Marco Carlone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco Carlone has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Derek Hyde
BC Cancer Kelowna Kelowna British Columbia Canada
2 shared publicationsJohn Cocarell
BC Cancer Kelowna Kelowna British Columbia Canada
2 shared publicationsNathan Becker
BC Cancer Kelowna Kelowna British Columbia Canada
2 shared publicationsRay Yang
BC Cancer Kelowna Kelowna British Columbia Canada
2 shared publications- Cheryl Duzenli
Department of Medical Physics, BC Cancer, Vancouver, Canada
1 shared publication Kirpal Kohli
Department of Surgery University of British Columbia Vancouver BC Canada
1 shared publication
Latest Publications
- Open Access
- 4 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2352-2353
In reply to Masjedi et al
- 4 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (4) , 2352-2353
Open AccessIn reply to Masjedi et al
- Open Access
- 22 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14246
Linear accelerator maintenance cost analysis
Purpose: Medical linear accelerators are the most costly standard equipment used in radiation oncology, however the service costs for these machines are not well understood. With an increasing demand for linear accelerators due to a global increase in cancer incidence, it is important to understand the expected maintenance costs of a larger global installed base so that these costs can be incorporated into budgeting. The purpose of this investigation is to analyze the costs for medical linear accelerator service and maintenance at our institution, in order to estimate the service cost ratio.Methods: We collected the costs of parts used for all service work done on 32 medical linear accelerators over a two year period. The data was segregated by center, machine, linear accelerator type, and failure area in the machine.Results: We found the service cost ratio (excluding software support expenses) to be 3.13% [2.74%, 3.52%,]. We observed a variability of parts costs, and overall variability of the service cost ratio to be between 2.14% and 5.25%. This result is lower than other estimates for service costs for medical equipment in general and medical linear accelerators specifically. Two‐thirds of the service costs were due to labor costs, which indicate the importance of a well‐trained service technician workforce.Conclusions: We estimated the service cost ratio for medical linear accelerators to be 3.13% [3.52%, 2.74%] of the initial capital cost. This result was lower than other estimates of the service cost ratio.
- 22 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (2) , e14246
Open AccessLinear accelerator maintenance cost analysis
Purpose: Medical linear accelerators are the most costly standard equipment used in radiation oncology, however the service costs for these machines are not well understood. With an increasing demand for linear accelerators due to a global increase in cancer incidence, it is important to understand the expected maintenance costs of a larger global installed base so that these costs can be incorporated into budgeting. The purpose of this investigation is to analyze the costs for medical linear accelerator service and maintenance at our institution, in order to estimate the service cost ratio.Methods: We collected the costs of parts used for all service work done on 32 medical linear accelerators over a two year period. The data was segregated by center, machine, linear accelerator type, and failure area in the machine.Results: We found the service cost ratio (excluding software support expenses) to be 3.13% [2.74%, 3.52%,]. We observed a variability of parts costs, and overall variability of the service cost ratio to be between 2.14% and 5.25%. This result is lower than other estimates for service costs for medical equipment in general and medical linear accelerators specifically. Two‐thirds of the service costs were due to labor costs, which indicate the importance of a well‐trained service technician workforce.Conclusions: We estimated the service cost ratio for medical linear accelerators to be 3.13% [3.52%, 2.74%] of the initial capital cost. This result was lower than other estimates of the service cost ratio.
- 15 April 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3338-3346
Measurement of neutron yield for a medical linear accelerator below 10 MV
Background: The recent trend toward 10 MV for volumetric radiotherapy treatment such as volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic ablative body radiotherapy (SABR) introduces photoneutron production, with implications for non-therapeutic patient dose and additional shielding requirements for treatment room design. The sharply nonlinear drop-off in photoneutron production below 10 MV to negligible at 6 MV has scarcely been characterized quantitatively, yet can elucidate important practical insights.Purpose: To measure photoneutron yields in a medical linac at 8 MV, which may strike a reasonable balance between usefully increased beam penetration and dose rate as compared to 6 MV while reducing photoneutron production which is present at 10 MV.Methods: A Varian iX linear accelerator undergoing decommissioning at our clinic was made to operate over a range of photon energies between 6 and 15 MV by calibrating the bending magnet and adjusting other beam generation parameters. Neutron dose within the treatment room was measured using an Anderson-Braun type detector over a continuum of intermediate energies.Results: The photoneutron production for energies below 10 MV was measured, adding to data that is otherwise scarce in the literature. Our results are consistent with previously published results for neutron yield. We found that the photoneutron production at 8 MV was about 1/10 of the value at 10 MV, and about 10 times higher than detector background at 6 MV.Conclusions: Photoneutron production drops off below 10 MV, but is still present at 8 MV. An 8 MV beam is more penetrating than a 6 MV beam, and may offer a suitable tradeoff for modern radiotherapy techniques such as VMAT, SRS, and SABR. Further studies are needed to better understand the impact on treatment plan quality between 8 and 10 MV beams considering the benefits to facility requirements and non-therapeutic patient dose.
- 15 April 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3338-3346
Measurement of neutron yield for a medical linear accelerator below 10 MV
Background: The recent trend toward 10 MV for volumetric radiotherapy treatment such as volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic ablative body radiotherapy (SABR) introduces photoneutron production, with implications for non-therapeutic patient dose and additional shielding requirements for treatment room design. The sharply nonlinear drop-off in photoneutron production below 10 MV to negligible at 6 MV has scarcely been characterized quantitatively, yet can elucidate important practical insights.Purpose: To measure photoneutron yields in a medical linac at 8 MV, which may strike a reasonable balance between usefully increased beam penetration and dose rate as compared to 6 MV while reducing photoneutron production which is present at 10 MV.Methods: A Varian iX linear accelerator undergoing decommissioning at our clinic was made to operate over a range of photon energies between 6 and 15 MV by calibrating the bending magnet and adjusting other beam generation parameters. Neutron dose within the treatment room was measured using an Anderson-Braun type detector over a continuum of intermediate energies.Results: The photoneutron production for energies below 10 MV was measured, adding to data that is otherwise scarce in the literature. Our results are consistent with previously published results for neutron yield. We found that the photoneutron production at 8 MV was about 1/10 of the value at 10 MV, and about 10 times higher than detector background at 6 MV.Conclusions: Photoneutron production drops off below 10 MV, but is still present at 8 MV. An 8 MV beam is more penetrating than a 6 MV beam, and may offer a suitable tradeoff for modern radiotherapy techniques such as VMAT, SRS, and SABR. Further studies are needed to better understand the impact on treatment plan quality between 8 and 10 MV beams considering the benefits to facility requirements and non-therapeutic patient dose.