back converter, confirming superior efficiency and responsiveness. The recent MATLAB–Simulink model simulation results illustrate that an intended ANFIS-PI controller achieved a peak output torque of 13.31 kNm, compared with 13.25 kNm for the FLC-PI controller, both evaluated against a PI-controller benchmark of 12.09 kNm. To achieve these results by enhancing the maximum power coefficient to 0.55 by the ANFIS-PI, compared with 0.547 from the FLC-PI and 0.4801 for the PI controller, at an optimal blade angle of 0° and the maximum speed of 12.5 m/s.
- 25 April 2026
- Published by SAGE Publications in Wind Engineering
Enhanced torque control of a grid-connected DFIG wind turbine system under variable wind speed conditions
This paper describes an appropriate hybrid control mechanism to enhance the turbine peak output torque of a DFIG-based grid-connected wind energy conversion system at variable wind speed conditions. These sudden variations pose a critical challenge to maximizing output torque and other associated optimal parameters. To address the identified research gaps, this study aimed to design a novel hybrid ANFIS-PI controller for a back-to-back converter, confirming superior efficiency and responsiveness. The recent MATLAB–Simulink model simulation results illustrate that an intended ANFIS-PI controller achieved a peak output torque of 13.31 kNm, compared with 13.25 kNm for the FLC-PI controller, both evaluated against a PI-controller benchmark of 12.09 kNm. To achieve these results by enhancing the maximum power coefficient to 0.55 by the ANFIS-PI, compared with 0.547 from the FLC-PI and 0.4801 for the PI controller, at an optimal blade angle of 0° and the maximum speed of 12.5 m/s.
- Top Cited PapersOpen Access
- 19 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Enhancing MPPT performance of a grid-connected Doubly-Fed induction generator-based wind power plant using hybrid ANFIS-PI control strategy
This paper focuses on an effective control technique for enhancing the Maximum Power Point Tracking (MPPT) performance of a grid-connected DFIG-based wind power plant under continuously varying wind conditions. However, rapid fluctuations in wind speeds, uncertainties in parameters, and grid disturbances are key challenges to enhancing the MPPT performance capability. Considering these struggles, this study aims to model a modified dynamic DFIG-based wind turbine system and develop a hybrid Adaptive Neuro-Fuzzy Inference System (ANFIS) with a Proportional-Integral (PI) controller on the back-to-back converter at the rotor and grid sides. The actual limited ranges of wind speed and output power generation data of the Adama II wind power plant in Ethiopia are utilized as input and output variables for the ANFIS controller. The simulation results from the latest version of R2024a-MATLAB-Simulink software show that the proposed ANFIS-PI reached an MPPT of 2.22 MW compared to the FLC-PI controller attained 2.2 MW using the benchmark as the reference value of 1.561 MW in the PI controller, by improving the maximum power coefficient of 0.5504 compared to 0.5473 using the baseline as the reference value of 0.4109, respectively, at a rated wind speed of 12.5 m/s and an optimal pitch angle of 0°.
- 19 January 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Top Cited PapersOpen AccessEnhancing MPPT performance of a grid-connected Doubly-Fed induction generator-based wind power plant using hybrid ANFIS-PI control strategy
This paper focuses on an effective control technique for enhancing the Maximum Power Point Tracking (MPPT) performance of a grid-connected DFIG-based wind power plant under continuously varying wind conditions. However, rapid fluctuations in wind speeds, uncertainties in parameters, and grid disturbances are key challenges to enhancing the MPPT performance capability. Considering these struggles, this study aims to model a modified dynamic DFIG-based wind turbine system and develop a hybrid Adaptive Neuro-Fuzzy Inference System (ANFIS) with a Proportional-Integral (PI) controller on the back-to-back converter at the rotor and grid sides. The actual limited ranges of wind speed and output power generation data of the Adama II wind power plant in Ethiopia are utilized as input and output variables for the ANFIS controller. The simulation results from the latest version of R2024a-MATLAB-Simulink software show that the proposed ANFIS-PI reached an MPPT of 2.22 MW compared to the FLC-PI controller attained 2.2 MW using the benchmark as the reference value of 1.561 MW in the PI controller, by improving the maximum power coefficient of 0.5504 compared to 0.5473 using the baseline as the reference value of 0.4109, respectively, at a rated wind speed of 12.5 m/s and an optimal pitch angle of 0°.
