Yanbing Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanbing Lv has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Lin Song Li
Henan University
11 shared publications - Ruili Wu
Henan University
9 shared publications Ning Li
Institute of Advanced Displays and Imaging
8 shared publicationsHuaibin Shen
Key Lab for Special Functional Materials of Ministry of Education, School of Nanoscience and Materials Engineering Henan University Kaifeng China
6 shared publicationsYangchao Shi
Key Lab for Special Functional Materials of Ministry of Education, and School of Nanoscience and Materials Engineering
6 shared publications- Huaibin Shen
Key Laboratory for Special Functional Materials of Ministry of Education, National & Local Joint Engineering Research Center for High-efficiency Display and Lighting Technology, School of Nanoscience and Materials Engineering, Henan University, Kaifeng 475004, China
5 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Wiley in Exploration
- Vol. 6 (3)
Synthesis of Tris(Dimethylamino)Phosphine‐Based InP Quantum Dots and Their Application in Light‐Emitting Diodes: Progress and Perspectives
Indium phosphide (InP)‐based quantum dots (QDs) have emerged as promising cadmium‐free alternatives for next‐generation optoelectronic applications, particularly in quantum dot light‐emitting diodes (QLEDs). Tris(dimethylamino)phosphine ((DMA) 3 P) has gained attention as a low‐toxicity alternative to conventional precursors like tris(trimethylsilyl)phosphine ((TMS) 3 P) or toxic phosphine gas (PH 3 ) in the synthesis of InP QDs. However, InP core/shell QDs synthesized using (DMA) 3 P and their corresponding QLEDs currently exhibit inferior optical and electronic performance compared to their (TMS) 3 P‐based counterparts. This review provides a comprehensive analysis of the molecular structures and distinct reaction mechanisms of (TMS) 3 P and (DMA) 3 P during InP core nucleation. Then, we systematically address the key challenges in optimizing (DMA) 3 P‐derived InP QDs, including defect state passivation and carrier confinement, and summarize effective improvement strategies encompassing core modulation, core/shell structure design, and surface ligand engineering. Furthermore, we discuss critical issues in integrating these QDs into QLEDs, focusing on charge transport engineering and suppression of charge leakage. Finally, we outline the remaining challenges and prospects for advancing InP‐based QLEDs in displays and solid‐state lighting.
- 25 May 2026
- Published by Wiley in Exploration
- Vol. 6 (3)
Open AccessSynthesis of Tris(Dimethylamino)Phosphine‐Based InP Quantum Dots and Their Application in Light‐Emitting Diodes: Progress and Perspectives
Indium phosphide (InP)‐based quantum dots (QDs) have emerged as promising cadmium‐free alternatives for next‐generation optoelectronic applications, particularly in quantum dot light‐emitting diodes (QLEDs). Tris(dimethylamino)phosphine ((DMA) 3 P) has gained attention as a low‐toxicity alternative to conventional precursors like tris(trimethylsilyl)phosphine ((TMS) 3 P) or toxic phosphine gas (PH 3 ) in the synthesis of InP QDs. However, InP core/shell QDs synthesized using (DMA) 3 P and their corresponding QLEDs currently exhibit inferior optical and electronic performance compared to their (TMS) 3 P‐based counterparts. This review provides a comprehensive analysis of the molecular structures and distinct reaction mechanisms of (TMS) 3 P and (DMA) 3 P during InP core nucleation. Then, we systematically address the key challenges in optimizing (DMA) 3 P‐derived InP QDs, including defect state passivation and carrier confinement, and summarize effective improvement strategies encompassing core modulation, core/shell structure design, and surface ligand engineering. Furthermore, we discuss critical issues in integrating these QDs into QLEDs, focusing on charge transport engineering and suppression of charge leakage. Finally, we outline the remaining challenges and prospects for advancing InP‐based QLEDs in displays and solid‐state lighting.
