Yusuke Nomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yusuke Nomura has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Taiichi Sakamoto
Chiba Institute of Technology
2 shared publications Yuji Haishima
Division of Medical Devices National Institute of Health Sciences Kawasaki Kanagawa Japan
2 shared publicationsAtsushi Kaneki
Evaluation Center Terumo Corporation Ashigarakami‐gun Kanagawa Japan
1 shared publicationChie Fukui
Division of Medical Devices National Institute of Health Sciences Kawasaki Kanagawa Japan
1 shared publication- Chie Fukui
Division of Medical Devices, National Institute of Health Sciences, 1-18-1 Kamiyoga, Setagaya-ku, Tokyo 158-8501, Japan
1 shared publication Eiichi Yamamoto
Division of Medical Devices National Institute of Health Sciences Kawasaki Kanagawa Japan
1 shared publication
Latest Publications
- Open Access
- 20 November 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (11) , 1480
Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results
Background: This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). Methods: Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load–displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. Results: The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. Conclusions: Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.
- 20 November 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (11) , 1480
Open AccessMechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results
Background: This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). Methods: Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load–displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. Results: The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. Conclusions: Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.
- Open Access
- 9 February 2024
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 112 (2) , e35386
Proof of concept testing of a positive reference material for in vivo and in vitro sensitization testing of medical devices
In vivo skin sensitization tests are required to evaluate the biological safety of medical devices in contact with living organisms to provide safe medical care to patients. Negative and positive reference materials have been developed for biological tests of cytotoxicity, implantation, hemolysis, and in vitro skin irritation. However, skin sensitization tests are lacking. In this study, polyurethane sheets containing 1 wt/wt % 2,4‐dinitrochlorobenzene (DNCB‐PU) were developed and evaluated as a positive reference material for skin sensitization tests. DNCB‐PU sheet extracts prepared with sesame oil elicited positive sensitization responses for in vivo sensitization potential in the guinea pig maximization test and the local lymph node assay. Furthermore, DNCB‐PU sheet extracts prepared with water and acetonitrile, 10% fetal bovine serum‐containing medium, or sesame oil elicited positive sensitization responses as alternatives to animal testing based on the amino acid derivative reactivity assay, human cell line activation test, and epidermal sensitization assay, respectively. These data suggest that the DNCB‐PU sheet is an effective extractable positive reference material for in vivo and in vitro skin sensitization testing in medical devices. The formulation of this reference material will lead to the development of safer medical devices that contribute to patient safety.
- 9 February 2024
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 112 (2) , e35386
Open AccessProof of concept testing of a positive reference material for in vivo and in vitro sensitization testing of medical devices
In vivo skin sensitization tests are required to evaluate the biological safety of medical devices in contact with living organisms to provide safe medical care to patients. Negative and positive reference materials have been developed for biological tests of cytotoxicity, implantation, hemolysis, and in vitro skin irritation. However, skin sensitization tests are lacking. In this study, polyurethane sheets containing 1 wt/wt % 2,4‐dinitrochlorobenzene (DNCB‐PU) were developed and evaluated as a positive reference material for skin sensitization tests. DNCB‐PU sheet extracts prepared with sesame oil elicited positive sensitization responses for in vivo sensitization potential in the guinea pig maximization test and the local lymph node assay. Furthermore, DNCB‐PU sheet extracts prepared with water and acetonitrile, 10% fetal bovine serum‐containing medium, or sesame oil elicited positive sensitization responses as alternatives to animal testing based on the amino acid derivative reactivity assay, human cell line activation test, and epidermal sensitization assay, respectively. These data suggest that the DNCB‐PU sheet is an effective extractable positive reference material for in vivo and in vitro skin sensitization testing in medical devices. The formulation of this reference material will lead to the development of safer medical devices that contribute to patient safety.
- Open Access
- 1 June 2018
- Published by Elsevier in Regenerative Therapy
- Vol. 8, 46-57
A biological study establishing the endotoxin limit for osteoblast and adipocyte differentiation of human mesenchymal stem cells
- 1 June 2018
- Published by Elsevier in Regenerative Therapy
- Vol. 8, 46-57
Open AccessA biological study establishing the endotoxin limit for osteoblast and adipocyte differentiation of human mesenchymal stem cells
- Open Access
- 14 July 2017
- Published by Oxford University Press (OUP) in The Journal of Biochemistry
- Vol. 162 (6) , 431-436
Conjugation of two RNA aptamers improves binding affinity to AML1 Runt domain
To develop a high-affinity aptamer against AML1 Runt domain, two aptamers were conjugated based on their structural information. The newly designed aptamer Apt14 was generated by the conjugation of two RNA aptamers (Apt1 and Apt4) obtained by SELEX against AML1 Runt domain, resulting in improvement in its binding performance. The residues of AML1 Runt domain in contact with Apt14 were predicted in silico and confirmed by mutation and NMR analyses. It was suggested that the conjugated internal loop renders additional contacts and is responsible for the enhancement in the binding affinity. Conjugation of two aptamers that bind to different sites of the target protein is a facile and robust strategy to develop an aptamer with higher performance.
- 14 July 2017
- Published by Oxford University Press (OUP) in The Journal of Biochemistry
- Vol. 162 (6) , 431-436
Open AccessConjugation of two RNA aptamers improves binding affinity to AML1 Runt domain
To develop a high-affinity aptamer against AML1 Runt domain, two aptamers were conjugated based on their structural information. The newly designed aptamer Apt14 was generated by the conjugation of two RNA aptamers (Apt1 and Apt4) obtained by SELEX against AML1 Runt domain, resulting in improvement in its binding performance. The residues of AML1 Runt domain in contact with Apt14 were predicted in silico and confirmed by mutation and NMR analyses. It was suggested that the conjugated internal loop renders additional contacts and is responsible for the enhancement in the binding affinity. Conjugation of two aptamers that bind to different sites of the target protein is a facile and robust strategy to develop an aptamer with higher performance.
- 1 January 2006
- Published by The Spectroscopical Society of Japan in Journal of the Spectroscopical Society of Japan
- Vol. 55 (4) , 252-258
Effect of Two Steps Refinement on the RNA Structure Determination by the NMR Method Using the Residual Dipolar Couplings
- 1 January 2006
- Published by The Spectroscopical Society of Japan in Journal of the Spectroscopical Society of Japan
- Vol. 55 (4) , 252-258
Effect of Two Steps Refinement on the RNA Structure Determination by the NMR Method Using the Residual Dipolar Couplings