FCFlorent Cosandier

Florent Cosandier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Florent Cosandier has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimized design of generalized flexure rotational couplers

    by Célestin Vallat, Loïc Tissot-Daguette, Florent Cosandier, Simon Henein


  • Open Access

    Near-Zero Parasitic Shift Rectilinear Flexure Stages Based on Coupled n-RRR Planar Parallel Mechanisms

    by Loïc Tissot-Daguette, Célestin Vallat, Marijn Nijenhuis, Florent Cosandier, Simon Henein

    Flexure-based linear stages have become prevalent in precision engineering; however, most designs suffer from parasitic shifts that degrade positioning accuracy. Conventional solutions to mitigate these parasitic motions often compromise support stiffness, reduce motion range, and increase structural complexity. This study presents a novel family of flexure-based rectilinear-motion stages using coupled n-RRR planar parallel mechanisms, achieving extremely low parasitic shifts while addressing the forementioned limitations. Four design variants are selected and analyzed via Finite Element Method (FEM) simulations, evaluating parasitic shifts, stroke, and support stiffness. The most precise configuration, a 4-RRR rectilinear stage having kinematic chains coupled via two Watt linkages, exhibits a lateral shift smaller than 0.258 µm and an in-plane parasitic rotation smaller than 12.6 µrad over a 12 mm stroke. Experimental validation using a POM prototype confirms the high positioning precision and support stiffness properties. In addition, a silicon prototype incorporating thermally preloaded buckling beams is investigated to reduce its translational stiffness. Experimental results show a translational stiffness reduction of 98% in the monostable configuration and 112% in the bistable configuration (i.e., negative stiffness), without support stiffness reduction. These results highlight the potential of the proposed mechanisms for a wide range of precision applications, offering a scalable and high-accuracy solution for micro- and nano-positioning systems.


  • Open Access

    Residual stress chevron preloading amplifier for large-stroke stiffness reduction of silicon flexure mechanisms

    by Loïc Tissot-Daguette, Florent Cosandier, Quentin Gubler, Yves Pétremand, Michel Despont, Simon Henein

    Residual stresses can be advantageously used to permanently preload flexure micro-mechanisms in order to modify their deflection and stiffness. This paper presents a new preloading chevron mechanism (PCM) used to amplify the preloading effect of thin film residual stress. To evaluate the preloading performances of this structure, the deflection characteristics of buckled beams and flexure linear stages preloaded by a PCM is investigated experimentally. All the mechanisms are manufactured from a monocrystalline silicon substrate using deep reactive ion etching and residual stress is provided by wet thermal oxidation. Measurements show that the deflection magnitude of fixed-fixed oxidized silicon buckled beams can be increased by up to 5 times when a PCM is integrated. The flexure linear stages studied in this research are composed of a parallel leaf spring stage connected to two fixed-guided buckled beams preloaded by a PCM. Depending on the beam dimensions, the stage translational stiffness can be set to a specific value. We designed a near-zero positive stiffness linear stage revealing a measured stiffness reduction of 98%, and a bistable linear stage with a constant negative stiffness region. Thanks to the elevated preloading displacement supplied by the PCM, the operating stroke (actuation region where the stiffness remains constant) is relatively large (more than 0.4 mm travel for 2.59 mm leaf spring length). The analytical and numerical models carried out to design the mechanisms are in good agreement with the experimental data. The results show that the fixed frame stiffness has a significant effect on the preloading performances due to the substantial forces exerted by the PCM. Furthermore, the presented preloading concept, modeling and sizing method could be applied to other compliant mechanism designs, scales and materials, enabling applications in microelectromechanical systems and watchmaking.


