Mikio Shiozawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mikio Shiozawa has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Miki
Department of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, Shimotsuke, Japan
2 shared publications Hiroshi Kawahira
Department of Surgery, Division of Gastroenterological, General, and Transplant Surgery, Jichi Medical University, Shimotsuke city, Japan
2 shared publicationsHiroyuki Kitabayashi
Department of Surgery, Tochigi Medical Center, Tochigi, Tochigi, Japan
2 shared publicationsMakiko Tahara
Department of Surgery, Tochigi Medical Center, Tochigi, Tochigi, Japan
2 shared publicationsMasako Sakuragi
2 shared publications- Masaru Koizumi
Department of Surgery, Tochigi Medical Center Shimotsuga, Tochigi, Tochigi, Japan
2 shared publications
Latest Publications
- 29 August 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83 (11)
Subjective and HRV-based Data Assessing Supervising Surgeon Intraoperative Stress with Perceived Trainee Breast Surgery Skill Proficiency
- 29 August 2026
- Published by Elsevier in Journal of Surgical Education
- Vol. 83 (11)
Subjective and HRV-based Data Assessing Supervising Surgeon Intraoperative Stress with Perceived Trainee Breast Surgery Skill Proficiency
- Open Access
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0323
Laparoscopic Intraperitoneal Onlay Mesh Plus Repair of a Hernia Adjacent to a Vesicocutaneous Urinary Diversion: A Case Report
INTRODUCTION: Hernias occurring adjacent to a urinary diversion are extremely rare, and their classification and optimal surgical management have not yet been established.CASE PRESENTATION: A 76-year-old man presented with a hernia adjacent to a vesicocutaneous urinary diversion after undergoing laparoscopic abdominoperineal resection for rectal cancer combined with robot-assisted radical prostatectomy, resulting in sigmoid colostomy and vesicocutaneous fistula formation. Laparoscopic repair was performed using the intraperitoneal onlay mesh (IPOM) plus technique. After primary fascial closure, a trimmed composite mesh was placed with adequate overlap and fixed using a modified fixation strategy combining non-absorbable tacks and absorbable sutures. Tacking was deliberately avoided in the anatomically hazardous region adjacent to the external iliac vessels, and fixation in this area was achieved using superficial sutures only. The postoperative course was uneventful, with no recurrence or mesh-related complications during the 18-month follow-up.CONCLUSION: Laparoscopic IPOM plus repair may be a feasible option for hernias adjacent to a vesicocutaneous urinary diversion when primary fascial closure and safe mesh fixation can be achieved with careful consideration of pelvic anatomy and adjacent neurovascular structures. However, further accumulation of cases and long-term follow-up are required to establish its safety.
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0323
Open AccessLaparoscopic Intraperitoneal Onlay Mesh Plus Repair of a Hernia Adjacent to a Vesicocutaneous Urinary Diversion: A Case Report
INTRODUCTION: Hernias occurring adjacent to a urinary diversion are extremely rare, and their classification and optimal surgical management have not yet been established.CASE PRESENTATION: A 76-year-old man presented with a hernia adjacent to a vesicocutaneous urinary diversion after undergoing laparoscopic abdominoperineal resection for rectal cancer combined with robot-assisted radical prostatectomy, resulting in sigmoid colostomy and vesicocutaneous fistula formation. Laparoscopic repair was performed using the intraperitoneal onlay mesh (IPOM) plus technique. After primary fascial closure, a trimmed composite mesh was placed with adequate overlap and fixed using a modified fixation strategy combining non-absorbable tacks and absorbable sutures. Tacking was deliberately avoided in the anatomically hazardous region adjacent to the external iliac vessels, and fixation in this area was achieved using superficial sutures only. The postoperative course was uneventful, with no recurrence or mesh-related complications during the 18-month follow-up.CONCLUSION: Laparoscopic IPOM plus repair may be a feasible option for hernias adjacent to a vesicocutaneous urinary diversion when primary fascial closure and safe mesh fixation can be achieved with careful consideration of pelvic anatomy and adjacent neurovascular structures. However, further accumulation of cases and long-term follow-up are required to establish its safety.
