Kenichi Akao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kenichi Akao has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Akio Kaneta
CD & Polarimeter System Group JASCO Corporation Tokyo Japan
2 shared publications- Naoto Ishikawa
Department of Chemistry, Graduate School of Science Osaka University Osaka Japan
2 shared publications - Satoko Suzuki
Department of Chemistry, Graduate School of Science Osaka University Osaka Japan
2 shared publications - Aiko Sano
Laboratory of Natural Products and Phytochemistry, Faculty of Pharmacy and Pharmaceutical Sciences, Josai University, 1-1 Keyakidai, Sakado 3500295, Saitama, Japan
1 shared publication Anas Santria
Department of Chemistry, Graduate School of Science Osaka University Osaka Japan
1 shared publication- Anas Santria
The University of Osaka 1-1 Machikaneyamacho
1 shared publication
Latest Publications
Automated Evaluation Method for Aggregation‐Induced Circularly Polarized Luminescence of Platinum(II) Complexes With 1,1′‐Bi‐2‐naphthol Derivatives as Ligands
Luminogens exhibiting aggregation‐induced circularly polarized luminescence (AICPL) properties have garnered significant attention in recent years due to their promising applications in optoelectronics and biomedical research. Typically, aggregation‐induced emission (AIE) is evaluated by measuring luminescence spectra using a spectrofluorometer while varying the volume ratio of a poor to a good solvent, whereas circularly polarized luminescence (CPL) is assessed separately using a CPL spectrometer. However, these conventional methods rely on manual operation, which may lead to operational errors, particularly when processing a large number of samples. Furthermore, cases often occur where AIE is observed while CPL is not, suggesting that simultaneous measurement of both phenomena will enhance the efficiency of AICPL characterization. In this study, we demonstrate the applicability of an automated high‐throughput CPL system capable of simultaneously obtaining CPL and luminescence spectra of multiple samples for the purpose of AICPL evaluation. We assess the measurement reproducibility of the system, compare the AICPL properties of enantiomers, and investigate the influence of various substituents on chiral platinum(II) complexes. The results obtained collectively demonstrate that this method offers an efficient and reliable approach to the comprehensive evaluation of AICPL properties.
Automated Evaluation Method for Aggregation‐Induced Circularly Polarized Luminescence of Platinum(II) Complexes With 1,1′‐Bi‐2‐naphthol Derivatives as Ligands
Luminogens exhibiting aggregation‐induced circularly polarized luminescence (AICPL) properties have garnered significant attention in recent years due to their promising applications in optoelectronics and biomedical research. Typically, aggregation‐induced emission (AIE) is evaluated by measuring luminescence spectra using a spectrofluorometer while varying the volume ratio of a poor to a good solvent, whereas circularly polarized luminescence (CPL) is assessed separately using a CPL spectrometer. However, these conventional methods rely on manual operation, which may lead to operational errors, particularly when processing a large number of samples. Furthermore, cases often occur where AIE is observed while CPL is not, suggesting that simultaneous measurement of both phenomena will enhance the efficiency of AICPL characterization. In this study, we demonstrate the applicability of an automated high‐throughput CPL system capable of simultaneously obtaining CPL and luminescence spectra of multiple samples for the purpose of AICPL evaluation. We assess the measurement reproducibility of the system, compare the AICPL properties of enantiomers, and investigate the influence of various substituents on chiral platinum(II) complexes. The results obtained collectively demonstrate that this method offers an efficient and reliable approach to the comprehensive evaluation of AICPL properties.
Construction of high‐throughput magnetic circular dichroism measurement system and its application to research on magnetic and optical properties of phthalocyanine complexes
Magnetic circular dichroism (MCD) spectroscopy is a powerful method for evaluating the electronic structure and magnetic and optical properties of molecules. In particular, MCD measurements have been performed on phthalocyanines and porphyrins with various central metal ions, axial ligands, and substituents to elucidate their properties. It is essential to develop a robust high‐throughput technique to perform these measurements comprehensively and efficiently. However, MCD spectroscopy requires very high optical quality for each component of the instrument, and even slight cell distortions can impair the baseline flatness. Consequently, when versatility and data quality are important, an optical system designed for a microplate reader is not suitable for the MCD spectrometer. Therefore, in this study, we develop a new magnetic flow‐through cell and combine it with an existing CD spectrometer and autosampler to construct a high‐throughput system. The effectiveness and performance of this new system are then evaluated. In addition, based on the MCD and absorption spectra of various phthalocyanine complexes, the effects of substituents and solvents on their magnetic and optical properties and the causes of these effects are discussed. The results demonstrate that this system is effective for the evaluation of the physicochemical properties of various phthalocyanine complexes.
