Xingjian Li
Xingjian Li has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Xuguo Zhang
Beijing Institute of Space Mechanics and Electricity, Beijing, China
2 shared publications- Bizhong Xia
Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China.
1 shared publication - Gaojin Wen
Beijing Institute of Space Mechanics and Electricity, Beijing, China
1 shared publication Haibei Wang
Institute of Data and Information, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
1 shared publicationHaoqing Dong
Beijing Institute of Space Mechanics and Electricity, Beijing, China
1 shared publication- Kai Yu
School of Instrumentation Science & Opto-Electronics Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100191, China
1 shared publication
Latest Publications
- Open Access
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (2) , 1-8
RANSAC-Enhanced Calibration of Alignment Errors in Acousto-Optic Tunable Filter Imaging Systems
Accurate calibration of alignment errors is critical for model-based spectral correction in acousto-optic tunable filter (AOTF) imaging systems, especially for wide field-of-view applications. In practice, experimental frequency response data are often contaminated by outliers originating from laser instability, field-dependent diffraction efficiency variations, and non-ideal peak fitting, which severely bias conventional least-squares estimation due to the strong nonlinearity between alignment errors and image-plane frequency responses. In this work, we demonstrate that coupled alignment errors give rise to a structured single-minimum frequency response surface governed by system geometry, and exploit this physical constraint to develop a model-guided robust calibration framework. A Random sample consensus (RANSAC)-based estimation strategy is employed to identify and exclude outlier measurements without assuming a specific noise distribution, followed by constrained least-squares optimization on the purified dataset. Experimental validation on a collimated mid-wave infrared AOTF imaging system shows that the full-field frequency response modeling error is reduced from 2.4% to below 0.3% after calibration. The proposed method significantly enhances the robustness and accuracy of alignment error compensation, providing a practical solution for high-precision AOTF spectroscopic imaging under real-world measurement uncertainties.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 18 (2) , 1-8
Open AccessRANSAC-Enhanced Calibration of Alignment Errors in Acousto-Optic Tunable Filter Imaging Systems
Accurate calibration of alignment errors is critical for model-based spectral correction in acousto-optic tunable filter (AOTF) imaging systems, especially for wide field-of-view applications. In practice, experimental frequency response data are often contaminated by outliers originating from laser instability, field-dependent diffraction efficiency variations, and non-ideal peak fitting, which severely bias conventional least-squares estimation due to the strong nonlinearity between alignment errors and image-plane frequency responses. In this work, we demonstrate that coupled alignment errors give rise to a structured single-minimum frequency response surface governed by system geometry, and exploit this physical constraint to develop a model-guided robust calibration framework. A Random sample consensus (RANSAC)-based estimation strategy is employed to identify and exclude outlier measurements without assuming a specific noise distribution, followed by constrained least-squares optimization on the purified dataset. Experimental validation on a collimated mid-wave infrared AOTF imaging system shows that the full-field frequency response modeling error is reduced from 2.4% to below 0.3% after calibration. The proposed method significantly enhances the robustness and accuracy of alignment error compensation, providing a practical solution for high-precision AOTF spectroscopic imaging under real-world measurement uncertainties.
- Open Access
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19662-19669
High-Frequency Subpixel Vibration Measurement Based on Compressed Sensing
High-speed camera measurement technology is widely employed in sound recovery, contactless structural monitoring, fault diagnosis, digital soil mapping, and other fields. High-speed image sequences are utilized to recover minute high-frequency signals that would otherwise be ignored. However, high-speed image sequence also imposes significant pressure on data transmission and processing. In certain scenarios, achieving high-speed camera measurement with limited bandwidth is nearly impossible. In this article, high-frequency subpixel vibration measurement based on compressed sensing (HSVM-CS) is introduced, which utilizes sparse samplings from the image sequence to extract vibration signals and reconstruct the complete high-frequency vibration signal. Through both simulation and experimentation, we demonstrate our ability to recover the original high-frequency signal ranging from 0 to 499 Hz at a sampling ratio of 0.3 in both the X- and Y-directions. The peak signal-to-noise ratio (PSNR) of the recovered 3-D signals reaches 21 dB. Furthermore, the adaptive sampling strategy based on signal entropy is employed to allocate samplings reasonably, thereby enhancing the accuracy of recovery signals at a consistent sampling rate.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19662-19669
Open AccessHigh-Frequency Subpixel Vibration Measurement Based on Compressed Sensing
High-speed camera measurement technology is widely employed in sound recovery, contactless structural monitoring, fault diagnosis, digital soil mapping, and other fields. High-speed image sequences are utilized to recover minute high-frequency signals that would otherwise be ignored. However, high-speed image sequence also imposes significant pressure on data transmission and processing. In certain scenarios, achieving high-speed camera measurement with limited bandwidth is nearly impossible. In this article, high-frequency subpixel vibration measurement based on compressed sensing (HSVM-CS) is introduced, which utilizes sparse samplings from the image sequence to extract vibration signals and reconstruct the complete high-frequency vibration signal. Through both simulation and experimentation, we demonstrate our ability to recover the original high-frequency signal ranging from 0 to 499 Hz at a sampling ratio of 0.3 in both the X- and Y-directions. The peak signal-to-noise ratio (PSNR) of the recovered 3-D signals reaches 21 dB. Furthermore, the adaptive sampling strategy based on signal entropy is employed to allocate samplings reasonably, thereby enhancing the accuracy of recovery signals at a consistent sampling rate.
- Open Access
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-6
Aberration Correction and Speckle Noise Reduction in Image Minified Lensless Holographic Projection Based on Digital Micro-Mirror Device
Lensless holographic projection technology allows for removing of the projection lens and simplifies the optical projection system. It has great potential to be applied in the fields of three-dimensional printing, integrated circuit fabrication, and display. In this paper, for image minified lensless holographic projection based on digital micro-mirror device (DMD), we examine the aberration that arises from the use of the DMD in the presence of oblique converging spherical wave illumination. To correct this aberration, we employ a diagonal compression technique on the target pattern. Additionally, we address the issue of speckle noise by relaxing the amplitude constraint in the non-signal domain, which is generated by our proposed aberration correction method. Importantly, this relaxation is achieved without reducing the size of the valid image. Our experimental results demonstrate the successful reconstruction of high-quality images in a lensless holographic projection system.
- 16 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (1) , 1-6
Open AccessAberration Correction and Speckle Noise Reduction in Image Minified Lensless Holographic Projection Based on Digital Micro-Mirror Device
Lensless holographic projection technology allows for removing of the projection lens and simplifies the optical projection system. It has great potential to be applied in the fields of three-dimensional printing, integrated circuit fabrication, and display. In this paper, for image minified lensless holographic projection based on digital micro-mirror device (DMD), we examine the aberration that arises from the use of the DMD in the presence of oblique converging spherical wave illumination. To correct this aberration, we employ a diagonal compression technique on the target pattern. Additionally, we address the issue of speckle noise by relaxing the amplitude constraint in the non-signal domain, which is generated by our proposed aberration correction method. Importantly, this relaxation is achieved without reducing the size of the valid image. Our experimental results demonstrate the successful reconstruction of high-quality images in a lensless holographic projection system.