- Open Access
- 17 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Experimental investigation of al₂o₃ nanoparticle-enhanced natural ester oil as a biodegradable liquid dielectric for transformers
Mineral oil has been widely used as a liquid dielectric in transformers, serving as both an insulating and heat dissipation medium. However, its poor biodegradability, low fire resistance, and environmental concerns limit its long-term viability. To address these challenges, this study investigates natural ester oil (NEO) as an eco-friendly, biodegradable alternative, offering enhanced insulation and thermal performance. The research focuses on evaluating NEO’s key characteristics, aging behavior, and failure probability, with and without Al₂O₃ nanoparticle enhancement. A 60-day accelerated thermal aging test at 100 °C was conducted to assess the degradation resistance of NEO compared to mineral oil. The effects of partial discharge, creepage failure, and electrical stress were analyzed, and a Weibull statistical model was applied to predict insulation failure probabilities. Experimental results confirm that NEO demonstrates superior breakdown strength, lower degradation rate, and higher fire safety. The addition of Al₂O₃ nanoparticles significantly improves dielectric properties, reduces viscosity, and enhances the thermal stability of NEO, making it more suitable for transformer applications. This research establishes nano-enhanced NEO as a superior alternative to mineral oil, offering higher insulation performance, improved thermal durability, and enhanced fire safety. The findings advocate for its adoption as a sustainable, high-performance dielectric for modern transformers, promoting both reliability and environmental compliance.
- 17 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Open AccessExperimental investigation of al₂o₃ nanoparticle-enhanced natural ester oil as a biodegradable liquid dielectric for transformers
Mineral oil has been widely used as a liquid dielectric in transformers, serving as both an insulating and heat dissipation medium. However, its poor biodegradability, low fire resistance, and environmental concerns limit its long-term viability. To address these challenges, this study investigates natural ester oil (NEO) as an eco-friendly, biodegradable alternative, offering enhanced insulation and thermal performance. The research focuses on evaluating NEO’s key characteristics, aging behavior, and failure probability, with and without Al₂O₃ nanoparticle enhancement. A 60-day accelerated thermal aging test at 100 °C was conducted to assess the degradation resistance of NEO compared to mineral oil. The effects of partial discharge, creepage failure, and electrical stress were analyzed, and a Weibull statistical model was applied to predict insulation failure probabilities. Experimental results confirm that NEO demonstrates superior breakdown strength, lower degradation rate, and higher fire safety. The addition of Al₂O₃ nanoparticles significantly improves dielectric properties, reduces viscosity, and enhances the thermal stability of NEO, making it more suitable for transformer applications. This research establishes nano-enhanced NEO as a superior alternative to mineral oil, offering higher insulation performance, improved thermal durability, and enhanced fire safety. The findings advocate for its adoption as a sustainable, high-performance dielectric for modern transformers, promoting both reliability and environmental compliance.
- Open Access
- 4 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-25
Enhanced CPCV algorithm for improving power quality in electric vehicle battery charging
There are several difficulties to overcome when integrating electric vehicles (EVs) into power distribution networks, especially when it comes to preserving power quality (PQ) because of the harmonic distortion produced throughout battery charging. These issues are not sufficiently addressed by conventional charging algorithms like Constant Current Constant Voltage (CCCV), which frequently leads to higher Total Harmonic Distortion (THD), decreased system efficiency, and generally insufficient performance PQ. The Constant Power Constant Voltage (CPCV) charging algorithm, which is a revolutionary approach to addressing these issues, dynamically modifies the charging power according to the battery’s state of charge (SoC). Compared to conventional techniques, this creative technology efficiently controls harmonic emissions and enhances power quality. Three distinct EV models—the Tesla Model 3, the BYD ATTO 3, and the Kia EV3 Long Range—were used in simulations to assess the algorithm’s performance. The findings show that the CPCV algorithm works noticeably better than the CCCV method with respect to of lowering harmonic distortion; for the 3rd, 5th, 7th harmonics, THD values were lowered to as low as 0.41%. Furthermore, comparing to the greater loss seen in CCCV (3.85 kWh to 5.89 kWh), the CPCV algorithm also demonstrated significant decreases in energy losses, ranging from 2.72 kWh to 3.51 kWh. Furthermore, the CPCV method boosted efficiency by guaranteeing a power factor that was almost constant throughout all charging conditions. These results demonstrate the CPCV algorithm’s efficacy in improving power quality, maximizing energy use, and facilitating the smooth integration of EVs into contemporary distribution systems. In order to meet the increasing demand for EV charging infrastructure and guarantee an additional dependable and sustainable power system, CPCV offers an attractive option by reducing harmonic distortion and increasing general charging efficiency.
