Jingya Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingya Duan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Le Xuan
College of Landscape Architecture & Arts, Northwest A&F University, Yangling, China
3 shared publications - Tianji Wu
College of Landscape Architecture & Arts, Northwest A&F University, Yangling, China
3 shared publications - Xuhui Wang
Institute of Carbon Neutrality, Sino-French Institute for Earth System Science, College of Urban and Environmental Sciences, Peking University , Beijing 100871
3 shared publications - Yutong Su
College of Landscape Architecture and Arts, Northwest A&F University, Yangling, Xianyang 712100, China
3 shared publications - Chao Wang
Xi’an High-Tech Zone Natural Resources and Planning Bureau, Xi’an 710117, China
1 shared publication - Chunlei Du
School of Human Settlements and Civil Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
How to Plan Urban Parks and the Surrounding Buildings to Maximize the Cooling Effect: A Case Study in Xi’an, China
Urban areas with parks tend to have the best outdoor thermal comfort in regions with high urban heat island effects during summer. This study analyzed the synergistic cooling effects of 94 urban parks and the adjacent built-up areas in six districts of Xi’an City using four cooling indicators: park cooling intensity (PCI), park cooling area (PCA), park cooling effect (PCE), and park cooling gradient (PCG). The results showed that 84 out of 94 parks exhibited significant cooling effects, with an average PCI of 1.98 °C, PCA of 51.7 ha, PCE of 6.6, and PCG of 8.2 °C/km. Correlation analyses indicated that the intrinsic park attributes, external buffer zone building height, and building density were the main factors affecting the cooling effect. The park landscape configuration, building height, and density significantly influenced the PCI and PCG, while the park shape and size were crucial for the PCA (positive) and PCE (negative). The optimal park areas for improving the thermal environment were identified as 26 ha (cooling area focus, building density <13%) and 15 ha (cooling intensity focus, building height 32%). This study provides theoretical guidance for planning urban parks and the surrounding areas based on cooling effects, offering insights for future climate resilience planning.
Open AccessHow to Plan Urban Parks and the Surrounding Buildings to Maximize the Cooling Effect: A Case Study in Xi’an, China
Urban areas with parks tend to have the best outdoor thermal comfort in regions with high urban heat island effects during summer. This study analyzed the synergistic cooling effects of 94 urban parks and the adjacent built-up areas in six districts of Xi’an City using four cooling indicators: park cooling intensity (PCI), park cooling area (PCA), park cooling effect (PCE), and park cooling gradient (PCG). The results showed that 84 out of 94 parks exhibited significant cooling effects, with an average PCI of 1.98 °C, PCA of 51.7 ha, PCE of 6.6, and PCG of 8.2 °C/km. Correlation analyses indicated that the intrinsic park attributes, external buffer zone building height, and building density were the main factors affecting the cooling effect. The park landscape configuration, building height, and density significantly influenced the PCI and PCG, while the park shape and size were crucial for the PCA (positive) and PCE (negative). The optimal park areas for improving the thermal environment were identified as 26 ha (cooling area focus, building density <13%) and 15 ha (cooling intensity focus, building height 32%). This study provides theoretical guidance for planning urban parks and the surrounding areas based on cooling effects, offering insights for future climate resilience planning.
- Open Access
- 16 February 2024
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 68 (5) , 909-925
Analysis of the correlation mechanism between geometric parameters and the thermal environment of Xi’an’s summer outdoor commercial pedestrian streets
Intensive urban development has resulted in the degradation of the urban thermal environment in most regions. There is a growing consensus on the need to enhance urban thermal comfort through well-designed forms, especially in open spaces like urban canyons. To address this, our study focuses on Xi’an’s commercial pedestrian streets, employing K-means clustering analysis to create 32 representative models based on actual scenes, capturing their textural characteristics. Simultaneously, 11 geometric indicators (2D/3D) were chosen to quantify the canyon’s geometric form. We assessed the spatial and temporal distribution differences in the thermal environment across these models using Envi-met simulation. Finally, Spearman correlation analysis was employed to examine the correlation and significance of the two sets of indicators, culminating in formulating an ideal model. The findings reveal that (1) wind conditions are predominantly influenced by the canyon’s geometric form, followed by solar radiation and temperature, with the lowest relative humidity change amplitude among the assessed thermal parameters. (2) Among the 11 geometric form indicators, 3D indicators correlate more significantly with thermal environment parameters than 2D indicators. Specifically, street orientation significantly impacts the thermal environment, Build-To-Line Rat holds greater significance than interface density, and both building shape coefficient and block surface ratio are significantly correlated with air temperature and wind speed, with a weaker correlation to solar radiation. (3) In the Xi’an region, courtyards oriented north-south demonstrate a more favorable trend in the thermal environment.
