LLLuca Lombardo

Luca Lombardo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luca Lombardo has a total of 130 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Masseter Muscle Morphometric Changes After Botulinum Toxin Type A Injection: A Prospective 3-Month Study

    by Matteo Val, Ludovica Zucchini, Matteo Pollis, Luca Guarda-Nardini, Luca Lombardo, Daniele Manfredini, Anna Colonna

    Myofascial pain of the masticatory muscles, frequently associated with bruxism, is a prevalent condition with substantial impact on quality of life. Botulinum toxin type A (BoNT-A) is used as an adjunctive treatment for refractory cases, but the temporal pattern of masseter morphometric change after injection remained incompletely characterised. This prospective observational pilot study was designed and reported strictly as a 3D imaging and morphometric methodology study; clinical pain and patient-reported outcomes were outside its scope and were not assessed. Eleven adults with myofascial pain and bruxism received BoNT-A (100 U total: 30 U per masseter side, 20 U per anterior temporalis side). Structured-light 3D facial scans (EinScan H, Shining 3D) were acquired at baseline (T0), one month (T1), and three months (T2). A standardised masseter region of interest (“TGL area”) was defined using cutaneous landmarks (tragus, gonion, labial commissure). Measurement precision was confirmed by intra-session repeatability (0.083 ± 0.020 mm), registration accuracy (RMS error 0.189–0.200 mm), and excellent landmark reliability (mean ICC [3, 1] = 0.955, 95% CI: 0.843–0.991). Repeated-measures ANOVA showed a significant effect of time on bilateral surface displacement (F(1.85,18.52) = 14.39, p < 0.001, η2G = 0.44), with significant reductions at T1 (–0.716 ± 0.480 mm; p = 0.002, Hedges’ g = 2.03) and T2 (–0.847 ± 0.588 mm; p = 0.002, g = 1.96) relative to baseline, and no significant change between T1 and T2 (p = 1.000). Changes were bilaterally symmetric (symmetry index at T1: 0.231 ± 0.154 mm). These findings indicate that 3D structured-light scanning reliably detects subtle facial contour changes after BoNT-A injection and may complement clinical and patient-reported assessments; the pilot design and small sample preclude definitive conclusions.


  • Open Access

    Three-Dimensional Evaluation of Soft Tissues in Orthognathic Surgery: A Pilot Study of Digital Planning Predictability

    by Martina Rumpianesi, Carlotta Preite, Francesca Cremonini, Luisa Valente, Riccardo Tieghi, Luca Lombardo

    Three-dimensional (3D) facial scanning integrated with cone-beam computed tomography (CBCT) has improved digital planning and postoperative assessment in orthognathic surgery. This retrospective pilot study evaluated the accuracy of digital surgical planning, skeletal and soft-tissue movements, and postoperative edema evolution in 12 patients undergoing bimaxillary orthognathic surgery. Pre- and postoperative CBCT scans, facial scans, and virtual surgical plans were analyzed. Planning accuracy was assessed by comparing predicted and postoperative cephalometric measurements. Skeletal and soft-tissue displacements were evaluated using corresponding landmarks, while postoperative edema was evaluated through 3D facial scan superimposition. Before Bonferroni correction, significant differences were observed for the SNB angle (p = 0.005) and the Mandibular Plane Angle (p = 0.008); after adjustment, only the SNB angle remained statistically significant. Significant positive correlations between skeletal and soft-tissue displacements were found for Point B along the x-axis (ρ = 0.769, adjusted p = 0.048) and y-axis (ρ = 0.797, adjusted p = 0.032), and for Pogonion along the z-axis (ρ = 0.988, adjusted p < 0.016). No statistically significant differences in postoperative edema remained after Bonferroni correction. Overall, digital surgical planning showed good agreement between planned and postoperative outcomes, while 3D facial scanning proved useful for evaluating soft-tissue response.

  • Accuracy of Curve of Wilson Levelling and Posterior Tooth Inclination With Vestibular, Lingual Straight Wire Technique and Clear Aligners: A Retrospective Cohort Study

    by Francesca Cremonini, Rosita Tauro, Carlotta Preite, Enrico Albertini, Mario Palone, Luca Lombardo