- 4 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-25
Open AccessEnhanced CPCV algorithm for improving power quality in electric vehicle battery charging
There are several difficulties to overcome when integrating electric vehicles (EVs) into power distribution networks, especially when it comes to preserving power quality (PQ) because of the harmonic distortion produced throughout battery charging. These issues are not sufficiently addressed by conventional charging algorithms like Constant Current Constant Voltage (CCCV), which frequently leads to higher Total Harmonic Distortion (THD), decreased system efficiency, and generally insufficient performance PQ. The Constant Power Constant Voltage (CPCV) charging algorithm, which is a revolutionary approach to addressing these issues, dynamically modifies the charging power according to the battery’s state of charge (SoC). Compared to conventional techniques, this creative technology efficiently controls harmonic emissions and enhances power quality. Three distinct EV models—the Tesla Model 3, the BYD ATTO 3, and the Kia EV3 Long Range—were used in simulations to assess the algorithm’s performance. The findings show that the CPCV algorithm works noticeably better than the CCCV method with respect to of lowering harmonic distortion; for the 3rd, 5th, 7th harmonics, THD values were lowered to as low as 0.41%. Furthermore, comparing to the greater loss seen in CCCV (3.85 kWh to 5.89 kWh), the CPCV algorithm also demonstrated significant decreases in energy losses, ranging from 2.72 kWh to 3.51 kWh. Furthermore, the CPCV method boosted efficiency by guaranteeing a power factor that was almost constant throughout all charging conditions. These results demonstrate the CPCV algorithm’s efficacy in improving power quality, maximizing energy use, and facilitating the smooth integration of EVs into contemporary distribution systems. In order to meet the increasing demand for EV charging infrastructure and guarantee an additional dependable and sustainable power system, CPCV offers an attractive option by reducing harmonic distortion and increasing general charging efficiency.
- Open Access
- 29 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-28
Seismic wave reflection characteristics and wave-induced fluid flow in unsaturated porous solid
This study examines the characteristics of seismic wave reflection and wave-induced fluid flow (WIFF) in an unsaturated porous solid half-space confined beneath an impermeable plane surface. We first present the field equations and constitutive relations for partially saturated porous media. Next, we solve these equations in terms of the Christoffel equations, thereby addressing the propagation of a four-plane harmonic wave. These waves propagate as inhomogeneous waves at stress-free, impermeable boundary surfaces due to the medium’s dissipative properties. Furthermore, we compute the reflection coefficients from stress-free impervious boundary surfaces at arbitrary angles. The incidence of the \(P_1/SV\) wave generates four reflected waves. The calculation of theoretical formulations for reflection coefficients involves a set of four non-homogeneous linear equations derived from boundary conditions. Subsequently, these reflection coefficients are utilized to calculate the WIFF and the partitioning of incident energy at the impervious boundary of the porous solid. A numerical example is considered to investigate the effects of wave frequency, incidence direction, and elastic parameters such as porosity, inclusion radius, and liquid saturation on energy partitioning and wave-induced fluid flow. The conservation of incident energy has been confirmed at every angle of incidence. The numerical results demonstrate a significant dependence of energy shares of distinct reflected waves on the incident direction, saturation, porosity, inclusion radius, wave frequency, and WIFF. This theoretical study serves as a valuable tool for subsurface reservoir characterization, with applications in hydrocarbon exploration, \(CO_2\) sequestration monitoring, and other geological engineering fields.- 29 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-28
Open AccessSeismic wave reflection characteristics and wave-induced fluid flow in unsaturated porous solid
