Anson Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anson Zhou has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Alan Mao
Department of Computer Science, Johns Hopkins University
1 shared publication - Andrea Cheng
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, USA
1 shared publication - Anthony Ho
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
1 shared publication Charlotte Cheng
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, USA
1 shared publication- Charlotte J. Cheng
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
1 shared publication - Chun Hei Ryan Chan
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, USA
1 shared publication
Latest Publications
- Open Access
- 29 January 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23 (1) , 45
Brain-computer interface commercialization
Background: Brain-computer interfaces (BCIs) have emerged as powerful tools to restore neurological function lost due to injury or degeneration. Despite scientific advancements, successful commercialization remains challenging. This article analyzes two rehabilitative BCIs—the Argus II retinal prosthesis by Second Sight and the ARC-IM spinal cord stimulation system by Onward Medical—as case studies to highlight critical factors influencing their commercialization outcomes. Main text: The Argus II, initially heralded as groundbreaking, restored partial vision to patients blinded by retinitis pigmentosa through direct retinal stimulation. Despite clinical success and initial regulatory approvals leveraging reduced barriers via humanitarian device exemptions, it struggled commercially due to an insufficient patient population, prohibitive manufacturing costs, and high procedural and postoperative rehabilitation costs. Physician adoption barriers, driven by the unfamiliar surgical procedure and reimbursement challenges, further limited its scalability, ultimately leading to market withdrawal. Conversely, Onward Medical adopted a phased commercialization approach with its ARC systems targeting spinal cord injuries. Initially releasing the non-invasive ARC-EX device, Onward built clinical traction and provider relationships, strategically fostering familiarity to minimize early risk and regulatory burden. Leveraging established spinal cord stimulation technology widely familiar to physicians, Onward positioned its invasive ARC-IM system more favorably for broader adoption. Despite remaining challenges, such as surgical complexity, postoperative rehabilitation infrastructure, and cost, this methodical strategy may significantly mitigate commercial and clinical barriers. Conclusion: Comparative analysis of Argus II and ARC-IM underscores that thoughtful commercialization strategies emphasizing phased product introduction, leveraging predicate technologies, and aligning closely with established clinical practices are essential to translating BCI technologies from scientific milestones into sustainable clinical solutions.
- 29 January 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23 (1) , 45
Open AccessBrain-computer interface commercialization
Background: Brain-computer interfaces (BCIs) have emerged as powerful tools to restore neurological function lost due to injury or degeneration. Despite scientific advancements, successful commercialization remains challenging. This article analyzes two rehabilitative BCIs—the Argus II retinal prosthesis by Second Sight and the ARC-IM spinal cord stimulation system by Onward Medical—as case studies to highlight critical factors influencing their commercialization outcomes. Main text: The Argus II, initially heralded as groundbreaking, restored partial vision to patients blinded by retinitis pigmentosa through direct retinal stimulation. Despite clinical success and initial regulatory approvals leveraging reduced barriers via humanitarian device exemptions, it struggled commercially due to an insufficient patient population, prohibitive manufacturing costs, and high procedural and postoperative rehabilitation costs. Physician adoption barriers, driven by the unfamiliar surgical procedure and reimbursement challenges, further limited its scalability, ultimately leading to market withdrawal. Conversely, Onward Medical adopted a phased commercialization approach with its ARC systems targeting spinal cord injuries. Initially releasing the non-invasive ARC-EX device, Onward built clinical traction and provider relationships, strategically fostering familiarity to minimize early risk and regulatory burden. Leveraging established spinal cord stimulation technology widely familiar to physicians, Onward positioned its invasive ARC-IM system more favorably for broader adoption. Despite remaining challenges, such as surgical complexity, postoperative rehabilitation infrastructure, and cost, this methodical strategy may significantly mitigate commercial and clinical barriers. Conclusion: Comparative analysis of Argus II and ARC-IM underscores that thoughtful commercialization strategies emphasizing phased product introduction, leveraging predicate technologies, and aligning closely with established clinical practices are essential to translating BCI technologies from scientific milestones into sustainable clinical solutions.
- Open Access
- 14 June 2024
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 16 (1) , 1-10
A do it yourself (DIY) point-of-care wrist ultrasound phantom for joint access training
Background: Joint access is essential for arthrocentesis, or joint aspiration of fluids. Joint treatments that are not performed properly can result in avoidable patient issues such as damage to the muscles, tendons, and blood vessels surrounding the joint. The use of ultrasound has become the gold standard for this procedure and proven to be a support in the skill learning process. However, success with this equipment, particularly in small joints like the wrist, depends on a clinician's capacity to recognize the crucial landmarks that guide these procedures. Prior to executing on a real patient, task trainers have proven to be an effective way for doctors to practice and prepare for procedures. However, shortcomings of current solutions include high purchase costs, incompatibility with ultrasound imaging, and low reusability. In addition, since this is a procedure that is not performed frequently, there may not be space or resources available in healthcare facilities to accommodate one at the point of care. This study aimed to close the existing gap by developing a DIY ultrasound compatible task trainer for wrist joint access training. Results: We developed a novel ultrasound compatible wrist joint model that can be made from sustainable materials and reusable parts, thus reducing the costs for acquisition and environmental impact. Our model, which was produced utilizing small-batch production methods, is made up of 3D-printed bones enclosed in an ultrasound-compatible gelatin mixture. It can be easily remade after each practice session, removing needle tracks that are visible under ultrasound for conventional phantoms. The ultrasonic properties of this model were tested through pixel brightness analysis and visual inspection of simulated anatomical structures. Conclusion: Our results report the advantages and limitations of the proposed model regarding production, practice, and ultrasound compatibility. While future work entails the transfer to patients of the same skill, this reusable and replicable model has proven, when presented to experts, to be successful in representing the physical characteristics and ultrasound profile of significant anatomical structures. This novel DIY product could be an effective alternative to teach procedures in the context of resource-restrained clinical simulation centers.
