Henry R. Boucher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Henry R. Boucher has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Brian P. McCormick
Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA
2 shared publications - Eshetu Tefera
MedStar Health Research Institute, MedStar Georgetown University Hospital, Washington, DC 20007, USA
2 shared publications - Alexander V. Strait
Georgetown University School of Medicine, Washington, DC
1 shared publication - Brett D. Haislup
Department of Shoulder and Elbow Surgery MedStar Union Memorial Hospital Baltimore Maryland USA
1 shared publication Brian McCormick
Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD
1 shared publication- Casey Imbergamo
MedStar Orthopaedic Institute, Union Memorial Hospital, Baltimore, Maryland
1 shared publication
Latest Publications
- Open Access
Early Clinical Outcomes of a Nitrided Ti-6Al-4V Titanium Alloy Anatomic Total Knee Replacement System
Background/Objectives: To prevent potential complications for patients with metal hypersensitivity requiring total knee arthroplasty (TKA), implant coatings have been developed. Thermal nitriding of the titanium surface creates a TiN layer that increases hardness and wear resistance while preventing release of cobalt and chromium ions. The aim of this study was to evaluate the clinical safety and performance of an anatomic implant system comprised of thermally nitrided Ti-6Al-4V. Methods: This is an ongoing prospective, multicenter observational cohort study of primary and revision TKA patients. Patient-reported outcome measures including the Oxford Knee Score (OKS), Knee Society Score (KSS) Expectations subscale, EQ-5D-5L, physical exams, and radiographic assessments to document abnormalities were investigated in 94 patients who provided at least two years of follow-up data. The primary endpoint was improvement in the Oxford Knee Score (OKS), defined as the minimal clinically important difference (MCID, 7.0 points). Results: All outcome measures including patient-reported function (OKS) demonstrated significant improvements (19.4–22.6 points) exceeding the MCID with no between-group differences by bearing types utilized. Health-related quality of life as measured by EQ-5D-5L improved over the cohort and was maintained at 2-years post-operative. In total, three (1.4%) radiographic abnormalities were observed, all of which resolved at two-year follow-up. 12 (5.3%) serious complications were reported, none of which were related to the device. Two revisions have occurred, one due to infection and one due to a fall, in the ultracongruent bearing cohort (survivorship 98.1%, 95%CI 87.4–99.7). Implant survivorship was 100% in all other bearing cohorts. Conclusions: This anatomically designed, thermally nitrided titanium alloy implant demonstrated clinically significant improvements in function, PROMs, and quality of life in patients undergoing TKA regardless of bearing type. Excellent two-year implant survivorship between 98.1% and 100% across cohorts were observed, with no radiographic abnormalities at 2 years.
Open AccessEarly Clinical Outcomes of a Nitrided Ti-6Al-4V Titanium Alloy Anatomic Total Knee Replacement System
Background/Objectives: To prevent potential complications for patients with metal hypersensitivity requiring total knee arthroplasty (TKA), implant coatings have been developed. Thermal nitriding of the titanium surface creates a TiN layer that increases hardness and wear resistance while preventing release of cobalt and chromium ions. The aim of this study was to evaluate the clinical safety and performance of an anatomic implant system comprised of thermally nitrided Ti-6Al-4V. Methods: This is an ongoing prospective, multicenter observational cohort study of primary and revision TKA patients. Patient-reported outcome measures including the Oxford Knee Score (OKS), Knee Society Score (KSS) Expectations subscale, EQ-5D-5L, physical exams, and radiographic assessments to document abnormalities were investigated in 94 patients who provided at least two years of follow-up data. The primary endpoint was improvement in the Oxford Knee Score (OKS), defined as the minimal clinically important difference (MCID, 7.0 points). Results: All outcome measures including patient-reported function (OKS) demonstrated significant improvements (19.4–22.6 points) exceeding the MCID with no between-group differences by bearing types utilized. Health-related quality of life as measured by EQ-5D-5L improved over the cohort and was maintained at 2-years post-operative. In total, three (1.4%) radiographic abnormalities were observed, all of which resolved at two-year follow-up. 12 (5.3%) serious complications were reported, none of which were related to the device. Two revisions have occurred, one due to infection and one due to a fall, in the ultracongruent bearing cohort (survivorship 98.1%, 95%CI 87.4–99.7). Implant survivorship was 100% in all other bearing cohorts. Conclusions: This anatomically designed, thermally nitrided titanium alloy implant demonstrated clinically significant improvements in function, PROMs, and quality of life in patients undergoing TKA regardless of bearing type. Excellent two-year implant survivorship between 98.1% and 100% across cohorts were observed, with no radiographic abnormalities at 2 years.
