Cong Pu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cong Pu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ben Fu
School of Biomedical Engineering, ShanghaiTech University, Shanghai, China
4 shared publications - Chang Peng
School of Biomedical Engineering and the State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, China
4 shared publications - Hui-Xiong Xu
Department of Ultrasound, Institute of Ultrasound in Medicine and Engineering, Zhongshan Hospital, Fudan University, Shanghai, China
3 shared publications - Le-Hang Guo
Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Shanghai, China
2 shared publications - Caixia Jia
Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Dandan Shan
Department of Medical Ultrasound, Shanghai Tenth People’s Hospital, School of Medicine, Tongji University, China
1 shared publication
Latest Publications
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Enhanced Mild Hyperthermia Using Focused Ultra-Sound and Microbubbles: An Experimental Study
Traditional cancer treatments like chemotherapy often involve systemic drug injection, affecting healthy tissues and causing unwanted side effects. Focused ultrasound (FUS), with its precise targeting capability, offers a solution by raising the temperature of cancer tissue to 39-45°C. This mild hyperthermia enhances tumor blood flow and improves chemotherapy drug absorption by cancer cells. To optimize this promising approach, a comprehensive understanding of the effects of microbubble-enhanced FUS is crucial. In this study, for the first time, we extensively examined the impact of various FUS parameters—such as frequency, duty cycle, and input voltage—alongside microbubble concentrations on temperature variations. Our goal was to identify optimal conditions for mild hyperthermia applications. The results revealed that increasing ultrasound frequency, duty cycle, driving voltage, and microbubble concentration enhances heating rates and peak temperatures. Microbubble concentrations of 104 MBs/mL showed minimal effect, but at 108 MBs/mL, significant temperature increases were observed, particularly at higher frequencies. To further understand the heating mechanism, we used a hydrophone to monitor acoustic signals during the process. The presence of microbubbles generated substantial broadband noise, indicating that inertial cavitation was a key factor in heating during FUS exposure. The noise signal’s power spectrum demonstrated that a higher duty cycle increased energy intensity, accelerating the heating rate. This study provides critical insights for adjusting ultrasound parameters and microbubble concentrations in clinical mild hyperthermia treatments, potentially enhancing the effectiveness of chemotherapy while minimizing side effects on healthy tissues.
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Enhanced Mild Hyperthermia Using Focused Ultra-Sound and Microbubbles: An Experimental Study
Traditional cancer treatments like chemotherapy often involve systemic drug injection, affecting healthy tissues and causing unwanted side effects. Focused ultrasound (FUS), with its precise targeting capability, offers a solution by raising the temperature of cancer tissue to 39-45°C. This mild hyperthermia enhances tumor blood flow and improves chemotherapy drug absorption by cancer cells. To optimize this promising approach, a comprehensive understanding of the effects of microbubble-enhanced FUS is crucial. In this study, for the first time, we extensively examined the impact of various FUS parameters—such as frequency, duty cycle, and input voltage—alongside microbubble concentrations on temperature variations. Our goal was to identify optimal conditions for mild hyperthermia applications. The results revealed that increasing ultrasound frequency, duty cycle, driving voltage, and microbubble concentration enhances heating rates and peak temperatures. Microbubble concentrations of 104 MBs/mL showed minimal effect, but at 108 MBs/mL, significant temperature increases were observed, particularly at higher frequencies. To further understand the heating mechanism, we used a hydrophone to monitor acoustic signals during the process. The presence of microbubbles generated substantial broadband noise, indicating that inertial cavitation was a key factor in heating during FUS exposure. The noise signal’s power spectrum demonstrated that a higher duty cycle increased energy intensity, accelerating the heating rate. This study provides critical insights for adjusting ultrasound parameters and microbubble concentrations in clinical mild hyperthermia treatments, potentially enhancing the effectiveness of chemotherapy while minimizing side effects on healthy tissues.
- Open Access
A Wearable Spiral Ultrasound Patch for Focused Ultrasound Peripheral Neuromodulation of Diabetic Neuropathic Pain
Diabetic foot disease, a severe complication of diabetes, frequently results in diabetic neuropathic pain, which diminishes quality of life and increases the risk of amputation. Current treatment options are limited in their effectiveness and can present adverse effects. We have demonstrated a first-of-its-kind wearable spiral ultrasound patch for focused ultrasound peripheral neuromodulation to alleviate diabetic neuropathic pain. This innovative, stretchable ultrasound device reliably delivers focused ultrasound to peripheral nerves. The device’s ultrasound elements are arranged in a phyllotaxis spiral pattern, enhancing transmitted acoustic focus performance and minimizing grating and side lobes. Using a diabetic foot rat model, we confirmed peripheral neuropathy through behavioral assessments of mechanical allodynia and heat hyperalgesia, which showed significant pain relief after two weeks of ultrasound treatment. Additionally, nerve conduction velocity improved. Biological safety tests indicated no adverse effects on nerve tissues or cells. Our approach offers a non-invasive solution for managing diabetic neuropathic pain and provides critical insights into its underlying mechanisms, paving the way for more effective therapies.