  • Near-Zero Parasitic Shift Flexure Pivots Based on Coupled n-RRR Planar Parallel Mechanisms

    by Loïc Tissot-Daguette, Florent Cosandier, Etienne Thalmann, Simon Henein

    Flexure pivots, which are widely used for precision mechanisms, generally have the drawback of presenting parasitic shifts accompanying their rotation. The known solutions for canceling these undesirable parasitic translations usually induce a loss in radial stiffness, a reduction of the angular stroke, and nonlinear moment–angle characteristics. This article introduces a novel family of kinematic structures based on coupled n-RRR planar parallel mechanisms, which presents exact zero parasitic shifts while alleviating the drawbacks of some known pivoting structures. Based on this invention, three symmetrical architectures have been designed and implemented as flexure-based pivots. The performance of the newly introduced pivots has been compared with two known planar flexure pivots having theoretically zero parasitic shift via Finite Element models and experiments performed on plastic mockups. The results show that the newly introduced flexure pivots are an order of magnitude radially stiffer than the considered pivots from the state-of-the-art while having equivalent angular strokes. To experimentally evaluate the parasitic shift of the novel pivots, one of the architectures was manufactured in titanium alloy using wire-cut electrical discharge machining. This prototype exhibits a parasitic shift under 1.5 µm over a rotation stroke of ±15 deg, validating the near-zero parasitic shift properties of the presented designs. These advantages are key to applications such as mechanical time bases, surgical robotics, or optomechanical mechanisms.


  • Open Access

    Design of a Flexure-Based Flywheel for the Storage of Angular Momentum and Kinetic Energy

    by Patrick Flückiger, Florent Cosandier, Hubert Schneegans, Simon Henein

    The flywheel is a widespread mechanical component used for the storage of kinetic energy and angular momentum. It typically consists of cylindrical inertia rotating about its axis on rolling bearings, which involves undesired friction, lubrication, and wear. This paper presents an alternative mechanism that is functionally equivalent to a classical flywheel while relying exclusively on limited-stroke flexure joints. This novel one-degree-of-freedom zero-force mechanism has no wear and requires no lubrication: it is thus compatible with extreme environments, such as vacuum, cryogenics, or ionizing radiation. The mechanism is composed of two coupled pivoting rigid bodies whose individual angular momenta vary during motion but whose sum is constant at all times when the pivoting rate is constant. The quantitative comparison of the flexure-based flywheel to classical ones based on a hollow cylinder as inertia shows that the former typically stores 6 times less angular momentum and kinetic energy for the same mass while typically occupying 10 times more volume. The freedom of design of the shape of the rigid bodies offers the possibility of modifying the ratio of the stored kinetic energy versus angular momentum, which is not possible with classical flywheels. For example, a flexure-based flywheel with rigid pivoting bodies in the shape of thin discs stores 100 times more kinetic energy than a classical flywheel with the same angular momentum. A proof-of-concept prototype was successfully built and characterized in terms of reaction moment generation, which validates the presented analytical model.


  • Open Access

    Design of a Flexure-based Flywheel for Storage of Angular Momentum and Kinetic Energy

    by Patrick Flückiger, Florent Cosandier, Hubert Schneegans, Simon Henein

    The flywheel is a widespread mechanical component used for the storage of kinetic energy and angular momentum. It typically consists of a cylindrical inertia rotating about its axis on rolling bearings, which involves undesired friction, lubrication, and wear. This paper presents an alternative mechanism that is functionally equivalent to a classical flywheel while relying exclusively on limited-stroke flexure-joints. This novel 1-degrees-of-freedom zero-stiffness mechanism has no wear and requires no lubrication: it is thus compatible with extreme environments, such as vacuum, cryogenics, or ionizing radiation. The mechanism is composed of two coupled pivoting rigid bodies whose individual angular momenta vary during motion but whose sum is constant at all times when the pivoting rate is constant. The quantitative comparison of the flexure-based flywheel to classical ones based on a hollow cylinder as inertia shows that the former stores typically 6 times less angular momentum and kinetic energy for the same mass while occupying typically 10 times more volume. The freedom of design of the shape of the rigid bodies offers the possibility of modifying the ratio of the kinetic energy stored versus angular momentum, which is not possible with classical flywheels. For example, a flexure-based flywheel with rigid pivoting bodies in the shape of thin discs stores 100 times more kinetic energy than a classical flywheel with the same angular momentum. A proof-of-concept prototype was successfully built and characterized in terms of reaction moment generation, which validates the presented analytical model.