    Objective: To evaluate the discrepancy between programmed and achieved posterior tooth inclination and to assess the accuracy of Curve of Wilson levelling and posterior tooth inclination in the mandibular arch across three different techniques: vestibular fixed appliance, lingual fixed appliance and aligners. Materials and Methods: Seventy‐five patients were retrospectively selected: 25 treated with the vestibular technique (SWM prescription), 25 treated with the lingual technique (STb), and 25 treated with F22 aligners. Intraoral scans were obtained to produce initial, planned and final models. Buccolingual crown inclination and the levelling of the COW were then assessed. Results: A significant discrepancy between programmed and achieved posterior tooth inclination was observed across all techniques ( p < 0.001), indicating incomplete expression of the programmed movement. Accuracy values for inclination ranged from 85% to 90% at the first and second premolars, with no statistically significant differences among techniques. At the molar level, vestibular and lingual techniques showed significantly higher accuracy than aligners, while second molars exhibited lower accuracy values across all techniques. Regarding COW levelling, the only significant difference was observed between the vestibular (89.3% ± 4.15%) and lingual (84.67% ± 7.36%) techniques. Conclusions: All techniques resulted in a reduction of posterior tooth inclination and a certain degree of COW levelling. However, a discrepancy between planned and achieved posterior tooth inclination was observed, indicating incomplete expression of the programmed movement. Differences among techniques emerged mainly at the molar level, where vestibular appliances showed the highest accuracy, whereas the lingual technique showed lower values for COW levelling.

  • Bits2Bites: Intra-oral Scans Occlusal Classification

    by Lorenzo Borghi, Luca Lumetti, Francesca Cremonini, Federico Rizzo, Costantino Grana, Luca Lombardo, Federico Bolelli


  • Open Access

    Factors influencing the accuracy of guided palatal miniscrew insertion in young adults

    by Mario Palone, Filippo Pepe, Claudia Grotteria, Francesca Cremonini, Giuliano Bortolo Maino, Luca Brucculeri, Luca Lombardo

    Objective: To evaluate the in vivo accuracy of guided palatal miniscrew insertion, focusing on the effect of insertion side, frontal insertion angle, and miniscrew length. Materials and methods: In all, 52 palatal miniscrews were inserted using computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides in 20 patients (average age: 19.74 years ± 6.83). Digital models were acquired after miniscrew insertion and scanbody application. Then, linear and angular discrepancies between planned and realized miniscrew positions were evaluated by superimposing the reference model with the final postinsertion model. Discrepancies are recorded and compared to absolute precision (hypothetical). The effect of side, frontal insertion angle, and miniscrew length on accuracy were investigated. Results: Mean linear total discrepancies were 1.10 ± 1.01 mm and 1.71 ± 1.10 mm at the miniscrew head and tip points, respectively. Mean angular discrepancies were 5.90 ± 6.06° in the transverse (XY), 2.65 ± 2.47° in the sagittal (YZ), and 3.02 ± 2.65° in the coronal (XZ) plane. All discrepancies were significantly different to absolute precision ( p < 0.001), although not to an extent considered clinically relevant. Neither side nor frontal insertion angle (clinical factors), or miniscrew length (structural factor) significantly impacted accuracy. Conclusion: CAD/CAM surgical guides ensured clinically acceptable accuracy despite significant deviations from absolute precision. The insertion side, frontal insertion angle, and miniscrew length had minimal influence on accuracy, and therefore on outcome. Further studies should explore the effects of additional clinical, procedural, anatomical, and structural variables.


  • Open Access

    Integration of a Fluoride- and Mint-Based Spray in Nighttime Aligner Therapy: Effects on Salivary Concentration and Biofilm

    by Francesca Cremonini, Anna Bernardi, Alberto Bernardi, Luca Lombardo

    Continuous use of clear aligners modifies the oral environment and may favor bacterial colonization. Integration of topical fluoride-based agents could strengthen enamel and reduce biofilm formation. This study evaluated the effects of a galenic fluoride-mint spray (225–250 ppm fluoride and 1–2% peppermint essential oil) on salivary fluoride concentration and bacterial biofilm during orthodontic treatment. Ten patients using 3D-printed nighttime aligners were enrolled. Saliva samples were analyzed with an ion-selective electrode (ISE) at baseline, immediately after inserting the sprayed aligners and after 15, 30, 45 min post application. Biofilm morphology was qualitatively assessed by scanning electron microscope (SEM) in three aligners: unused, worn 14 nights without spray, worn 14 nights with spray. Salivary fluoride increased from 0.7–0.8 mg/L at baseline to 5.96 mg/L when the spray was applied on a new aligner and 8.42 mg/L on a used aligner, then progressively decreased, returning close to baseline at 45 min with the new aligner and remaining higher with the used aligner. SEM images showed mature and heterogeneous biofilm on used aligners without the spray, while aligners with nightly spray application exhibited qualitatively reduced and less organized surface deposits. The fluoride- and mint-based spray rapidly increases salivary fluoride and reduces biofilm formation on nighttime clear aligners, improving preventive oral health during orthodontic treatment.