Open AccessA Wearable Spiral Ultrasound Patch for Focused Ultrasound Peripheral Neuromodulation of Diabetic Neuropathic Pain
Diabetic foot disease, a severe complication of diabetes, frequently results in diabetic neuropathic pain, which diminishes quality of life and increases the risk of amputation. Current treatment options are limited in their effectiveness and can present adverse effects. We have demonstrated a first-of-its-kind wearable spiral ultrasound patch for focused ultrasound peripheral neuromodulation to alleviate diabetic neuropathic pain. This innovative, stretchable ultrasound device reliably delivers focused ultrasound to peripheral nerves. The device’s ultrasound elements are arranged in a phyllotaxis spiral pattern, enhancing transmitted acoustic focus performance and minimizing grating and side lobes. Using a diabetic foot rat model, we confirmed peripheral neuropathy through behavioral assessments of mechanical allodynia and heat hyperalgesia, which showed significant pain relief after two weeks of ultrasound treatment. Additionally, nerve conduction velocity improved. Biological safety tests indicated no adverse effects on nerve tissues or cells. Our approach offers a non-invasive solution for managing diabetic neuropathic pain and provides critical insights into its underlying mechanisms, paving the way for more effective therapies.
- 4 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15875-15883
A Stretchable and Wearable Ultrasonic Transducer Array for Bladder Volume Monitoring Application
Monitoring bladder volume is an essential application for patients with voiding dysfunction. Current wearable ultrasonic bladder monitors are rigid, bulky and cannot conform to human skin. This study presents a stretchable and wearable ultrasonic transducer array that can both conform to non-planar skin surfaces and continuously monitor bladder volume. The wearable transducer array mainly consists of 4 × 4 piezoelectric transducer elements, stretchable serpentine-based electrodes for electrical interconnection, electrically conductive adhesive as both matching and backing layers, and silicone elastomer for encapsulation. The transducer array has a center frequency of 3.9 MHz, -6 dB acoustic bandwidth of 57.6%, and up to 40% elastic stretchability. The volume of balloon-bladder phantom was estimated by a least square ellipsoid fitting method. With the true volume of balloon-bladder phantoms ranging from 10 mL to 405 mL, the proposed transducer array has a mean absolute percentage error of 9.4%, a mean absolute error of 11.9 mL and a coefficient of determination of 0.975, which demonstrates the capability of the proposed stretchable and wearable ultrasonic transducer array for bladder volume monitoring application.
- 4 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (10) , 15875-15883
A Stretchable and Wearable Ultrasonic Transducer Array for Bladder Volume Monitoring Application
Monitoring bladder volume is an essential application for patients with voiding dysfunction. Current wearable ultrasonic bladder monitors are rigid, bulky and cannot conform to human skin. This study presents a stretchable and wearable ultrasonic transducer array that can both conform to non-planar skin surfaces and continuously monitor bladder volume. The wearable transducer array mainly consists of 4 × 4 piezoelectric transducer elements, stretchable serpentine-based electrodes for electrical interconnection, electrically conductive adhesive as both matching and backing layers, and silicone elastomer for encapsulation. The transducer array has a center frequency of 3.9 MHz, -6 dB acoustic bandwidth of 57.6%, and up to 40% elastic stretchability. The volume of balloon-bladder phantom was estimated by a least square ellipsoid fitting method. With the true volume of balloon-bladder phantoms ranging from 10 mL to 405 mL, the proposed transducer array has a mean absolute percentage error of 9.4%, a mean absolute error of 11.9 mL and a coefficient of determination of 0.975, which demonstrates the capability of the proposed stretchable and wearable ultrasonic transducer array for bladder volume monitoring application.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Systematic Investigation of Thermal Effects of High-Intensity Focused Ultrasound Therapy for Ultrasound Neuromodulation
Ultrasound neuromodulation has demonstrated potentials for non-invasively activating ion channels within cell membranes and regulating neuronal activities in animal models and humans. The thermal effects of focused ultrasound play a significant role in activating the thermosensitive ion channels. However, until now the effects of various focused ultrasound parameters on the resultant temperature distribution for activating thermosensitive ion channels have not yet been sufficiently elucidated. In this study, in-vitro experiments are conducted by using high-intensity focused ultrasound transducers in three different types of porcine tissues including pork, liver and brain tissues. The influences of different ultrasound parameters on thermal effects are systematically analyzed. Our results show that elevating the ultrasound parameters including ultrasound frequency, acoustic power, and duty cycle can directly increase temperature rising rates and peak temperature values, while varying the pulse cycle number from 10 to 20 has nearly no impact. Furthermore, higher-frequency ultrasound stimulation such as 1.59 MHz and 2 MHz exhibits a larger temperature difference in the vicinity of the focal region. Our results also reveal that the temperature rising rate varies in that three types of tissues, which is dominant by the distinct acoustic attenuation coefficients. The findings in this study provide valuable insights for designing an effective ultrasound thermal neuromodulation sequence for clinical applications.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Systematic Investigation of Thermal Effects of High-Intensity Focused Ultrasound Therapy for Ultrasound Neuromodulation
Ultrasound neuromodulation has demonstrated potentials for non-invasively activating ion channels within cell membranes and regulating neuronal activities in animal models and humans. The thermal effects of focused ultrasound play a significant role in activating the thermosensitive ion channels. However, until now the effects of various focused ultrasound parameters on the resultant temperature distribution for activating thermosensitive ion channels have not yet been sufficiently elucidated. In this study, in-vitro experiments are conducted by using high-intensity focused ultrasound transducers in three different types of porcine tissues including pork, liver and brain tissues. The influences of different ultrasound parameters on thermal effects are systematically analyzed. Our results show that elevating the ultrasound parameters including ultrasound frequency, acoustic power, and duty cycle can directly increase temperature rising rates and peak temperature values, while varying the pulse cycle number from 10 to 20 has nearly no impact. Furthermore, higher-frequency ultrasound stimulation such as 1.59 MHz and 2 MHz exhibits a larger temperature difference in the vicinity of the focal region. Our results also reveal that the temperature rising rate varies in that three types of tissues, which is dominant by the distinct acoustic attenuation coefficients. The findings in this study provide valuable insights for designing an effective ultrasound thermal neuromodulation sequence for clinical applications.