Fatih Dzulfiqar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fatih Dzulfiqar has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ratno Nuryadi
Research Center for Photonics, Research Organization for Nanotechnology and Materials, National Research and Innovation Agency (BRIN), South Tangerang, Banten, Indonesia
3 shared publications - Hari Sumartono
Research Center for Transportation Technology, National Research and Innovation Agency (BRIN), South Tangerang, Banten, Indonesia
2 shared publications - Lia Aprilia
Research Center for Photonics, Research Organization for Nanotechnology and Materials, National Research and Innovation Agency (BRIN), South Tangerang, Banten, Indonesia
2 shared publications Mahfudz Al Huda
Research Center for Structural Strength Technology, National Research and Innovation Agency (BRIN), South Tangerang, Banten, Indonesia
2 shared publicationsAchmad Widodo
Mechanical Engineering Department, University of Diponegoro (UNDIP), Semarang, Central Java, Indonesia
1 shared publication- Agus Setiawan
Electrical Power Engineering Department, Institut Teknologi PLN, Jakarta 11750, Indonesia
1 shared publication
Latest Publications
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Development of a High-Sensitivity Microcontroller-Based Microcantilever Sensor System Using Direct Digital Synthesis Technology
Microcantilevers, as a class of Micro Electro Mechanical Systems (MEMS) sensors, exhibit remarkable sensitivity and are widely applied in environmental, physical, and biological sensing. In this work, we present the development of a highly sensitive microcontroller-based microcantilever sensor measurement system, leveraging the advantages of Direct Digital Synthesis (DDS) technology to enable real-time, precise, and repeatable measurements. The system integrates an AD9850 DDS module with an Arduino Nano V3 to generate and control a 0.5 V amplitude sine wave signal, amplified to approximately 10 V to actuate a piezoelectric element coupled to the microcantilever. The oscillatory response of the microcantilever is detected using a Wheatstone Bridge circuit, followed by signal rectification and digital conversion via the ADS1115 analog-to-digital converter. By combining hardware and software innovations, including realtime monitoring via Python, the system allows continuous tracking of the microcantilever’s resonance frequency, achieving a mass sensitivity of 7.66pg/Hz, a high signal-to-noise ratio (SNR) of 82.5 dB and demonstrating good repeatability. Integrating DDS technology with microcontroller-based control significantly advances MEMS sensor design, offering broad potential for diverse sensing applications.
- 2 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Development of a High-Sensitivity Microcontroller-Based Microcantilever Sensor System Using Direct Digital Synthesis Technology
Microcantilevers, as a class of Micro Electro Mechanical Systems (MEMS) sensors, exhibit remarkable sensitivity and are widely applied in environmental, physical, and biological sensing. In this work, we present the development of a highly sensitive microcontroller-based microcantilever sensor measurement system, leveraging the advantages of Direct Digital Synthesis (DDS) technology to enable real-time, precise, and repeatable measurements. The system integrates an AD9850 DDS module with an Arduino Nano V3 to generate and control a 0.5 V amplitude sine wave signal, amplified to approximately 10 V to actuate a piezoelectric element coupled to the microcantilever. The oscillatory response of the microcantilever is detected using a Wheatstone Bridge circuit, followed by signal rectification and digital conversion via the ADS1115 analog-to-digital converter. By combining hardware and software innovations, including realtime monitoring via Python, the system allows continuous tracking of the microcantilever’s resonance frequency, achieving a mass sensitivity of 7.66pg/Hz, a high signal-to-noise ratio (SNR) of 82.5 dB and demonstrating good repeatability. Integrating DDS technology with microcontroller-based control significantly advances MEMS sensor design, offering broad potential for diverse sensing applications.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20593-20601
Highly Sensitive Detection of Pb²⁺ in Water Using Phase Shift-Based Capacitive Sensor Immobilized With Graphene Oxide
Lead ion (Pb²⁺) contamination in water is a critical environmental and public health issue, posing serious risks to human health even at low concentrations. While conventional detection methods, such as atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS), provide high sensitivity, their reliance on sophisticated equipment limits their accessibility for broader use. This study introduces a novel phase shift-based capacitive sensor using interdigitated electrodes (IDEs) immobilized with graphene oxide (GO) for Pb²⁺ detection. The sensor leverages GO's large surface area and oxygen-containing functional groups to achieve a detection limit of 1.7 ppm and a sensitivity of 0.0556 °/ppm. Measurements revealed a strong linear correlation (R² > 0.946) between phase shift and Pb²⁺ concentration over a wide range (10–400 ppm), highlighting the sensor's linearity and reproducibility. This approach offers a simplified and cost-effective alternative to existing methods, supporting water quality monitoring and industrial safety applications.