- Open Access
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0017
A Rare Case of Small Bowel Volvulus with Chylous Ascites Presumed to Be Caused by Multiple Congenital Adhesions in a Virgin Abdomen: A Case Report and Literature Review
INTRODUCTION: Chylous ascites is an uncommon condition resulting from triglyceride-rich lymphatic fluid leakage into the peritoneal cavity and is typically diagnosed when the ascitic triglyceride level is ≥200 mg/dL. Small bowel volvulus is an uncommon surgical emergency, and its coexistence with chylous ascites is particularly rare. Postoperative adhesions are a common cause of small bowel volvulus; however, small bowel volvulus caused by adhesions presumed to be congenital in a virgin abdomen is infrequently reported. Herein, we report a case of small bowel volvulus associated with chylous ascites in which the adhesions were most consistent with congenital origin, although definitive differentiation was not possible.CASE PRESENTATION: A 61-year-old male with no history of abdominal surgery presented with sudden-onset abdominal pain. Contrast-enhanced CT revealed a whirl sign in the mesentery with mild ascites. Emergency exploratory laparotomy revealed milky-white ascites and 360° volvulus at the root of the small bowel mesentery. Multiple adhesions, presumed to be congenital based on the absence of prior surgery or documented inflammation, were identified as the underlying cause of the volvulus. All adhesions were carefully divided; de-torsion alone was sufficient, and bowel resection was unnecessary. Biochemical analysis of the ascitic fluid revealed a triglyceride level of 200 mg/dL, which confirmed the diagnosis of chylous ascites. The patient recovered uneventfully and remained recurrence-free for 6 months.CONCLUSIONS: This report describes a rare case of small bowel volvulus accompanied by chylous ascites presumed to be caused by multiple congenital adhesions in a virgin abdomen. Although causal relationships cannot be definitively established, this case highlights important considerations regarding intraoperative assessment of bowel viability and adhesions. The presence of chylous ascites alone should not be regarded as a reliable indicator of bowel ischemia; careful surgical evaluation remains essential.
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0017
Open AccessA Rare Case of Small Bowel Volvulus with Chylous Ascites Presumed to Be Caused by Multiple Congenital Adhesions in a Virgin Abdomen: A Case Report and Literature Review
INTRODUCTION: Chylous ascites is an uncommon condition resulting from triglyceride-rich lymphatic fluid leakage into the peritoneal cavity and is typically diagnosed when the ascitic triglyceride level is ≥200 mg/dL. Small bowel volvulus is an uncommon surgical emergency, and its coexistence with chylous ascites is particularly rare. Postoperative adhesions are a common cause of small bowel volvulus; however, small bowel volvulus caused by adhesions presumed to be congenital in a virgin abdomen is infrequently reported. Herein, we report a case of small bowel volvulus associated with chylous ascites in which the adhesions were most consistent with congenital origin, although definitive differentiation was not possible.CASE PRESENTATION: A 61-year-old male with no history of abdominal surgery presented with sudden-onset abdominal pain. Contrast-enhanced CT revealed a whirl sign in the mesentery with mild ascites. Emergency exploratory laparotomy revealed milky-white ascites and 360° volvulus at the root of the small bowel mesentery. Multiple adhesions, presumed to be congenital based on the absence of prior surgery or documented inflammation, were identified as the underlying cause of the volvulus. All adhesions were carefully divided; de-torsion alone was sufficient, and bowel resection was unnecessary. Biochemical analysis of the ascitic fluid revealed a triglyceride level of 200 mg/dL, which confirmed the diagnosis of chylous ascites. The patient recovered uneventfully and remained recurrence-free for 6 months.CONCLUSIONS: This report describes a rare case of small bowel volvulus accompanied by chylous ascites presumed to be caused by multiple congenital adhesions in a virgin abdomen. Although causal relationships cannot be definitively established, this case highlights important considerations regarding intraoperative assessment of bowel viability and adhesions. The presence of chylous ascites alone should not be regarded as a reliable indicator of bowel ischemia; careful surgical evaluation remains essential.
