Mohsen Sharifzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohsen Sharifzadeh has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Paul S. Bernstein
Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
4 shared publications Werner Gellermann
Image Technologies Corporation, Salt Lake City, Utah, United States
4 shared publicationsIgor V. Ermakov
Department of Physics and Astronomy, University of Utah, Salt Lake City, Utah
3 shared publications- Werner Gellermann
Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112, USA
3 shared publications Maia R. Ermakova
The Univ. of Utah (United States)
2 shared publicationsPaul S. Bernstein
Department of Ophthalmology and Visual Sciences, Moran Eye Center, University of Utah School of Medicine, Salt Lake City, Utah, United States
2 shared publications
Latest Publications
- Open Access
- 6 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1751
Melanin Correction Is Essential for Quantitative Autofluorescence-Based Measurement of Macular Pigment
Macular pigment optical density (MPOD) is widely measured by dual-wavelength autofluorescence imaging (AFI) because the method is noninvasive, image-based, and clinically practical. AFI-derived MPOD and macular pigment optical volume (MPOV) are increasingly used as retinal biomarkers in clinical research, supplementation studies, disease-risk interpretation, and population-based comparisons. However, conventional dual-wavelength AFI assumes that posterior absorbers other than macular pigment (MP), particularly melanin, are negligible or sufficiently stable not to bias the measurement. This assumption may limit the diagnostic and biomarker reliability of AFI-derived MP metrics. This manuscript presents a focused biological, optical, and mathematical analysis of AFI-based MP quantification. The foundational AFI literature, the melanin imaging literature, retinal pigment epithelium (RPE) pigment biology, and related optical modeling concepts were examined to evaluate where melanin enters the AFI signal pathway, how it may confound MPOD and MPOV, and how a melanin-sensitive baseline could improve quantitative specificity within the AFI domain. Conventional dual-wavelength AFI estimates MP indirectly from attenuation of RPE lipofuscin autofluorescence under excitation wavelengths that differ in MP absorption. Because melanin is located in the RPE and choroid, varies with retinal location, age, and pigmentation, and can influence the same excitation and detection pathway, unmeasured melanin can become embedded in the apparent MPOD signal. Under these conditions, reported MPOD and derived MPOV are better understood as model-dependent estimates whose quantitative specificity may vary across subjects, retinal locations, devices, and studies. This has direct implications for diagnostic interpretation, normative databases, cross-subject comparison, supplementation-response studies, and biomarker-based retinal assessment. Melanin correction is not a minor refinement of AFI-based MP quantification. It is likely necessary when AFI-derived MP metrics are intended to be interpreted as quantitatively specific retinal biomarkers rather than conditionally approximate optical estimates. A melanin-corrected AFI framework, based on introducing a melanin-sensitive baseline wavelength outside the principal MP absorption range, offers a path toward more reliable MPOD and MPOV interpretation in clinical, diagnostic, and supplementation-related studies.
- 6 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1751
Open AccessMelanin Correction Is Essential for Quantitative Autofluorescence-Based Measurement of Macular Pigment
Macular pigment optical density (MPOD) is widely measured by dual-wavelength autofluorescence imaging (AFI) because the method is noninvasive, image-based, and clinically practical. AFI-derived MPOD and macular pigment optical volume (MPOV) are increasingly used as retinal biomarkers in clinical research, supplementation studies, disease-risk interpretation, and population-based comparisons. However, conventional dual-wavelength AFI assumes that posterior absorbers other than macular pigment (MP), particularly melanin, are negligible or sufficiently stable not to bias the measurement. This assumption may limit the diagnostic and biomarker reliability of AFI-derived MP metrics. This manuscript presents a focused biological, optical, and mathematical analysis of AFI-based MP quantification. The foundational AFI literature, the melanin imaging literature, retinal pigment epithelium (RPE) pigment biology, and related optical modeling concepts were examined to evaluate where melanin enters the AFI signal pathway, how it may confound MPOD and MPOV, and how a melanin-sensitive baseline could improve quantitative specificity within the AFI domain. Conventional dual-wavelength AFI estimates MP indirectly from attenuation of RPE lipofuscin autofluorescence under excitation wavelengths that differ in MP absorption. Because melanin is located in the RPE and choroid, varies with retinal location, age, and pigmentation, and can influence the same excitation and detection pathway, unmeasured melanin can become embedded in the apparent MPOD signal. Under these conditions, reported MPOD and derived MPOV are better understood as model-dependent estimates whose quantitative specificity may vary across subjects, retinal locations, devices, and studies. This has direct implications for diagnostic interpretation, normative databases, cross-subject comparison, supplementation-response studies, and biomarker-based retinal assessment. Melanin correction is not a minor refinement of AFI-based MP quantification. It is likely necessary when AFI-derived MP metrics are intended to be interpreted as quantitatively specific retinal biomarkers rather than conditionally approximate optical estimates. A melanin-corrected AFI framework, based on introducing a melanin-sensitive baseline wavelength outside the principal MP absorption range, offers a path toward more reliable MPOD and MPOV interpretation in clinical, diagnostic, and supplementation-related studies.