- 16 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20593-20601
Highly Sensitive Detection of Pb²⁺ in Water Using Phase Shift-Based Capacitive Sensor Immobilized With Graphene Oxide
Lead ion (Pb²⁺) contamination in water is a critical environmental and public health issue, posing serious risks to human health even at low concentrations. While conventional detection methods, such as atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS), provide high sensitivity, their reliance on sophisticated equipment limits their accessibility for broader use. This study introduces a novel phase shift-based capacitive sensor using interdigitated electrodes (IDEs) immobilized with graphene oxide (GO) for Pb²⁺ detection. The sensor leverages GO's large surface area and oxygen-containing functional groups to achieve a detection limit of 1.7 ppm and a sensitivity of 0.0556 °/ppm. Measurements revealed a strong linear correlation (R² > 0.946) between phase shift and Pb²⁺ concentration over a wide range (10–400 ppm), highlighting the sensor's linearity and reproducibility. This approach offers a simplified and cost-effective alternative to existing methods, supporting water quality monitoring and industrial safety applications.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41981-41988
Improved Low Concentration Water Content Detection in Biodiesel Utilizing Phase-Shift-Based Capacitive Method
Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semi-cylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. Experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase shift magnitude in the sensor’s output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor’s practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 41981-41988
Improved Low Concentration Water Content Detection in Biodiesel Utilizing Phase-Shift-Based Capacitive Method
Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semi-cylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. Experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase shift magnitude in the sensor’s output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor’s practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods.
- Open Access
- 20 February 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (5) , 1721
Opportunity Assessment of Virtual Power Plant Implementation for Sustainable Renewable Energy Development in Indonesia Power System Network
Renewable energy sources have become one of the important roles for sustainable energy development. One of the promising mechanisms to deploy renewable energy is through a Virtual Power Plant (VPP), which can integrate various distributed renewable energy resources into a single controllable and deployable entity. This paper examines the opportunity for VPP adoption in Indonesia, which investigates the minimum implementation criteria, provides a gap analysis for VPP implementation, and proposes recommendations for VPP implementation in Indonesia. The implementation criteria are obtained from the literature review, including the lessons learned from other countries, and categorized into four aspects: regulatory, technical, economic, and social. The gap analysis is performed by evaluating the current state of Indonesia’s utility network in correlation with the VPP minimum implementation criteria and then provides a scoring matrix for each criterion. Lastly, the recommendations are arranged to narrow these gaps, organized into ten key focus points, and divided into four phases, initiation, preparation, piloting, and deployment, across a ten-year timeframe.
- 20 February 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (5) , 1721
Open AccessOpportunity Assessment of Virtual Power Plant Implementation for Sustainable Renewable Energy Development in Indonesia Power System Network
Renewable energy sources have become one of the important roles for sustainable energy development. One of the promising mechanisms to deploy renewable energy is through a Virtual Power Plant (VPP), which can integrate various distributed renewable energy resources into a single controllable and deployable entity. This paper examines the opportunity for VPP adoption in Indonesia, which investigates the minimum implementation criteria, provides a gap analysis for VPP implementation, and proposes recommendations for VPP implementation in Indonesia. The implementation criteria are obtained from the literature review, including the lessons learned from other countries, and categorized into four aspects: regulatory, technical, economic, and social. The gap analysis is performed by evaluating the current state of Indonesia’s utility network in correlation with the VPP minimum implementation criteria and then provides a scoring matrix for each criterion. Lastly, the recommendations are arranged to narrow these gaps, organized into ten key focus points, and divided into four phases, initiation, preparation, piloting, and deployment, across a ten-year timeframe.