  • Open Access

    Comparison Between Measurements Taken on AI-Generated and Conventional Digital Models: A Retrospective Study

    by Enzo Pasciuti, Daniela Guiducci, Filippo Guidorizzi, Tecla Terenzio, Saverio Ceraulo, Filippo Pepe, Luca Ranieri, Francesca Cremonini, Luca Lombardo

    (1) Aim: To compare transverse dimensions measured on AI-generated intra-oral models and conventional digital intra-oral models. (2) Methods: A group of 38 patients treated with clear aligners was selected retrospectively from those whose records featured both AI-generated and conventional digital intra-oral models taken at the same timepoint. Transverse dimensions (inter-canine, inter-premolar, and inter-molar distances) on both upper and lower arches were evaluated and compared. Intra-class correlation index and paired t-test were applied to test the repeatability of measurements and statistically significant differences, respectively. Statistical significance was set at 0.05. (3) Results: Intra-class correlation index showed good repeatability. Paired t-test showed differences in measurements of the distances between the thicket area of gingiva on the palatal side of the upper first molar (p = 0.002), the gingival margin of the lower first molar (p = 0.014), and the mesio-vestibular cusps of the lower first molars (p = 0.019). (4) Conclusions: Transverse measurements were similar on AI-generated and conventional intra-oral .stl renderings. Statistical differences were found on posterior areas of both upper and lower dental arches, but are unlikely to be clinically significant.


  • Open Access

    Color Variation in 3D-Printed Orthodontic Aligners as a Compliance Indicator: A Prospective Pilot Study

    by Francesca Cremonini, Giuseppe Chiusolo, Filippo Pepe, Luca Lombardo

    Patient compliance remains a significant challenge in orthodontic treatment with clear aligners, as adherence to prescribed wear time is often suboptimal. This study investigated the potential of colorimetric analysis as a method to assess compliance with NOXI 3D-printed night-time aligners. Specifically, it evaluated color variations in polyamide aligners due to thermo-oxidation, using the RGB (Red, Green, Blue) color model as a non-invasive indicator. In total, 10 patients participated in this prospective study, wearing aligners for either 7 or 12 h daily over a 14-day period. Colorimetric measurements were collected via a smartphone-based application, and statistical analyses examined correlations between wear duration and color changes. The results revealed a significant association between a longer wear time and increased discoloration (p < 0.001), supporting the feasibility of RGB-based monitoring as a reliable compliance tool. However, individual variability in saliva composition, diet, and oral hygiene may have influenced the results, highlighting the need for further research into potential confounding variables. These findings underscore the promise of integrating digital monitoring technologies to improve adherence tracking and patient management in orthodontics. Future studies should refine the methodology and validate its efficacy in larger, more diverse populations.


  • Open Access

    A Simulation of the Biomechanical Behavior of Orthodontic Miniscrews for Infrazygomatic Anchorage: An In Vitro Study

    by Mario Palone, Davide Tucci, Marta Calza, Niki Arveda, Francesca Cremonini, Filippo Pepe, Luca Lombardo

    Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.

  • Open Access

    Force Expressed by 3D-Printed Aligners with Different Thickness and Design Compared to Thermoformed Aligners: An in Vitro Study

    by Francesca Cremonini, Carolina Pancari, Luca Brucculeri, Ariyan Karami Shabankare, Luca Lombardo

    (1) Background: Clear aligners are favored for their aesthetics in orthodontics, with newer 3D-printed technologies allowing the design of aligners with differential thicknesses and materials, offering advantages in terms of force distribution on the teeth, thereby optimizing treatment biomechanics. This study aimed to compare the initial and final forces of three types of 3D-printed aligners (with different thickness gradients and gingival margins) and traditional thermoformed aligners (with different gingival margins), evaluating stress relaxation and force consistency to determine which material and configuration may be optimal for better force distribution; (2) Methods: Twenty-seven 3D-printed aligners with three design variations and 18 thermoformed aligners were analyzed. Customized models were used to assess force at specific points on the upper incisor (1.1) and molar (2.6). A 3 h stress-relaxation test was conducted at 37 °C, and force data were recorded every second using a motorized compression stand. Statistical analysis was performed using ANOVA, post hoc tests, and Kruskal–Wallis tests for comparisons; (3) Results and Conclusions: Aligners with vertical and horizontal thickness gradients and a gingival margin trimmed 2 mm above the gingival contour exerted the highest forces, particularly at incisal/occlusal points. No significant differences in stress relaxation were observed. The force applied to the molars was consistently higher than the force applied to the incisors. These 3D-printed aligners with both horizontal and vertical gradients may offer a viable alternative to thermoformed aligners.