- Open Access
Why Skin Carotenoid Measurements Cannot Serve as a Proxy for Macular Pigment Optical Density (MPOD): A Biochemical, Anatomical, Optical, and Statistical Review
Carotenoids accumulate in both the skin and the macula, but their biochemical specificity, anatomical localization, optical environments, and temporal kinetics differ fundamentally. Despite superficial similarities, these distinctions raise questions about whether non-invasive skin carotenoid measurements, which are obtained using reflection spectroscopy or resonance Raman spectroscopy, can meaningfully reflect macular pigment optical density (MPOD), a retina-specific biomarker associated with visual performance and neuroprotective function. This review synthesizes evidence across biochemistry, tissue distribution, optical pathways, kinetic behavior, and statistical correlations to evaluate this proposed relationship. Skin carotenoid measurements capture a broad mixture of dietary carotenoids, which are dominated by β-carotene and lycopene, that accumulate superficially within the epidermis and dermis and respond rapidly to short-term dietary and environmental changes. In contrast, MPOD reflects only lutein, zeaxanthin, and meso-zeaxanthin, which are selectively transported into the foveal neurosensory retina and change slowly through regulated retinal uptake and deposition. Across human studies, correlations between skin carotenoids and MPOD are weak, inconsistent, and biologically implausible, with large cohort analyses demonstrating near-zero associations. Collectively, evidence across biochemical, anatomical, optical, physiological, and statistical domains shows that skin carotenoid values encode general systemic antioxidant exposure, whereas MPOD reflects a highly localized, retina-specific carotenoid reservoir. Therefore, skin carotenoid measurements cannot be used to estimate, substitute for, or infer macular pigment levels. Accurate assessment of MPOD requires direct retinal imaging technologies.
Open AccessWhy Skin Carotenoid Measurements Cannot Serve as a Proxy for Macular Pigment Optical Density (MPOD): A Biochemical, Anatomical, Optical, and Statistical Review
Carotenoids accumulate in both the skin and the macula, but their biochemical specificity, anatomical localization, optical environments, and temporal kinetics differ fundamentally. Despite superficial similarities, these distinctions raise questions about whether non-invasive skin carotenoid measurements, which are obtained using reflection spectroscopy or resonance Raman spectroscopy, can meaningfully reflect macular pigment optical density (MPOD), a retina-specific biomarker associated with visual performance and neuroprotective function. This review synthesizes evidence across biochemistry, tissue distribution, optical pathways, kinetic behavior, and statistical correlations to evaluate this proposed relationship. Skin carotenoid measurements capture a broad mixture of dietary carotenoids, which are dominated by β-carotene and lycopene, that accumulate superficially within the epidermis and dermis and respond rapidly to short-term dietary and environmental changes. In contrast, MPOD reflects only lutein, zeaxanthin, and meso-zeaxanthin, which are selectively transported into the foveal neurosensory retina and change slowly through regulated retinal uptake and deposition. Across human studies, correlations between skin carotenoids and MPOD are weak, inconsistent, and biologically implausible, with large cohort analyses demonstrating near-zero associations. Collectively, evidence across biochemical, anatomical, optical, physiological, and statistical domains shows that skin carotenoid values encode general systemic antioxidant exposure, whereas MPOD reflects a highly localized, retina-specific carotenoid reservoir. Therefore, skin carotenoid measurements cannot be used to estimate, substitute for, or infer macular pigment levels. Accurate assessment of MPOD requires direct retinal imaging technologies.
- Open Access
- 12 November 2024
- Published by Optica Publishing Group in Optica Open
A Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- 12 November 2024
- Published by Optica Publishing Group in Optica Open
Open AccessA Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- Open Access
- 7 October 2024
- Published by Optica Publishing Group in Optica Open
A Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- 7 October 2024
- Published by Optica Publishing Group in Optica Open
Open AccessA Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- Open Access
- 7 October 2024
- Published by Optica Publishing Group in Optica Open
A Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- 7 October 2024
- Published by Optica Publishing Group in Optica Open
Open AccessA Theoretical Approach for Diagnosing Keratoconus Using Purkinje Image Geometry: An Accessible Method for Low-Cost and Early Detection
Purpose: To develop and evaluate a theoretical method for diagnosing keratoconus by analyzing the geometric properties of Purkinje images, with a focus on the displacement and distortion of the first Purkinje image (P1). Methods: Purkinje images are captured using near-infrared LEDs integrated into attachments for existing fundus cameras or stand-alone devices. Image processing techniques are employed to measure P1 displacement and distortion. A composite scoring system quantifies keratoconus severity, and data augmentation simulates diverse corneal shapes for robust diagnostic comparisons. Results: Simulated analysis demonstrated that the method effectively differentiates between healthy and keratoconic corneas by assessing key metrics such as Euclidean distance, eccentricity, area, and perimeter of P1. The scoring system consistently reflected keratoconus severity, with higher scores indicating greater deviation from normal corneal profiles. Conclusions: This study presents a promising, low-cost approach to diagnosing keratoconus using Purkinje image analysis. The method's adaptability and potential for early detection make it particularly suitable for low-resource settings. Translational Relevance: This method bridges the gap between basic research and clinical care by providing an affordable and accessible diagnostic tool for early keratoconus detection, especially in underserved regions.