- 16 February 2024
- Published by Springer Nature in International Journal of Biometeorology
- Vol. 68 (5) , 909-925
Open AccessAnalysis of the correlation mechanism between geometric parameters and the thermal environment of Xi’an’s summer outdoor commercial pedestrian streets
Intensive urban development has resulted in the degradation of the urban thermal environment in most regions. There is a growing consensus on the need to enhance urban thermal comfort through well-designed forms, especially in open spaces like urban canyons. To address this, our study focuses on Xi’an’s commercial pedestrian streets, employing K-means clustering analysis to create 32 representative models based on actual scenes, capturing their textural characteristics. Simultaneously, 11 geometric indicators (2D/3D) were chosen to quantify the canyon’s geometric form. We assessed the spatial and temporal distribution differences in the thermal environment across these models using Envi-met simulation. Finally, Spearman correlation analysis was employed to examine the correlation and significance of the two sets of indicators, culminating in formulating an ideal model. The findings reveal that (1) wind conditions are predominantly influenced by the canyon’s geometric form, followed by solar radiation and temperature, with the lowest relative humidity change amplitude among the assessed thermal parameters. (2) Among the 11 geometric form indicators, 3D indicators correlate more significantly with thermal environment parameters than 2D indicators. Specifically, street orientation significantly impacts the thermal environment, Build-To-Line Rat holds greater significance than interface density, and both building shape coefficient and block surface ratio are significantly correlated with air temperature and wind speed, with a weaker correlation to solar radiation. (3) In the Xi’an region, courtyards oriented north-south demonstrate a more favorable trend in the thermal environment.
- Open Access
- 25 October 2023
- Published by Springer Nature in Research Square
Analysis and Ideal Model Construction of the Geometric Parameters and Thermal Environment Correlation Mechanism of Xi'an's Summer Outdoor Commercial Pedestrian Streets
Intensive urban development has resulted in the degradation of the urban thermal environment. There is a growing consensus on the need to enhance urban thermal comfort through well-designed forms, especially in open spaces like urban canyons. To address this, our study focuses on Xi'an's commercial pedestrian streets, employing K-means clustering analysis to create 32 representative models based on actual scenes, capturing their textural characteristics. Simultaneously, 11 geometric indicators (2D/3D) were chosen to quantify the canyon's geometric form. We assessed the spatial and temporal distribution differences in the thermal environment across these models using Envi-met simulation. Finally, Spearman correlation analysis was employed to examine the correlation and significance of the two sets of indicators, culminating in formulating an ideal model. The findings reveal that (1) wind conditions are predominantly influenced by the canyon's geometric form, followed by solar radiation and temperature, with the lowest relative humidity change amplitude among the assessed thermal parameters. (2) Among the 11 geometric form indicators, 3D indicators correlate more significantly with thermal environment parameters than 2D indicators. Specifically, SO significantly impacts the thermal environment, P holds greater significance than De, and both BSC and BSR are significantly correlated with air temperature and wind speed, with a weaker correlation to solar radiation. (3) In the Xi'an region, courtyards oriented north-south demonstrate a more favorable trend in the thermal environment.
- 25 October 2023
- Published by Springer Nature in Research Square
Open AccessAnalysis and Ideal Model Construction of the Geometric Parameters and Thermal Environment Correlation Mechanism of Xi'an's Summer Outdoor Commercial Pedestrian Streets
Intensive urban development has resulted in the degradation of the urban thermal environment. There is a growing consensus on the need to enhance urban thermal comfort through well-designed forms, especially in open spaces like urban canyons. To address this, our study focuses on Xi'an's commercial pedestrian streets, employing K-means clustering analysis to create 32 representative models based on actual scenes, capturing their textural characteristics. Simultaneously, 11 geometric indicators (2D/3D) were chosen to quantify the canyon's geometric form. We assessed the spatial and temporal distribution differences in the thermal environment across these models using Envi-met simulation. Finally, Spearman correlation analysis was employed to examine the correlation and significance of the two sets of indicators, culminating in formulating an ideal model. The findings reveal that (1) wind conditions are predominantly influenced by the canyon's geometric form, followed by solar radiation and temperature, with the lowest relative humidity change amplitude among the assessed thermal parameters. (2) Among the 11 geometric form indicators, 3D indicators correlate more significantly with thermal environment parameters than 2D indicators. Specifically, SO significantly impacts the thermal environment, P holds greater significance than De, and both BSC and BSR are significantly correlated with air temperature and wind speed, with a weaker correlation to solar radiation. (3) In the Xi'an region, courtyards oriented north-south demonstrate a more favorable trend in the thermal environment.