This study examines the characteristics of seismic wave reflection and wave-induced fluid flow (WIFF) in an unsaturated porous solid half-space confined beneath an impermeable plane surface. We first present the field equations and constitutive relations for partially saturated porous media. Next, we solve these equations in terms of the Christoffel equations, thereby addressing the propagation of a four-plane harmonic wave. These waves propagate as inhomogeneous waves at stress-free, impermeable boundary surfaces due to the medium’s dissipative properties. Furthermore, we compute the reflection coefficients from stress-free impervious boundary surfaces at arbitrary angles. The incidence of the \(P_1/SV\) wave generates four reflected waves. The calculation of theoretical formulations for reflection coefficients involves a set of four non-homogeneous linear equations derived from boundary conditions. Subsequently, these reflection coefficients are utilized to calculate the WIFF and the partitioning of incident energy at the impervious boundary of the porous solid. A numerical example is considered to investigate the effects of wave frequency, incidence direction, and elastic parameters such as porosity, inclusion radius, and liquid saturation on energy partitioning and wave-induced fluid flow. The conservation of incident energy has been confirmed at every angle of incidence. The numerical results demonstrate a significant dependence of energy shares of distinct reflected waves on the incident direction, saturation, porosity, inclusion radius, wave frequency, and WIFF. This theoretical study serves as a valuable tool for subsurface reservoir characterization, with applications in hydrocarbon exploration, \(CO_2\) sequestration monitoring, and other geological engineering fields. - Open Access
- 25 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-22
Comprehensive techno-economic optimization and performance analysis of molten salt concentrated solar power tower plants in Algeria
This paper presents a comprehensive techno-economic analysis of three molten salt Concentrated Solar Power (CSP) tower plants located in the regions of Mechria, Adrar, and Tindouf in Algeria. The study evaluates the thermal efficiency, economic feasibility, and performance of these CSP using the System Advisor Model (SAM) software, which accurately models Direct Normal Irradiance (DNI), a critical factor influencing plant performance. Key parameters analyzed include Solar Multiple (SM), Thermal energy storage (TES) hours, capacity factor (CF), and the Levelized Cost of Energy (LCOE). The results demonstrate that an optimal heliostat field configuration with a SM of 1.8 and 10 h of TES achieves a capacity factor of 51.49%, with a minimum LCOE of 0.097 $/kWh. In Mechria, with operational and maintenance costs projected at 2.51 million dollars. For the Adrar region, a SM of 1.6 and TES of 2 h yield an LCOE of 0.18 $/kWh at a capacity factor of 24.03%. Similarly, in Tindouf, a SM of 1.6 and TES of 8 h result in a capacity factor of 18.95% and an LCOE of 0.17 $/kWh. The analysis reveals that the design of CSP systems, particularly the combination of solar Multiple and TES, plays a pivotal role in optimizing the economic performance of the plants, This approach enables researchers to save time and costs by using satellite-derived DNI estimations, enhancing data accuracy and optimizing CSP deployment.
- 25 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-22
Open AccessComprehensive techno-economic optimization and performance analysis of molten salt concentrated solar power tower plants in Algeria
This paper presents a comprehensive techno-economic analysis of three molten salt Concentrated Solar Power (CSP) tower plants located in the regions of Mechria, Adrar, and Tindouf in Algeria. The study evaluates the thermal efficiency, economic feasibility, and performance of these CSP using the System Advisor Model (SAM) software, which accurately models Direct Normal Irradiance (DNI), a critical factor influencing plant performance. Key parameters analyzed include Solar Multiple (SM), Thermal energy storage (TES) hours, capacity factor (CF), and the Levelized Cost of Energy (LCOE). The results demonstrate that an optimal heliostat field configuration with a SM of 1.8 and 10 h of TES achieves a capacity factor of 51.49%, with a minimum LCOE of 0.097 $/kWh. In Mechria, with operational and maintenance costs projected at 2.51 million dollars. For the Adrar region, a SM of 1.6 and TES of 2 h yield an LCOE of 0.18 $/kWh at a capacity factor of 24.03%. Similarly, in Tindouf, a SM of 1.6 and TES of 8 h result in a capacity factor of 18.95% and an LCOE of 0.17 $/kWh. The analysis reveals that the design of CSP systems, particularly the combination of solar Multiple and TES, plays a pivotal role in optimizing the economic performance of the plants, This approach enables researchers to save time and costs by using satellite-derived DNI estimations, enhancing data accuracy and optimizing CSP deployment.
