Jiahao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiahao Li has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jinjun Liu
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Yingjie He
School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications Longyu Xu
School of Electrical Engineering, Xian Jiaotong University, Xian, China
1 shared publication
Latest Publications
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 8577-8591
Research on the Capability of Star-Connected CHB-STATCOM to Compensate the Unbalanced Voltage of Power Grid
For the grid voltage unbalance issue, in this article, the scheme of using star-connected cascaded H-bridge static synchronous compensator (CHB-STATCOM) to suppress the unbalanced voltage at the point of common coupling (PCC) is introduced. However, the capability of star-connected CHB-STATCOM to compensate the unbalanced voltage at the PCC is limited for a certain dc-link voltage. When exceeding the effective compensation range, the star-connected CHB-STATCOM not only fails to achieve the compensation of unbalanced voltage at the PCC, but also further deteriorates the power quality of the grid. In this article, the unbalanced voltage at the PCC caused by load unbalance and power supply unbalance is considered comprehensively, the key influencing factors and quantitative relationship of the maximum output voltage of the star-connected CHB-STATCOM injecting zero-sequence voltage are analyzed in detail, and the effective compensation range of the star-connected CHB-STATCOM for unbalanced voltage at the PCC is given in a quantitative manner. These quantitative analyses provide reference limitation for star-connected CHB-STATCOM to compensate unbalanced voltage at the PCC, which is significant for real-time regulation and selection of the star-connected CHB-STATCOM. Finally, the correctness of the theoretical analysis is verified by simulation and experiment.
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 8577-8591
Research on the Capability of Star-Connected CHB-STATCOM to Compensate the Unbalanced Voltage of Power Grid
For the grid voltage unbalance issue, in this article, the scheme of using star-connected cascaded H-bridge static synchronous compensator (CHB-STATCOM) to suppress the unbalanced voltage at the point of common coupling (PCC) is introduced. However, the capability of star-connected CHB-STATCOM to compensate the unbalanced voltage at the PCC is limited for a certain dc-link voltage. When exceeding the effective compensation range, the star-connected CHB-STATCOM not only fails to achieve the compensation of unbalanced voltage at the PCC, but also further deteriorates the power quality of the grid. In this article, the unbalanced voltage at the PCC caused by load unbalance and power supply unbalance is considered comprehensively, the key influencing factors and quantitative relationship of the maximum output voltage of the star-connected CHB-STATCOM injecting zero-sequence voltage are analyzed in detail, and the effective compensation range of the star-connected CHB-STATCOM for unbalanced voltage at the PCC is given in a quantitative manner. These quantitative analyses provide reference limitation for star-connected CHB-STATCOM to compensate unbalanced voltage at the PCC, which is significant for real-time regulation and selection of the star-connected CHB-STATCOM. Finally, the correctness of the theoretical analysis is verified by simulation and experiment.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 2163-2175
Design of Hybrid Power Filters for Supraharmonics Suppression in Power Electronics Dominated Power Systems
With the rapid development of power electronics dominated power systems, the impact of supraharmonics generated by power electronic devices on power quality is becoming more and more significant, leading to supraharmonics becoming a new type of power quality problem that cannot be ignored. Current research of supraharmonics focuses on the generation mechanism, propagation mechanism, interaction effects, measurement and standardization, but no effective suppression scheme for supraharmonics has been proposed so far. This paper proposes a hybrid power filter scheme suitable for dealing with supraharmonics in low-voltage power distribution networks, which is composed of a passive part and an active part connected in series. Among them, the active part is a linear amplifier circuit with high bandwidth for supraharmonics compensation, and the passive part is used to share the grid fundamental frequency voltage drop. In this paper, it is verified through simulation and experiment that the filter scheme has significant suppression effect on supraharmonics and good dynamic performance, and the operating loss and output capacity of the active part are significantly reduced.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (2) , 2163-2175
Design of Hybrid Power Filters for Supraharmonics Suppression in Power Electronics Dominated Power Systems
With the rapid development of power electronics dominated power systems, the impact of supraharmonics generated by power electronic devices on power quality is becoming more and more significant, leading to supraharmonics becoming a new type of power quality problem that cannot be ignored. Current research of supraharmonics focuses on the generation mechanism, propagation mechanism, interaction effects, measurement and standardization, but no effective suppression scheme for supraharmonics has been proposed so far. This paper proposes a hybrid power filter scheme suitable for dealing with supraharmonics in low-voltage power distribution networks, which is composed of a passive part and an active part connected in series. Among them, the active part is a linear amplifier circuit with high bandwidth for supraharmonics compensation, and the passive part is used to share the grid fundamental frequency voltage drop. In this paper, it is verified through simulation and experiment that the filter scheme has significant suppression effect on supraharmonics and good dynamic performance, and the operating loss and output capacity of the active part are significantly reduced.