- 16 December 2025
- Published by Springer Nature in Journal of Cancer Education
- p. 1-8
Development and Evaluation of A PC-Compatible E-Learning System for Mammography and Breast Ultrasound
- 16 December 2025
- Published by Springer Nature in Journal of Cancer Education
- p. 1-8
Development and Evaluation of A PC-Compatible E-Learning System for Mammography and Breast Ultrasound
- Open Access
- 16 January 2024
- Published by Springer Nature in Cureus
- Vol. 16 (1) , e52402
Evaluation of Scissor Glide Characteristics Through Surgeons' Subjective Assessment: The Application of Nitriding in Scissor Hardening Tests
Introduction: In robotic surgery, studies on providing tactile feedback to users are ongoing. However, the accuracy of the subjective sensations of surgeons, as users, has been largely unassessed. This study aimed to assess the validity of surgeons' subjective evaluations of scissors resistance through interindividual, intersurgeon, and objective evaluations. Furthermore, in this study, we explored the possibility of using nitriding to increase the hardness of the scissors and assessed changes in subjective resistance values before and after nitriding using this approach. Method: Five surgeons conducted validation of five curved surgical scissors (145 mm; Arakawa Seisakujyo Co., Ltd., Tokyo, Japan) and assessed their subjective resistance using a scale from 0 to 10, where a rating of 10 signified significant resistance impeding the scissors' closure. The temporal changes in subjective resistance values, from maximum open to close, were graphically recorded. To demonstrate the reproducibility of subjective resistance values, the subjective resistance values of the same control scissors were measured at intervals of at least two weeks, and the correlation coefficient was calculated. To analyze the closing characteristics of subjective resistance values between different pairs of scissors, the effect of scissor type and scissor closure position was compared as two independent variables using a two -factor analysis of variance. A comparative evaluation was conducted to assess the frictional properties of scissors after nitriding, comparing the subjective assessment by surgeons with the objective assessment using a digital force gauge. Results: The correlation coefficient of subjective resistance values measured by surgeons demonstrated a high reproducibility of 0.746. A two -factor analysis of variance conducted on subjective resistance values demonstrated the presence of a primary effect for the sample factor (scissors), as well as for the position factor (closing process), with the additional observation of the interaction between these two factors. The results from the two -factor analysis of variance above provide evidence supporting the validity of the subjective resistance measurements. There was a significant increase in subjective resistance after the nitriding process. The graph of subjective resistance values and objective resistance values showed similarity. Conclusions: The surgeons' subjective assessment of scissors resistance showed high reproducibility and validity, as evidenced by distinguishable differences in scissor movement interactions and pre- and postnitriding resistance. Further studies are warranted to expand on these findings.
- 16 January 2024
- Published by Springer Nature in Cureus
- Vol. 16 (1) , e52402
Open AccessEvaluation of Scissor Glide Characteristics Through Surgeons' Subjective Assessment: The Application of Nitriding in Scissor Hardening Tests
Introduction: In robotic surgery, studies on providing tactile feedback to users are ongoing. However, the accuracy of the subjective sensations of surgeons, as users, has been largely unassessed. This study aimed to assess the validity of surgeons' subjective evaluations of scissors resistance through interindividual, intersurgeon, and objective evaluations. Furthermore, in this study, we explored the possibility of using nitriding to increase the hardness of the scissors and assessed changes in subjective resistance values before and after nitriding using this approach. Method: Five surgeons conducted validation of five curved surgical scissors (145 mm; Arakawa Seisakujyo Co., Ltd., Tokyo, Japan) and assessed their subjective resistance using a scale from 0 to 10, where a rating of 10 signified significant resistance impeding the scissors' closure. The temporal changes in subjective resistance values, from maximum open to close, were graphically recorded. To demonstrate the reproducibility of subjective resistance values, the subjective resistance values of the same control scissors were measured at intervals of at least two weeks, and the correlation coefficient was calculated. To analyze the closing characteristics of subjective resistance values between different pairs of scissors, the effect of scissor type and scissor closure position was compared as two independent variables using a two -factor analysis of variance. A comparative evaluation was conducted to assess the frictional properties of scissors after nitriding, comparing the subjective assessment by surgeons with the objective assessment using a digital force gauge. Results: The correlation coefficient of subjective resistance values measured by surgeons demonstrated a high reproducibility of 0.746. A two -factor analysis of variance conducted on subjective resistance values demonstrated the presence of a primary effect for the sample factor (scissors), as well as for the position factor (closing process), with the additional observation of the interaction between these two factors. The results from the two -factor analysis of variance above provide evidence supporting the validity of the subjective resistance measurements. There was a significant increase in subjective resistance after the nitriding process. The graph of subjective resistance values and objective resistance values showed similarity. Conclusions: The surgeons' subjective assessment of scissors resistance showed high reproducibility and validity, as evidenced by distinguishable differences in scissor movement interactions and pre- and postnitriding resistance. Further studies are warranted to expand on these findings.