Ana García-Álvarez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ana García-Álvarez has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Yolanda Posada Franco
Department of Medical Laboratory, Laboratory Medicine Institute, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC) Hospital Clínico San Carlos Madrid Spain
2 shared publications - Ander Regueiro
Cardiovascular Institute, Hospital Clinic, Institut D’investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), 08036 Barcelona, Spain
1 shared publication Antonia R. Pons Mas
Servicio de Análisis Clínicos, Hospital Universitari Son Espases , Mallorca , España
1 shared publicationAurora Blanco Font
Laboratori Clínic Territorial Metropolitana Sud, Hospital Universitari de Bellvitge , Barcelona , España
1 shared publication- Daniel Pereda
Department of Cardiovascular Surgery, Hospital Clínic, Barcelona, Spain
1 shared publication David Oteo
Emergency Department, Clínico San Carlos Hospital, Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 24 October 2025
- Published by Sociedad Espanola de Quimioterapia in Revista Española de Quimioterapia
- Vol. 38 (S1) , 5-10
Usefulness of monocyte distribution width (MDW) in enhancing diagnostic accuracy of infection among severely ill patients presenting to the emergency department
Sepsis remains a major cause of morbidity and mortality and continues to pose substantial diagnostic challenges in its early stages. Monocyte Distribution Width (MDW), a parameter automatically integrated into complete blood counts by next-generation haematology analysers, has emerged as a promising biomarker. This study evaluates the diagnostic performance of MDW compared with traditional markers (C-reactive protein and leukocyte count) and clinical scoring systems (SOFA and NEWS) in a cohort of critically ill patients presenting to a hospital emergency department, with the aim of distinguishing those with infection from those whose severity was attributable to other causes.
- 24 October 2025
- Published by Sociedad Espanola de Quimioterapia in Revista Española de Quimioterapia
- Vol. 38 (S1) , 5-10
Open AccessUsefulness of monocyte distribution width (MDW) in enhancing diagnostic accuracy of infection among severely ill patients presenting to the emergency department
Sepsis remains a major cause of morbidity and mortality and continues to pose substantial diagnostic challenges in its early stages. Monocyte Distribution Width (MDW), a parameter automatically integrated into complete blood counts by next-generation haematology analysers, has emerged as a promising biomarker. This study evaluates the diagnostic performance of MDW compared with traditional markers (C-reactive protein and leukocyte count) and clinical scoring systems (SOFA and NEWS) in a cohort of critically ill patients presenting to a hospital emergency department, with the aim of distinguishing those with infection from those whose severity was attributable to other causes.
- 25 June 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (6) , 997-1003
Reference intervals for reticulocyte count and derived reticulocyte parameters in a cohort of healthy adults
Introduction: Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.Methods: One hundred and seventy‐five healthy adults (18 to 62 years) were included. Subjects were collected from the blood donation centre of the Hospital Clínico San Carlos (Madrid, Spain) upon informed consent. Whole blood was collected and assayed for 14 haematological parameters on the Beckman Coulter DxH 900 analyzer in the haematology laboratory of the Clinical Analysis Department. RIs were established as per Clinical and Laboratory Standards Institute EP28‐A3c guidelines using three different statistical approaches.Results: RIs estimated using the non‐parametric method and the Harrell‐Davis bootstrap method were very similar. RIs estimated by the robust method were narrower. Gender partitioning was required for two haematological parameters (low haemoglobin density (LHD) and microcytic anaemia factor (MAF)). The rest of the parameters did not need to be partitioned according to Lahti's method.Conclusion: RIs have been established for 14 hematologic parameters of the reticulocyte profile for the Beckman Coulter DxH 900 haematology analyzer using a healthy cohort of adult subjects.
- 25 June 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (6) , 997-1003
Reference intervals for reticulocyte count and derived reticulocyte parameters in a cohort of healthy adults
Introduction: Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.Methods: One hundred and seventy‐five healthy adults (18 to 62 years) were included. Subjects were collected from the blood donation centre of the Hospital Clínico San Carlos (Madrid, Spain) upon informed consent. Whole blood was collected and assayed for 14 haematological parameters on the Beckman Coulter DxH 900 analyzer in the haematology laboratory of the Clinical Analysis Department. RIs were established as per Clinical and Laboratory Standards Institute EP28‐A3c guidelines using three different statistical approaches.Results: RIs estimated using the non‐parametric method and the Harrell‐Davis bootstrap method were very similar. RIs estimated by the robust method were narrower. Gender partitioning was required for two haematological parameters (low haemoglobin density (LHD) and microcytic anaemia factor (MAF)). The rest of the parameters did not need to be partitioned according to Lahti's method.Conclusion: RIs have been established for 14 hematologic parameters of the reticulocyte profile for the Beckman Coulter DxH 900 haematology analyzer using a healthy cohort of adult subjects.