- 25 September 2024
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 36 (1)
Comparing clinical and patient-reported outcomes between robot-assisted and conventional unicompartmental knee arthroplasty
Background: Robot-assisted (RA) unicompartmental knee arthroplasty (UKA) has been associated with improved implant alignment and accuracy compared to conventional UKA; however, it is unclear if this translates to improved outcomes. The aim of this study was to compare short-term clinical and functional outcomes between RA and conventional UKA. Methods: A retrospective review of primary UKAs performed by a single surgeon from 2002 to 2021 was conducted using the institution’s electronic health records and outcomes database. Outcomes included 90-day complications, cumulative revisions, implant survivorship, and patient-reported outcome measures (PROMs). Oxford Knee Scores (OKS) and SF-12 physical and mental were compared using a mixed-effect regression model. A Kaplan-Meier curve was plotted to illustrate survivorship using revision as the endpoint. Results: A total of 397 cases were included (RA: n=85; conventional: n=312). The RA group had significantly more men (P0.05). There was no difference in the rates of 90-day complications (RA: n=0, 0% vs. conventional: n=1, 0.9%, P=1). Significantly fewer cumulative revisions occurred in the RA group (RA: n=0, 0% vs. conventional: n=18, 5.8%; P=0.02). The median lengths of follow-up for RA and conventional UKA were 772 and 5,393 days, respectively. Both techniques showed within-group improvement in OKS and SF-12 physical through 2 yr (P<0.01). No between-group differences in PROMs occurred at any time point. Conclusions: Medial, fixed-bearing RA UKA shows no compromise in patient safety or outcomes when compared to conventional UKA through early-term follow-up.
- 25 September 2024
- Published by Wolters Kluwer Health in Current Orthopaedic Practice
- Vol. 36 (1)
Comparing clinical and patient-reported outcomes between robot-assisted and conventional unicompartmental knee arthroplasty
Background: Robot-assisted (RA) unicompartmental knee arthroplasty (UKA) has been associated with improved implant alignment and accuracy compared to conventional UKA; however, it is unclear if this translates to improved outcomes. The aim of this study was to compare short-term clinical and functional outcomes between RA and conventional UKA. Methods: A retrospective review of primary UKAs performed by a single surgeon from 2002 to 2021 was conducted using the institution’s electronic health records and outcomes database. Outcomes included 90-day complications, cumulative revisions, implant survivorship, and patient-reported outcome measures (PROMs). Oxford Knee Scores (OKS) and SF-12 physical and mental were compared using a mixed-effect regression model. A Kaplan-Meier curve was plotted to illustrate survivorship using revision as the endpoint. Results: A total of 397 cases were included (RA: n=85; conventional: n=312). The RA group had significantly more men (P0.05). There was no difference in the rates of 90-day complications (RA: n=0, 0% vs. conventional: n=1, 0.9%, P=1). Significantly fewer cumulative revisions occurred in the RA group (RA: n=0, 0% vs. conventional: n=18, 5.8%; P=0.02). The median lengths of follow-up for RA and conventional UKA were 772 and 5,393 days, respectively. Both techniques showed within-group improvement in OKS and SF-12 physical through 2 yr (P<0.01). No between-group differences in PROMs occurred at any time point. Conclusions: Medial, fixed-bearing RA UKA shows no compromise in patient safety or outcomes when compared to conventional UKA through early-term follow-up.
