Santosh Aparanji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Santosh Aparanji has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Vivek Jay Srinivasan
NYU Langone Health
5 shared publications - Mingjun Zhao
Tech4Health Institute, NYU Langone Health
4 shared publications Drew Hamilton
Tech4Health Institute, NYU Langone Health
2 shared publications- Aaron Sylvan Lord
Department of Neurology, New York University School of Medicine, New York, New York; Department of Neurosurgery, New York University School of Medicine, New York, New York
1 shared publication Akshay S. Nadig
NYU Langone Health, New York, NY, USA
1 shared publicationAkshay Shashidhar Nadig
Tech4Health Institute, NYU Langone Health
1 shared publication
Latest Publications
- 10 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (3) , 1241-1254
Highly parallel, 1060 nm interferometric diffusing wave spectroscopy with a time-of-flight filter
Interferometric diffuse optics (iDO) has recently emerged as a promising class of near-infrared (NIR) light technologies for monitoring human brain signals associated with coherent light fluctuations. In this work, we demonstrate a line scan interferometric diffusing wave spectroscopy (iDWS) system at 1060 nm, a wavelength that has a multitude of benefits for high-speed cerebral blood flow index (BFI) monitoring. Pulsatile BFI measurements on the forehead of a moderately dark-skinned (Fitzpatrick Type V) subject with medium-length black hair up to a source-collector (S-C) separation of 5.5 cm on the forehead and 4.0 cm over the parietal cortex are demonstrated in continuous wave (CW) mode. On this high-throughput platform, we further implement a simple time-of-flight filter (TOF) via source wavelength tuning. The TOF filter can be turned on and off, and its width can be changed electronically, enabling probing different sample depths without requiring multiple S-C separations. At 4 cm S-C separation, an electronic TOF filter afforded a 2.92-fold reduction in scalp sensitivity over CW mode. With further optimization, the combination of TOF filtering with highly parallel detection in the 1060 nm range promises to improve depth sensitivity and signal-to-noise ratio of iDO in neuromonitoring applications.
- 10 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (3) , 1241-1254
Highly parallel, 1060 nm interferometric diffusing wave spectroscopy with a time-of-flight filter
Interferometric diffuse optics (iDO) has recently emerged as a promising class of near-infrared (NIR) light technologies for monitoring human brain signals associated with coherent light fluctuations. In this work, we demonstrate a line scan interferometric diffusing wave spectroscopy (iDWS) system at 1060 nm, a wavelength that has a multitude of benefits for high-speed cerebral blood flow index (BFI) monitoring. Pulsatile BFI measurements on the forehead of a moderately dark-skinned (Fitzpatrick Type V) subject with medium-length black hair up to a source-collector (S-C) separation of 5.5 cm on the forehead and 4.0 cm over the parietal cortex are demonstrated in continuous wave (CW) mode. On this high-throughput platform, we further implement a simple time-of-flight filter (TOF) via source wavelength tuning. The TOF filter can be turned on and off, and its width can be changed electronically, enabling probing different sample depths without requiring multiple S-C separations. At 4 cm S-C separation, an electronic TOF filter afforded a 2.92-fold reduction in scalp sensitivity over CW mode. With further optimization, the combination of TOF filtering with highly parallel detection in the 1060 nm range promises to improve depth sensitivity and signal-to-noise ratio of iDO in neuromonitoring applications.
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 035005-21
Comparison of diffuse correlation spectroscopy, interferometric diffusing wave spectroscopy, and speckle contrast optical spectroscopy for blood flow monitoring
The speckle fluctuations of diffuse light facilitate noninvasive measurement of blood flow in deep tissues at the bedside. Until recently, the predominant technique employed for this purpose has been diffuse correlation spectroscopy (DCS). The traditional DCS methodology obtains the temporal intensity autocorrelation function of one or a few speckles of diffuse light and models transport of the electric field temporal correlation function through tissue with the correlation diffusion equation.1,2 DCS can then extract tissue blood flow information by fitting the autocorrelation function decay rate of light intensity to solutions of the correlation diffusion equation.2 – 9
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 035005-21
Open AccessComparison of diffuse correlation spectroscopy, interferometric diffusing wave spectroscopy, and speckle contrast optical spectroscopy for blood flow monitoring
The speckle fluctuations of diffuse light facilitate noninvasive measurement of blood flow in deep tissues at the bedside. Until recently, the predominant technique employed for this purpose has been diffuse correlation spectroscopy (DCS). The traditional DCS methodology obtains the temporal intensity autocorrelation function of one or a few speckles of diffuse light and models transport of the electric field temporal correlation function through tissue with the correlation diffusion equation.1,2 DCS can then extract tissue blood flow information by fitting the autocorrelation function decay rate of light intensity to solutions of the correlation diffusion equation.2 – 9
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 31 (4: Adv. in) , 1-13
Comprehensive Optimization of Interferometric Diffusing Wave Spectroscopy (iDWS)
Light speckle fluctuations provide a means for noninvasive measurements of cerebral blood flow index (CBFi). While conventional Diffuse Correlation Spectroscopy (DCS) quantifies these fluctuations to provide marginal brain sensitivity for CBFi in adult humans, new techniques have emerged to improve diffuse light throughput and brain sensitivity. Here we further optimize one such approach, interferometric diffusing wave spectroscopy (iDWS), with respect to the number of independent channels, camera duty cycle and full well capacity, incident laser power, noise and artifact mitigation, and data processing. We build the system on a cart and define conditions for stable operation. We show pulsatile CBFi monitoring at 4-4.5 cm source-collector separation in adults with moderate pigmentation (Fitzpatrick 4). We also report preliminary clinical measurements of patient CBFi in the Neuro Intensive Care Unit (Neuro ICU). These results push the boundaries of iDWS CBFi monitoring performance beyond previous reports.