- 14 June 2024
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 16 (1) , 1-10
Open AccessA do it yourself (DIY) point-of-care wrist ultrasound phantom for joint access training
Background: Joint access is essential for arthrocentesis, or joint aspiration of fluids. Joint treatments that are not performed properly can result in avoidable patient issues such as damage to the muscles, tendons, and blood vessels surrounding the joint. The use of ultrasound has become the gold standard for this procedure and proven to be a support in the skill learning process. However, success with this equipment, particularly in small joints like the wrist, depends on a clinician's capacity to recognize the crucial landmarks that guide these procedures. Prior to executing on a real patient, task trainers have proven to be an effective way for doctors to practice and prepare for procedures. However, shortcomings of current solutions include high purchase costs, incompatibility with ultrasound imaging, and low reusability. In addition, since this is a procedure that is not performed frequently, there may not be space or resources available in healthcare facilities to accommodate one at the point of care. This study aimed to close the existing gap by developing a DIY ultrasound compatible task trainer for wrist joint access training. Results: We developed a novel ultrasound compatible wrist joint model that can be made from sustainable materials and reusable parts, thus reducing the costs for acquisition and environmental impact. Our model, which was produced utilizing small-batch production methods, is made up of 3D-printed bones enclosed in an ultrasound-compatible gelatin mixture. It can be easily remade after each practice session, removing needle tracks that are visible under ultrasound for conventional phantoms. The ultrasonic properties of this model were tested through pixel brightness analysis and visual inspection of simulated anatomical structures. Conclusion: Our results report the advantages and limitations of the proposed model regarding production, practice, and ultrasound compatibility. While future work entails the transfer to patients of the same skill, this reusable and replicable model has proven, when presented to experts, to be successful in representing the physical characteristics and ultrasound profile of significant anatomical structures. This novel DIY product could be an effective alternative to teach procedures in the context of resource-restrained clinical simulation centers.
- Open Access
Design and Evaluation of a Spoke-Based Double-Lumen Pediatric Gastrostomy Tube
Gastrostomy tubes (G-tubes) are the gold standard for feeding assistance for children with feeding dysfunction. Current G-tubes pose complications that interrupt the delivery of feed, including tube displacement and difficulty of at-home use. This study details an alternative, spoke-based, double-lumen G-tube design and preliminary validation of its function and usability. Pull force testing was performed on spoke G-tube models across three sizes and two classifications (hard/soft). Preliminary models were evaluated against market standards. Though the pull force of the spoke model was found to be lower than that of both market standards, hard modifications to the spoke model improved retentive force. Ease of use was tested amongst users unfamiliar with G-tube placement. The spoke design required 12.3 ± 4.7 s to deploy, less than half the time required for market standards. However, balloon G-tubes were still perceived to be easiest to use by 70% of participants, with indications that a spoke design may be easier to use if sized similarly to current G-tubes, with auxiliary improvements to factors such as grip. While there is a need for improvements in the material properties and manufacturing of the proposed design, this study provides early validation of the potential to address complications of existing G-tubes.
Open AccessDesign and Evaluation of a Spoke-Based Double-Lumen Pediatric Gastrostomy Tube
Gastrostomy tubes (G-tubes) are the gold standard for feeding assistance for children with feeding dysfunction. Current G-tubes pose complications that interrupt the delivery of feed, including tube displacement and difficulty of at-home use. This study details an alternative, spoke-based, double-lumen G-tube design and preliminary validation of its function and usability. Pull force testing was performed on spoke G-tube models across three sizes and two classifications (hard/soft). Preliminary models were evaluated against market standards. Though the pull force of the spoke model was found to be lower than that of both market standards, hard modifications to the spoke model improved retentive force. Ease of use was tested amongst users unfamiliar with G-tube placement. The spoke design required 12.3 ± 4.7 s to deploy, less than half the time required for market standards. However, balloon G-tubes were still perceived to be easiest to use by 70% of participants, with indications that a spoke design may be easier to use if sized similarly to current G-tubes, with auxiliary improvements to factors such as grip. While there is a need for improvements in the material properties and manufacturing of the proposed design, this study provides early validation of the potential to address complications of existing G-tubes.