- Open Access
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 9 (1)
The Impact of Signaling on the 2022 to 2023 Orthopaedic Residency Application Cycle: A Survey of Incoming Residents
Background: During the 2022 to 2023 orthopaedic surgery residency application cycle, “signaling” was added, allowing applicants to communicate strong interest to 30 programs of their choosing. This study's purpose was to evaluate signaling's impact on the 2022 to 2023 application cycle. Methods: A cross-sectional survey was distributed to applicants who applied to a single residency program. We evaluated how many interviews the average applicant received, what proportion of interviews came from programs they had signaled, and what percentage of applicants matched at a program they had signaled. We stratified data by American Orthopaedic Association status, United States Medical Licensing Examination (USMLE) Step 1 and Step 2 scores, research items, sex, and race. Results: This survey was distributed to 611 applicants, with 124 (20.3%) responding to the survey. Ninety-five respondents (76.6%) matched. The percentage of applicant interviews that came from signaled programs was 78.7%. Ninety-one percent of matched applicants matched at a program they signaled. Sixty-three percent of matched applicants performed an away rotation at their matched programs. Forty-five percent of applicants felt that signaling incentivized reducing the programs they applied to, and applicants gave signaling a high favorability rating of 4/5. Applicants with Alpha Omega Alpha status received more interviews per application (0.18 ± 0.11 vs. 0.10 ± 0.10, p < 0.001) and more interviews from programs they did not signal (74% of interviews from signaled programs vs. 90% of interviews from signaled programs, p < 0.001). Higher Step 1 and Step 2 scores were associated with more interviews per application (Step 1: 0.16 ± 0.12 vs. 0.12 ± 0.08, p = 0.032) (Step 2: 0.16 ± 0.11 vs. 0.12 ± 0.09, p = 0.032). Conclusion: Orthopaedic residency applicants received most of their interviews from programs that they signaled, with an overwhelming majority matching at signaled program. Alpha Omega Alpha status and high USMLE scores were associated with more interviews granted per application, regardless of signaling status. Signaling seems to be a favorable option for orthopaedic applicants. Data from future application cycles will help further evaluate signaling's impact on the orthopaedic match.
- 1 January 2024
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 9 (1)
Open AccessThe Impact of Signaling on the 2022 to 2023 Orthopaedic Residency Application Cycle: A Survey of Incoming Residents
Background: During the 2022 to 2023 orthopaedic surgery residency application cycle, “signaling” was added, allowing applicants to communicate strong interest to 30 programs of their choosing. This study's purpose was to evaluate signaling's impact on the 2022 to 2023 application cycle. Methods: A cross-sectional survey was distributed to applicants who applied to a single residency program. We evaluated how many interviews the average applicant received, what proportion of interviews came from programs they had signaled, and what percentage of applicants matched at a program they had signaled. We stratified data by American Orthopaedic Association status, United States Medical Licensing Examination (USMLE) Step 1 and Step 2 scores, research items, sex, and race. Results: This survey was distributed to 611 applicants, with 124 (20.3%) responding to the survey. Ninety-five respondents (76.6%) matched. The percentage of applicant interviews that came from signaled programs was 78.7%. Ninety-one percent of matched applicants matched at a program they signaled. Sixty-three percent of matched applicants performed an away rotation at their matched programs. Forty-five percent of applicants felt that signaling incentivized reducing the programs they applied to, and applicants gave signaling a high favorability rating of 4/5. Applicants with Alpha Omega Alpha status received more interviews per application (0.18 ± 0.11 vs. 0.10 ± 0.10, p < 0.001) and more interviews from programs they did not signal (74% of interviews from signaled programs vs. 90% of interviews from signaled programs, p < 0.001). Higher Step 1 and Step 2 scores were associated with more interviews per application (Step 1: 0.16 ± 0.12 vs. 0.12 ± 0.08, p = 0.032) (Step 2: 0.16 ± 0.11 vs. 0.12 ± 0.09, p = 0.032). Conclusion: Orthopaedic residency applicants received most of their interviews from programs that they signaled, with an overwhelming majority matching at signaled program. Alpha Omega Alpha status and high USMLE scores were associated with more interviews granted per application, regardless of signaling status. Signaling seems to be a favorable option for orthopaedic applicants. Data from future application cycles will help further evaluate signaling's impact on the orthopaedic match.
