HZHekuan Zhou

Hekuan Zhou

*This is an algorithmically generated author record based on publicly available information.

Hekuan Zhou has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Dynamic Mechanical Properties of Steel-Fiber-Reinforced Concrete Subjected to Freeze–Thaw Cycles

    by Ruijun Wang, Nan Tian, Jun Liu, Ruibao Jin, Gang Liang, Yan Li, Jing Hu, Hekuan Zhou, Yaofei Jia, Yanxiong Liu

    This study investigates the structural characteristics of SFRC with different amounts of steel fibers following exposure to freeze–thaw cycles, while taking into account various levels of confinement pressure and rates of deformation. The focus of the research is to examine the dynamic mechanical properties of SFRC exposed to freeze–thaw cycles. The inclusion of steel fibers improves the strength of concrete during freeze–thaw cycles, with 1% steel fiber content being the most effective. Strain rate and confining pressure significantly impact the strength and failure mode of SFRC. The strength of concrete increases linearly with the strain rate. With no confining pressure, the cracks in the concrete specimen align with the direction of the applied stress. And with confining pressure, concrete exhibits diagonal shear failure. Microstructural analysis results from scanning electron microscopy are consistent with the macroscopic properties.


  • Open Access

    Mesoscopic Numerical Simulation of Freeze–Thaw Damage in Hydraulic Concrete

    by Ruijun Wang, Yunhui Liu, Jun Liu, Yang Li, Ruibao Jin, Gang Liang, Ningning Yu, Jing Hu, Hekuan Zhou, Yaofei Jia, et al.

    To investigate the impact of freeze–thaw damage on the mechanical properties of concrete, this study utilized Python in combination with ABAQUS 2016 to generate a two-dimensional meso-scale model of concrete. Uniaxial compression tests were conducted on the concrete after freeze–thaw cycles to study the evolution of its mechanical properties. Using “relative compressive strength” as a variable, the relationships between this variable and the parameters of the freeze–thaw damage model were determined, leading to the establishment of the freeze–thaw damage model and the simulation of compressive tests on concrete after freeze–thaw cycles. This study also explored the changes in the mechanical properties of concrete with variations in ITZ parameters and coarse aggregate content. The conclusions drawn are as follows: A comparison with experimental data showed that the model ensures that the relative error of each mechanical property parameter does not exceed 7%, verifying the model’s rationality. Increasing the ratio of ITZ parameters improved the mechanical properties of the ITZ, enhancing the overall mechanical performance, but had almost no effect on the elastic modulus. Compared to ratios of 0.7 and 0.8, concrete with a ratio of 0.9 showed slower rates of decrease in compressive strength and elastic modulus and slower rates of increase in peak compressive strain after freeze–thaw cycles. The increase in coarse aggregate content had a similar effect on the strength and freeze–thaw resistance of concrete as the ratio of ITZ parameters. Concrete with a coarse aggregate content of 60% exhibited slower rates of change in mechanical properties after freeze–thaw cycles.


  • Open Access

    Reasonable Energy-Abandonment Operation of a Combined Power Generation System with an Ultra-High Proportion of Renewable Energy

    by Hao Zhang, Jingyue Yang, Chenxi Li, Pengcheng Guo, Jun Liu, Ruibao Jin, Jing Hu, Fengyuan Gan, Fei Cao

    With large-scale grid-connected renewable energy, new power systems require more flexible and reliable energy storage power sources. Pumped storage stations play an important role in peak shaving, valley filling, and promoting renewable energy consumption. This paper presents the reasonable energy-abandonment operation of a combined power generation system (CPGS), in which a pumped storage station is the core control power, with an ultra-high proportion of renewable energy. Firstly, based on the seasonal characteristics of wind, solar, and load demand, typical days are selected through improved clustering analysis algorithms. Then, a daily optimal scheduling model for combined power generation systems (CPGS) is developed with the goals of economy, low-carbon, and stable operation. Finally, the correlation between the energy-abandonment rate and pumped storage station peak shaving and system optimization operation indicators is obtained by a reasonable energy-abandonment calculation method considering source-grid-load coordination. Taking the operation data of an energy base in the western region of China as an example, when the penetration rate of renewable energy is 60–70% in the future, the operating cost on the power side is greatly affected by the construction of the source side. When the system operates at a planned reasonable energy-abandonment rate of 2%, electricity regulation, load tracking, and daily operating costs all show better performance.


  • Open Access

    Multi-Scheme Optimal Operation of Pumped Storage Wind–Solar–Thermal Generation System Based on Tolerable Energy Abandonment

    by Hao Zhang, Shuai Wu, Huanhuan Li, Jie Zhang, Chao Zhu, Hekuan Zhou, Yaofei Jia

    In multi-energy complementary power generation systems, the complete consumption of wind and photovoltaic resources often requires more costs, and tolerable energy abandonment can bring about the more reasonable optimization of operation schemes. This paper presents a scheduling model for a combined power generation system that incorporates pumped storage, wind, solar, and fire energy sources. Through a comparison of schemes, the energy regulation function of the pumped storage power station was verified and analyzed. The CPLEX solver and MOPSO algorithm were employed to solve the daily output of a pumped storage power station in the Gansu region under various scenarios. The incorporation of pumped storage power plants has the potential to provide many benefits, including a reduction in operating expenses by about CNY 1.1163 million, a decrease in carbon emissions by 491.24 t, an enhancement in the stability of thermal power by 2.39%, and an improvement in the combined system capability to absorb additional energy. The correlation between the indicators of the combined system and the penetration rate of renewable energy is non-linearly influenced by changes in the power capacity configuration. Ultimately, the multi-objective optimization computation yields the ideal operational scheme for each power source, taking into account a tolerable energy abandonment mode.