- Open Access
- 21 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Synergizing NOMA and energy harvesting in full duplex mobile edge computing for optimized energy efficiency
This research introduces a novel approach to enhance energy efficiency in Mobile-Edge Computing (MEC) systems by integrating Non-Orthogonal Multiple Access (NOMA) with energy harvesting in a full-duplex (FD) environment. The primary objective is to optimize edge computing performance while minimizing energy consumption. A comprehensive resource allocation strategy is proposed, considering CPU frequency, power control for both uplink and downlink, time scheduling, and data offloading. Mobile users can offload computationally demanding tasks to MEC servers via NOMA, promoting efficient data exchange. Full-duplex base stations simultaneously manage task offloading and energy transmission, improving resource utilization. A Block Coordinate Descent (BCD)-based algorithm addresses the non-convex optimization challenge, offering an optimal solution. Simulation results demonstrate that the NOMA-assisted FD-MEC system significantly outperforms traditional Orthogonal Multiple Access and Half-Duplex approaches, leading to improved energy efficiency and reduced energy consumption. This study highlights the potential of integrating NOMA, energy harvesting, and full-duplex technologies to create more energy-efficient MEC systems.
- 21 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-20
Open AccessSynergizing NOMA and energy harvesting in full duplex mobile edge computing for optimized energy efficiency
This research introduces a novel approach to enhance energy efficiency in Mobile-Edge Computing (MEC) systems by integrating Non-Orthogonal Multiple Access (NOMA) with energy harvesting in a full-duplex (FD) environment. The primary objective is to optimize edge computing performance while minimizing energy consumption. A comprehensive resource allocation strategy is proposed, considering CPU frequency, power control for both uplink and downlink, time scheduling, and data offloading. Mobile users can offload computationally demanding tasks to MEC servers via NOMA, promoting efficient data exchange. Full-duplex base stations simultaneously manage task offloading and energy transmission, improving resource utilization. A Block Coordinate Descent (BCD)-based algorithm addresses the non-convex optimization challenge, offering an optimal solution. Simulation results demonstrate that the NOMA-assisted FD-MEC system significantly outperforms traditional Orthogonal Multiple Access and Half-Duplex approaches, leading to improved energy efficiency and reduced energy consumption. This study highlights the potential of integrating NOMA, energy harvesting, and full-duplex technologies to create more energy-efficient MEC systems.
- Open Access
- 18 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-25
Fuzzy-2 deployment in indirect vector control and hybrid space vector modulation for a two-level inverter fed induction motor drive
Soft computing based expert systems have a pivotal role to play in designing standalone mobility systems such as unmanned aerial vehicles. The expert systems are designed by learning from functional data of a system, thereby framing rules without relying on apre-defined model. The use of type-2 fuzzy (fuzzy-2) controllers instead of traditional proportional-integral controllers (PICs) enhances the dynamic performance of an indirect vector controlled (IVC) induction motor (IM) in this paper. The error tracking path (ETP) of PIC is fixed for a given set of gain constants. With the use of IF–THEN rules, the Mamdani fuzzy-2 inference system (MF2IS) processes ambiguous data and produces membership functions that work on three-dimensional inputs. Thus, controller gain constants become unfixed; thereby response attains zero error rapidly with an unfixed ETP. It is well-known that changing the switching frequency of the voltage source inverter (VSI) increases switching losses for the VSI but reducing total harmonic distortion (THD) of the line current and voltage of the IM is an important trade-off. Hence, this issue is also addressed by replacing fuzzy-2 duty cycle controller (F2DCC) in place of conventional duty cycle controller. Simulation experiments are conducted using MATLAB/SIMULINK to evaluate the efficacy of IM. The experimental validation is done on a prototype using Sacrae Theologiae Magister (STM) processor for 1 horsepower IM.