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 31 (4: Adv. in) , 1-13
Comprehensive Optimization of Interferometric Diffusing Wave Spectroscopy (iDWS)
Light speckle fluctuations provide a means for noninvasive measurements of cerebral blood flow index (CBFi). While conventional Diffuse Correlation Spectroscopy (DCS) quantifies these fluctuations to provide marginal brain sensitivity for CBFi in adult humans, new techniques have emerged to improve diffuse light throughput and brain sensitivity. Here we further optimize one such approach, interferometric diffusing wave spectroscopy (iDWS), with respect to the number of independent channels, camera duty cycle and full well capacity, incident laser power, noise and artifact mitigation, and data processing. We build the system on a cart and define conditions for stable operation. We show pulsatile CBFi monitoring at 4-4.5 cm source-collector separation in adults with moderate pigmentation (Fitzpatrick 4). We also report preliminary clinical measurements of patient CBFi in the Neuro Intensive Care Unit (Neuro ICU). These results push the boundaries of iDWS CBFi monitoring performance beyond previous reports.
- 28 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (7) , 2382-2385
1060 nm interferometric near-infrared spectroscopy
Recently, interferometric near-infrared spectroscopy (iNIRS) has emerged to measure diffuse light field fluctuations with time-of-flight (TOF) resolution. Yet, current iNIRS implementations suffer from low signal-to-noise ratio (SNR). Longer wavelengths, with lower photon energy, lower reduced scattering in biological tissues, and higher permissible exposures, have the potential to increase SNR. Here, we investigate iNIRS at 1060 nm. Across various forehead locations, we find that the autocorrelation SNR is improved 3.7–9.3 times compared to 855 nm and 6.0–33.5 times compared to 773 nm at TOFs of 800–1000 ps. Physical system parameters account for much of this improvement, but the tissue response may also play a role. We conclude that wavelengths near 1060 nm can potentially improve iNIRS measurements of TOF-resolved speckle fluctuations.
- 28 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (7) , 2382-2385
1060 nm interferometric near-infrared spectroscopy
Recently, interferometric near-infrared spectroscopy (iNIRS) has emerged to measure diffuse light field fluctuations with time-of-flight (TOF) resolution. Yet, current iNIRS implementations suffer from low signal-to-noise ratio (SNR). Longer wavelengths, with lower photon energy, lower reduced scattering in biological tissues, and higher permissible exposures, have the potential to increase SNR. Here, we investigate iNIRS at 1060 nm. Across various forehead locations, we find that the autocorrelation SNR is improved 3.7–9.3 times compared to 855 nm and 6.0–33.5 times compared to 773 nm at TOFs of 800–1000 ps. Physical system parameters account for much of this improvement, but the tissue response may also play a role. We conclude that wavelengths near 1060 nm can potentially improve iNIRS measurements of TOF-resolved speckle fluctuations.
- 14 November 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (22) , 6056-6059
Decoding diffuse light scattering dynamics in layered tissues: path length versus fluctuation time scale
Dynamic multiple light scattering (DMLS) has found numerous applications, including soft matter physics and biomedical optics. Yet biological tissues may have complex internal geometries, presenting a challenge for noninvasive measurements. Deciphering laminar dynamics is crucial to accurately interpret tissue or organ physiology. Seminal DMLS work noted that one can probe deeper layers indirectly by analyzing light fluctuations on shorter time scales. Recent technologies have enabled probing deeper layers directly by analyzing fluctuations at longer path lengths. The following question arises: are the indirect and direct approaches synergistic or redundant? Here, by adding an optical switch to path-length-filtered interferometric diffusing wave spectroscopy, we experimentally address this question in the context of a forearm occlusion study. We find that both approaches afford better distinction of light scattering dynamics in layered tissues than either approach alone. This motivates further development of methods that integrate both decorrelation time scale and light path length to probe layered tissues.
- 14 November 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (22) , 6056-6059
Decoding diffuse light scattering dynamics in layered tissues: path length versus fluctuation time scale
Dynamic multiple light scattering (DMLS) has found numerous applications, including soft matter physics and biomedical optics. Yet biological tissues may have complex internal geometries, presenting a challenge for noninvasive measurements. Deciphering laminar dynamics is crucial to accurately interpret tissue or organ physiology. Seminal DMLS work noted that one can probe deeper layers indirectly by analyzing light fluctuations on shorter time scales. Recent technologies have enabled probing deeper layers directly by analyzing fluctuations at longer path lengths. The following question arises: are the indirect and direct approaches synergistic or redundant? Here, by adding an optical switch to path-length-filtered interferometric diffusing wave spectroscopy, we experimentally address this question in the context of a forearm occlusion study. We find that both approaches afford better distinction of light scattering dynamics in layered tissues than either approach alone. This motivates further development of methods that integrate both decorrelation time scale and light path length to probe layered tissues.
- 1 January 2016
- Published by Optica Publishing Group
- p. Th3A.20
On the Stability of Raman Fiber Lasers
We propose a physical mechanism behind recent, unexplained observations of deleterious temporal instability arising in Raman fiber lasers. We modelled the process and were able to simulate the threshold for instability at different pump-wavelengths.
- 1 January 2016
- Published by Optica Publishing Group
- p. Th3A.20
On the Stability of Raman Fiber Lasers
We propose a physical mechanism behind recent, unexplained observations of deleterious temporal instability arising in Raman fiber lasers. We modelled the process and were able to simulate the threshold for instability at different pump-wavelengths.