- Open Access
- 19 February 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (6) , 1133-1137
Monocyte distribution width (MDW): study of reference values in blood donors
Objectives: Monocyte distribution width (MDW) is a new biomarker used as an early indicator of sepsis (ESId). It is often aids in the identification of patients who may develop sepsis. This study aims to establish the MDW reference interval (RI) within the healthy population of blood donors using EDTA-K2 as anticoagulant. Many hospitals use this biomarker as a means of identifying patients who present to the hospital with sepsis. Methods: A total of 274 samples obtained from healthy donors were analyzed. MDW measurements were taken within 2 h post-extraction. The RI was estimated using various statistical methodologies, including the recommended CLSI EP28-A3c guideline, non-parametric and robust methods, along with the Harrell-Davis bootstrap method applied to the entire sample. Results: The RI estimated through non-parametric method was 14.77 CI90 % (14.36–14.97)–21.13 CI90 % (20.89–21.68); RI using the robust method was 15.64–19.05 and RI using the Harrell-Davis bootstrap method was 14.73 CI90 % (14.53–14.92)–21.14 CI90 % (20.88–21.40). Conclusions: Based on clinical applicability, we recommend utilizing the RI derived from the non-parametric method, aligning with the CLSI recommendations. Furthermore, we consider that our results can be taken as a reference in other laboratories that serve a population similar to our study cohort.
- 19 February 2024
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 62 (6) , 1133-1137
Open AccessMonocyte distribution width (MDW): study of reference values in blood donors
Objectives: Monocyte distribution width (MDW) is a new biomarker used as an early indicator of sepsis (ESId). It is often aids in the identification of patients who may develop sepsis. This study aims to establish the MDW reference interval (RI) within the healthy population of blood donors using EDTA-K2 as anticoagulant. Many hospitals use this biomarker as a means of identifying patients who present to the hospital with sepsis. Methods: A total of 274 samples obtained from healthy donors were analyzed. MDW measurements were taken within 2 h post-extraction. The RI was estimated using various statistical methodologies, including the recommended CLSI EP28-A3c guideline, non-parametric and robust methods, along with the Harrell-Davis bootstrap method applied to the entire sample. Results: The RI estimated through non-parametric method was 14.77 CI90 % (14.36–14.97)–21.13 CI90 % (20.89–21.68); RI using the robust method was 15.64–19.05 and RI using the Harrell-Davis bootstrap method was 14.73 CI90 % (14.53–14.92)–21.14 CI90 % (20.88–21.40). Conclusions: Based on clinical applicability, we recommend utilizing the RI derived from the non-parametric method, aligning with the CLSI recommendations. Furthermore, we consider that our results can be taken as a reference in other laboratories that serve a population similar to our study cohort.
- Open Access
- 26 April 2021
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 2 (3) , 381-389
Gestión del proceso posanalítico en los laboratorios clínicos según los requisitos de la norma ISO 15189:2012. Consideraciones sobre la gestión de muestras clínicas, aseguramiento de la calidad en el proceso posanalítico y gestión de la información del laboratorio
Resumen: La norma ISO 15189:2012 exige una serie de requisitos en cuanto a la gestión de muestras clínicas, el aseguramiento de la calidad del proceso y la gestión de la información del laboratorio. Además, la entidad acreditadora, ENAC en España, tiene establecidas las condiciones para el uso de la marca en el informe de resultados del laboratorio acreditado. Las recomendaciones planteadas aplican a las actividades incluidas en el proceso posanalítico del laboratorio, así como al personal implicado. Se indican los criterios para que el laboratorio defina y documente el tiempo y las condiciones de retención de las muestras, para diseñar un control de calidad interno que verifique si las actividades posanalíticas alcanzan la calidad esperada, los requisitos que debe cumplir la gestión de la información y la necesidad de disponer de un plan de contingencia que asegure la comunicación de los resultados en todo momento. Asimismo, se describe el uso correcto de la marca de acreditación en los informes. Diversos gobiernos y sociedades científicas abogan por la obligatoriedad de la acreditación de los laboratorios clínicos. Siendo la norma ISO 15189 la más específica para demostrar su competencia técnica, es indispensable el conocimiento y la comprensión de sus requisitos para su correcta implantación.
- 26 April 2021
- Published by Walter de Gruyter GmbH in Advances in Laboratory Medicine / Avances en Medicina de Laboratorio
- Vol. 2 (3) , 381-389
Open AccessGestión del proceso posanalítico en los laboratorios clínicos según los requisitos de la norma ISO 15189:2012. Consideraciones sobre la gestión de muestras clínicas, aseguramiento de la calidad en el proceso posanalítico y gestión de la información del laboratorio
Resumen: La norma ISO 15189:2012 exige una serie de requisitos en cuanto a la gestión de muestras clínicas, el aseguramiento de la calidad del proceso y la gestión de la información del laboratorio. Además, la entidad acreditadora, ENAC en España, tiene establecidas las condiciones para el uso de la marca en el informe de resultados del laboratorio acreditado. Las recomendaciones planteadas aplican a las actividades incluidas en el proceso posanalítico del laboratorio, así como al personal implicado. Se indican los criterios para que el laboratorio defina y documente el tiempo y las condiciones de retención de las muestras, para diseñar un control de calidad interno que verifique si las actividades posanalíticas alcanzan la calidad esperada, los requisitos que debe cumplir la gestión de la información y la necesidad de disponer de un plan de contingencia que asegure la comunicación de los resultados en todo momento. Asimismo, se describe el uso correcto de la marca de acreditación en los informes. Diversos gobiernos y sociedades científicas abogan por la obligatoriedad de la acreditación de los laboratorios clínicos. Siendo la norma ISO 15189 la más específica para demostrar su competencia técnica, es indispensable el conocimiento y la comprensión de sus requisitos para su correcta implantación.
- 1 May 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (9) , e85-e86
MitraClip Implantation for Hemolytic Anemia Treatment After Surgical Mitral Valve Repair
- 1 May 2020
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 13 (9) , e85-e86
MitraClip Implantation for Hemolytic Anemia Treatment After Surgical Mitral Valve Repair