- 18 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-25
Open AccessFuzzy-2 deployment in indirect vector control and hybrid space vector modulation for a two-level inverter fed induction motor drive
Soft computing based expert systems have a pivotal role to play in designing standalone mobility systems such as unmanned aerial vehicles. The expert systems are designed by learning from functional data of a system, thereby framing rules without relying on apre-defined model. The use of type-2 fuzzy (fuzzy-2) controllers instead of traditional proportional-integral controllers (PICs) enhances the dynamic performance of an indirect vector controlled (IVC) induction motor (IM) in this paper. The error tracking path (ETP) of PIC is fixed for a given set of gain constants. With the use of IF–THEN rules, the Mamdani fuzzy-2 inference system (MF2IS) processes ambiguous data and produces membership functions that work on three-dimensional inputs. Thus, controller gain constants become unfixed; thereby response attains zero error rapidly with an unfixed ETP. It is well-known that changing the switching frequency of the voltage source inverter (VSI) increases switching losses for the VSI but reducing total harmonic distortion (THD) of the line current and voltage of the IM is an important trade-off. Hence, this issue is also addressed by replacing fuzzy-2 duty cycle controller (F2DCC) in place of conventional duty cycle controller. Simulation experiments are conducted using MATLAB/SIMULINK to evaluate the efficacy of IM. The experimental validation is done on a prototype using Sacrae Theologiae Magister (STM) processor for 1 horsepower IM.
- Open Access
- 27 February 2025
- Published by SAGE Publications in Measurement and Control
- Vol. 59 (2) , 217-231
Optimal allocation and sizing of distributed generation for improvement of distribution feeder loss and voltage profile in the distribution network using genetic algorithm
The increasing demand for electric power, coupled with rapid urbanization, necessitates a reliable and high-quality electricity supply to meet consumer expectations. However, existing passive distribution systems are inadequate to address the escalating power requirements, resulting in challenges such as increased power losses and suboptimal voltage profiles. In the base case scenario, the total active and reactive power losses were substantial, and many buses exhibited voltage magnitudes that fell outside acceptable limits. This study investigates the optimal placement and sizing of distributed generation (DG) resources to improve the performance of distribution feeders. A multi-objective optimization framework, utilizing a Genetic Algorithm (GA), was developed to minimize power losses and enhance voltage profiles. Load flow analysis was conducted using the Backward/Forward Sweep (BFS) method, allowing for precise evaluation of the distribution feeder under various DG configurations. Consequently, the study successfully enhanced the system through optimal DG allocation. Additionally, a comparative analysis was conducted to assess the performance of the proposed GA algorithm against other optimization techniques. The results indicate that, in nearly all cases, the GA method outperforms PSO by reducing system power losses and improving the voltage profile more effectively.
- 27 February 2025
- Published by SAGE Publications in Measurement and Control
- Vol. 59 (2) , 217-231
Open AccessOptimal allocation and sizing of distributed generation for improvement of distribution feeder loss and voltage profile in the distribution network using genetic algorithm
The increasing demand for electric power, coupled with rapid urbanization, necessitates a reliable and high-quality electricity supply to meet consumer expectations. However, existing passive distribution systems are inadequate to address the escalating power requirements, resulting in challenges such as increased power losses and suboptimal voltage profiles. In the base case scenario, the total active and reactive power losses were substantial, and many buses exhibited voltage magnitudes that fell outside acceptable limits. This study investigates the optimal placement and sizing of distributed generation (DG) resources to improve the performance of distribution feeders. A multi-objective optimization framework, utilizing a Genetic Algorithm (GA), was developed to minimize power losses and enhance voltage profiles. Load flow analysis was conducted using the Backward/Forward Sweep (BFS) method, allowing for precise evaluation of the distribution feeder under various DG configurations. Consequently, the study successfully enhanced the system through optimal DG allocation. Additionally, a comparative analysis was conducted to assess the performance of the proposed GA algorithm against other optimization techniques. The results indicate that, in nearly all cases, the GA method outperforms PSO by reducing system power losses and improving the voltage profile more effectively.