- Open Access
- 25 October 2022
- Published by Springer Nature in Cureus
- Vol. 14 (10) , e30667
Short-Term Outcomes Following Cemented Versus Cementless Robotic-Assisted Total Knee Arthroplasty
Background: Cemented fixation during total knee arthroplasty (TKA) has long been the gold standard due to excellent survivorship and clinical outcomes. With recent biomaterial advancements, cementless fixation has gained renewed interest. Most studies demonstrate similar clinical outcomes and survivorship between these two fixation methods, without consensus regarding the optimal method of fixation during TKA. Outcomes following TKA also depend upon the proper alignment and positioning of components. Robotic-assisted TKA has been shown to improve outcomes related to component positioning, overall lower limb alignment, and soft tissue balancing. No study to date has investigated the role of robotic-assisted surgery on postoperative outcomes following cementless versus cemented TKA. Methods: This is a retrospective cohort study of patients 18 years of age and older who underwent primary robotic-assisted TKA performed by a single fellowship-trained arthroplasty surgeon. Oxford Knee Scores and Short Form Health Survey scores were obtained preoperatively and at a two-year follow-up. Complications such as DVT, infection, arthrofibrosis requiring manipulation, and revision surgery were collected. Results: Three hundred eighty knees in the cementless cohort and 72 cemented knees were included for analysis. There were no statistically significant differences between the two cohorts in terms of SF-12, Oxford Knee Scores, complications, or revision surgery rates. Conclusion: Cementless fixation during TKA offers an alternative to cemented fixation with similar short-term results in terms of patient-reported outcomes, complication rates, and revision surgery rates. Further research is warranted to better understand long-term outcomes and survivorship following cementless versus cemented fixation during robotic-assisted TKA.
- 25 October 2022
- Published by Springer Nature in Cureus
- Vol. 14 (10) , e30667
Open AccessShort-Term Outcomes Following Cemented Versus Cementless Robotic-Assisted Total Knee Arthroplasty
Background: Cemented fixation during total knee arthroplasty (TKA) has long been the gold standard due to excellent survivorship and clinical outcomes. With recent biomaterial advancements, cementless fixation has gained renewed interest. Most studies demonstrate similar clinical outcomes and survivorship between these two fixation methods, without consensus regarding the optimal method of fixation during TKA. Outcomes following TKA also depend upon the proper alignment and positioning of components. Robotic-assisted TKA has been shown to improve outcomes related to component positioning, overall lower limb alignment, and soft tissue balancing. No study to date has investigated the role of robotic-assisted surgery on postoperative outcomes following cementless versus cemented TKA. Methods: This is a retrospective cohort study of patients 18 years of age and older who underwent primary robotic-assisted TKA performed by a single fellowship-trained arthroplasty surgeon. Oxford Knee Scores and Short Form Health Survey scores were obtained preoperatively and at a two-year follow-up. Complications such as DVT, infection, arthrofibrosis requiring manipulation, and revision surgery were collected. Results: Three hundred eighty knees in the cementless cohort and 72 cemented knees were included for analysis. There were no statistically significant differences between the two cohorts in terms of SF-12, Oxford Knee Scores, complications, or revision surgery rates. Conclusion: Cementless fixation during TKA offers an alternative to cemented fixation with similar short-term results in terms of patient-reported outcomes, complication rates, and revision surgery rates. Further research is warranted to better understand long-term outcomes and survivorship following cementless versus cemented fixation during robotic-assisted TKA.