- Open Access
- 24 April 2024
- Published by Elsevier in Ophthalmology Science
- Vol. 4 (5) , 100537
Ocular Effects of Prenatal Carotenoid Supplementation in the Mother and Her Child: The Lutein and Zeaxanthin in Pregnancy (L-ZIP) Randomized Trial - Report Number 2
- 24 April 2024
- Published by Elsevier in Ophthalmology Science
- Vol. 4 (5) , 100537
Open AccessOcular Effects of Prenatal Carotenoid Supplementation in the Mother and Her Child: The Lutein and Zeaxanthin in Pregnancy (L-ZIP) Randomized Trial - Report Number 2
- Open Access
- 1 June 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 59 (7) , 3011-3019
Grade of Cataract and Its Influence on Measurement of Macular Pigment Optical Density Using Autofluorescence Imaging
Purpose: To evaluate the influence of cataracts on measuring macular pigment optical density (MPOD) using a dual-wavelength confocal scanning autofluorescence imaging technique and to establish methods to compensate for the influence of cataracts. Methods: This prospective case series comprised 100 eyes that underwent cataract surgery. Cataracts were graded based on the World Health Organization classification. MPOD levels were measured with the MPOD module of the Spectralis MultiColor instrument (Spectralis-MP), pre- and postoperatively. We investigated the relationship between change in MPOD values and age, cataract grade, and quality of autofluorescence images. Local MPOD levels were evaluated for four strategically chosen eccentricities within the macular region, and the total MPOD volume was evaluated within 8.98° eccentricity from the center. Results: MPOD levels could be obtained in 67 eyes before surgery. Local and volume MPOD levels were higher postoperatively relative to preoperatively in all eyes. The mean ratio of local MPOD levels after and before surgery (correction factor, CF) ranged from 1.42 to 1.77, with larger CFs required for eccentricities closer to the foveal center. The CF for the MPOD volume was 1.31. Age, grade of nuclear cataract (NUC), posterior subcapsular opacity, and image quality index (IQI) significantly contributed to CFs. For example, regression equation for CF at 0.23° = 0.17 + 0.16 × IQI + 0.29 × NUC grade + 0.01 × age (P < 0.001). Conclusions: Cataracts affected MPOD measurements with the Spectralis-MP, but corrected MPOD results could be obtained via regression equations.
- 1 June 2018
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 59 (7) , 3011-3019
Open AccessGrade of Cataract and Its Influence on Measurement of Macular Pigment Optical Density Using Autofluorescence Imaging
Purpose: To evaluate the influence of cataracts on measuring macular pigment optical density (MPOD) using a dual-wavelength confocal scanning autofluorescence imaging technique and to establish methods to compensate for the influence of cataracts. Methods: This prospective case series comprised 100 eyes that underwent cataract surgery. Cataracts were graded based on the World Health Organization classification. MPOD levels were measured with the MPOD module of the Spectralis MultiColor instrument (Spectralis-MP), pre- and postoperatively. We investigated the relationship between change in MPOD values and age, cataract grade, and quality of autofluorescence images. Local MPOD levels were evaluated for four strategically chosen eccentricities within the macular region, and the total MPOD volume was evaluated within 8.98° eccentricity from the center. Results: MPOD levels could be obtained in 67 eyes before surgery. Local and volume MPOD levels were higher postoperatively relative to preoperatively in all eyes. The mean ratio of local MPOD levels after and before surgery (correction factor, CF) ranged from 1.42 to 1.77, with larger CFs required for eccentricities closer to the foveal center. The CF for the MPOD volume was 1.31. Age, grade of nuclear cataract (NUC), posterior subcapsular opacity, and image quality index (IQI) significantly contributed to CFs. For example, regression equation for CF at 0.23° = 0.17 + 0.16 × IQI + 0.29 × NUC grade + 0.01 × age (P < 0.001). Conclusions: Cataracts affected MPOD measurements with the Spectralis-MP, but corrected MPOD results could be obtained via regression equations.