Construction of high‐throughput magnetic circular dichroism measurement system and its application to research on magnetic and optical properties of phthalocyanine complexes
Magnetic circular dichroism (MCD) spectroscopy is a powerful method for evaluating the electronic structure and magnetic and optical properties of molecules. In particular, MCD measurements have been performed on phthalocyanines and porphyrins with various central metal ions, axial ligands, and substituents to elucidate their properties. It is essential to develop a robust high‐throughput technique to perform these measurements comprehensively and efficiently. However, MCD spectroscopy requires very high optical quality for each component of the instrument, and even slight cell distortions can impair the baseline flatness. Consequently, when versatility and data quality are important, an optical system designed for a microplate reader is not suitable for the MCD spectrometer. Therefore, in this study, we develop a new magnetic flow‐through cell and combine it with an existing CD spectrometer and autosampler to construct a high‐throughput system. The effectiveness and performance of this new system are then evaluated. In addition, based on the MCD and absorption spectra of various phthalocyanine complexes, the effects of substituents and solvents on their magnetic and optical properties and the causes of these effects are discussed. The results demonstrate that this system is effective for the evaluation of the physicochemical properties of various phthalocyanine complexes.
- Open Access
Characterization of Carbohydrates, Amino Acids, Viscosity, and Antioxidant Capacity in Rice Wines Made in Saitama, Japan, with Different Sake Rice
We investigated the physicochemical properties of Japanese rice wines, including their functional properties and carbohydrate and amino acid content in solution and solid state. Three samples were tested. The glucose, allose, and raffinose contents in samples (A, B, C) in g/100 g were (3.47, 3.45, 7.05), (1.60, 1.63, 1.61), and (2.14, 2.75, 1.49), respectively. The total amino acid in µmol/mL was (3.1, 3.5, 4.4). Glutamic acid, alanine, and arginine varied in content across the samples. The viscosity (10 °C) and activation energy (ΔE) calculated using the Andrade equation were (2.81 ± 0.03, 2.74 ± 0.06, 2.69 ± 0.03) mPa-s and (22.3 ± 1.1, 22.0 ± 0.2, 21.3 ± 0.5) kJ/mol, respectively. Principal component analysis using FT-IR spectra confirmed the separation of the samples into principal components 2 and 3. The IC50 values from the DPPH radical scavenging test were (2364.7 ± 185.3, 3041.9 ± 355.1, 3842.7 ± 228.1) µg/mL. Thus, the three rice wines had different carbohydrate and amino acid contents, viscosities, and antioxidant capacities.
Open AccessCharacterization of Carbohydrates, Amino Acids, Viscosity, and Antioxidant Capacity in Rice Wines Made in Saitama, Japan, with Different Sake Rice
We investigated the physicochemical properties of Japanese rice wines, including their functional properties and carbohydrate and amino acid content in solution and solid state. Three samples were tested. The glucose, allose, and raffinose contents in samples (A, B, C) in g/100 g were (3.47, 3.45, 7.05), (1.60, 1.63, 1.61), and (2.14, 2.75, 1.49), respectively. The total amino acid in µmol/mL was (3.1, 3.5, 4.4). Glutamic acid, alanine, and arginine varied in content across the samples. The viscosity (10 °C) and activation energy (ΔE) calculated using the Andrade equation were (2.81 ± 0.03, 2.74 ± 0.06, 2.69 ± 0.03) mPa-s and (22.3 ± 1.1, 22.0 ± 0.2, 21.3 ± 0.5) kJ/mol, respectively. Principal component analysis using FT-IR spectra confirmed the separation of the samples into principal components 2 and 3. The IC50 values from the DPPH radical scavenging test were (2364.7 ± 185.3, 3041.9 ± 355.1, 3842.7 ± 228.1) µg/mL. Thus, the three rice wines had different carbohydrate and amino acid contents, viscosities, and antioxidant capacities.
- 1 January 2008
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 62 (1) , 17-23
Time-Resolved Step-Scan Infrared Imaging System Utilizing a Linear Array Detector
A time-resolved infrared (IR) imaging system combined with a multichannel IR microscope, which utilizes a 16 channel linear array (LA) detector, and step-scan Fourier transform infrared (FT-IR) microscope was developed. The LA detector integrates a readout circuit on each detector element, so the detected signals can be read simultaneously. Thus, this system can perform high speed imaging using the step-scan method, similar to a single channel detector. To verify the capabilities of this system, a reflective sample was examined whose position was altered using a piezo actuator activated by an alternating voltage. In addition, the localization of relaxation dynamics for the liquid crystal (LC) molecules in an LC cell under oscillating electric field conditions was detected by this system.
- 1 January 2008
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 62 (1) , 17-23
Time-Resolved Step-Scan Infrared Imaging System Utilizing a Linear Array Detector
A time-resolved infrared (IR) imaging system combined with a multichannel IR microscope, which utilizes a 16 channel linear array (LA) detector, and step-scan Fourier transform infrared (FT-IR) microscope was developed. The LA detector integrates a readout circuit on each detector element, so the detected signals can be read simultaneously. Thus, this system can perform high speed imaging using the step-scan method, similar to a single channel detector. To verify the capabilities of this system, a reflective sample was examined whose position was altered using a piezo actuator activated by an alternating voltage. In addition, the localization of relaxation dynamics for the liquid crystal (LC) molecules in an LC cell under oscillating electric field conditions was detected by this system.