- Open Access
- 1 August 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (8) , 5568-5578
Interrelationships Between Maternal Carotenoid Status and Newborn Infant Macular Pigment Optical Density and Carotenoid Status
Purpose.: Deposition of the macular pigment carotenoids lutein and zeaxanthin in the human retina occurs early in life. In this study, we examined the interrelationships of maternal carotenoid status and newborn infant macular pigment levels and systemic carotenoid status. As a secondary measure, we also evaluated the effects of intrauterine growth restriction (IUGR) on carotenoid status in term newborn infants. Methods.: We measured mother and infant skin carotenoids using resonance Raman spectroscopy (RRS), serum carotenoids by HPLC, and mother breast milk carotenoids by HPLC. We measured infant macular pigment levels using noninvasive blue light reflectometry. Results.: We enrolled 30 healthy term infants, their mothers, and 10 IUGR infants and their mothers. A subset of 16 infants was imaged for macular pigment optical density (MPOD). Infant serum zeaxanthin levels correlated with MPOD (r = 0.68, P = 0.007). Mother serum zeaxanthin levels correlated with infant MPOD (r = 0.59, P = 0.032). Infant and mother serum lutein did not correlate with MPOD. Mother–infant correlations were found for total serum carotenoids (r = 0.42, P = 0.020) and skin carotenoids (r = 0.48, P = 0.001). No difference was seen between IUGR infants and controls in total serum or skin carotenoids. Mothers of IUGR infants had lower total serum carotenoids (P = 0.019) and breast milk carotenoids than controls (P = 0.006). Conclusions.: Our findings suggest that maternal zeaxanthin status may play a more important role than lutein status in macular pigment deposition in utero. Controlled trials are needed to determine whether maternal zeaxanthin prenatal supplementation can raise infant macular pigment levels and/or improve ocular function.
- 1 August 2013
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 54 (8) , 5568-5578
Open AccessInterrelationships Between Maternal Carotenoid Status and Newborn Infant Macular Pigment Optical Density and Carotenoid Status
Purpose.: Deposition of the macular pigment carotenoids lutein and zeaxanthin in the human retina occurs early in life. In this study, we examined the interrelationships of maternal carotenoid status and newborn infant macular pigment levels and systemic carotenoid status. As a secondary measure, we also evaluated the effects of intrauterine growth restriction (IUGR) on carotenoid status in term newborn infants. Methods.: We measured mother and infant skin carotenoids using resonance Raman spectroscopy (RRS), serum carotenoids by HPLC, and mother breast milk carotenoids by HPLC. We measured infant macular pigment levels using noninvasive blue light reflectometry. Results.: We enrolled 30 healthy term infants, their mothers, and 10 IUGR infants and their mothers. A subset of 16 infants was imaged for macular pigment optical density (MPOD). Infant serum zeaxanthin levels correlated with MPOD (r = 0.68, P = 0.007). Mother serum zeaxanthin levels correlated with infant MPOD (r = 0.59, P = 0.032). Infant and mother serum lutein did not correlate with MPOD. Mother–infant correlations were found for total serum carotenoids (r = 0.42, P = 0.020) and skin carotenoids (r = 0.48, P = 0.001). No difference was seen between IUGR infants and controls in total serum or skin carotenoids. Mothers of IUGR infants had lower total serum carotenoids (P = 0.019) and breast milk carotenoids than controls (P = 0.006). Conclusions.: Our findings suggest that maternal zeaxanthin status may play a more important role than lutein status in macular pigment deposition in utero. Controlled trials are needed to determine whether maternal zeaxanthin prenatal supplementation can raise infant macular pigment levels and/or improve ocular function.
- Open Access
- 1 February 2012
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 130 (2) , 259-260
Quantification of Macular Carotenoids Using Autofluorescence Imaging in Patients With Photosensitive Migraine and Benign Essential Blepharospasm
Photophobia describes light sensitivity or abnormal intolerance of light. Patients with photophobia avoid light because of pain or discomfort. Photophobia may be reported by individuals with conditions not necessarily affecting the eye. Two such conditions are migraine and benign essential blepharospasm.1,2 We have previously demonstrated that patients with migraine or blepharospasm are more light sensitive than age-matched control subjects.3
- 1 February 2012
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 130 (2) , 259-260
Open AccessQuantification of Macular Carotenoids Using Autofluorescence Imaging in Patients With Photosensitive Migraine and Benign Essential Blepharospasm
Photophobia describes light sensitivity or abnormal intolerance of light. Patients with photophobia avoid light because of pain or discomfort. Photophobia may be reported by individuals with conditions not necessarily affecting the eye. Two such conditions are migraine and benign essential blepharospasm.1,2 We have previously demonstrated that patients with migraine or blepharospasm are more light sensitive than age-matched control subjects.3