- 22 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1383, 344924
One-pot fabrication of highly stable and luminescent InP quantum dots nanobeads through multifunctional polymer encapsulation for lateral flow immunoassay
- 22 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1383, 344924
One-pot fabrication of highly stable and luminescent InP quantum dots nanobeads through multifunctional polymer encapsulation for lateral flow immunoassay
- 21 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (43) , 24083-24092
Construction of a Core–Satellite Immunoassay with Homogeneous Magnet-Assisted Ratiometric Fluorescence for Highly Sensitive and Visual Detection of Inflammatory Factors
The development of in vitro diagnostics (IVD) has been characterized by a focus on efficiency and convenience in a variety of testing scenarios. Herein, the homogeneous magnet-assisted ratiometric fluorescence (HMRF) method was used to capture, recognize, and convert the signal of target inflammatory factors in the same reaction system, which achieves highly sensitive and visual detection of multiple inflammatory factors (C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6)). The aqueous green quantum dots (QDs)-magnetic microspheres (Fe3O4@Tri-layer QDs, three closely stacked QD layers) with high fluorescence and magnetic properties were prepared by the layer-by-layer (LBL) self-assembly method. These were combined with red silica-coated QDs (QDs@SiO2) to design a core-satellite immunoassay, yielding a visual ratiometric fluorescence signal ranging from green-yellow-red color. Under the optimal conditions, a wide linear range was achieved for CRP, PCT, and IL-6, with the limit of detection (LOD) of 50.0 pg/mL, 35.5 pg/mL, and 18.4 pg/mL, respectively. Furthermore, the core-satellite immunoassay demonstrated resistance to interference from common substances in blood, and the recoveries ranged from 105.8% to 109.7%, showing good specificity, accuracy, and stability. The HMRF assay was verified with 44 human serum samples of CRP, and the results were found to be in good agreement with the clinical method. The core-satellite immunoassay provides a new technical tool for the diagnosis and research of multiple diseases and is of great importance in the field of highly sensitive, rapid, and accurate IVD.
- 21 October 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (43) , 24083-24092
Construction of a Core–Satellite Immunoassay with Homogeneous Magnet-Assisted Ratiometric Fluorescence for Highly Sensitive and Visual Detection of Inflammatory Factors
The development of in vitro diagnostics (IVD) has been characterized by a focus on efficiency and convenience in a variety of testing scenarios. Herein, the homogeneous magnet-assisted ratiometric fluorescence (HMRF) method was used to capture, recognize, and convert the signal of target inflammatory factors in the same reaction system, which achieves highly sensitive and visual detection of multiple inflammatory factors (C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6)). The aqueous green quantum dots (QDs)-magnetic microspheres (Fe3O4@Tri-layer QDs, three closely stacked QD layers) with high fluorescence and magnetic properties were prepared by the layer-by-layer (LBL) self-assembly method. These were combined with red silica-coated QDs (QDs@SiO2) to design a core-satellite immunoassay, yielding a visual ratiometric fluorescence signal ranging from green-yellow-red color. Under the optimal conditions, a wide linear range was achieved for CRP, PCT, and IL-6, with the limit of detection (LOD) of 50.0 pg/mL, 35.5 pg/mL, and 18.4 pg/mL, respectively. Furthermore, the core-satellite immunoassay demonstrated resistance to interference from common substances in blood, and the recoveries ranged from 105.8% to 109.7%, showing good specificity, accuracy, and stability. The HMRF assay was verified with 44 human serum samples of CRP, and the results were found to be in good agreement with the clinical method. The core-satellite immunoassay provides a new technical tool for the diagnosis and research of multiple diseases and is of great importance in the field of highly sensitive, rapid, and accurate IVD.
- 24 August 2025
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 64 (35) , 17904-17915
Photodynamic-Driven Growth of Aqueous CdSe/ZnSe/ZnS//ZnS Quantum Dots for Inflammatory Factors Multiplexed Detection via a Ratiometric-Fluorescence Immunosensor
Core/shell quantum dots (QDs) with a low cadmium (Cd) content and an intermediate ZnSe-based shell have attracted significant attention due to their excellent fluorescence properties. However, their poor water and oxygen stability presents a major challenge for transferring QDs to the aqueous phase. Herein, we prepared CdSe/ZnSe/ZnS//ZnS core/shell/shell QDs exhibiting both high fluorescence and good stability through a photodynamically driven mild growth process conducted at low temperatures. Growing a thicker, wide bandgap ZnS shell can effectively limit the domain of the excitons within the core, preventing fluorescence bursting caused by the complexation of internal excitons during the ligand exchange process. Furthermore, the prepared red and green core/shell QDs were biofunctionalized to develop a ratiometric-fluorescent immunosensor for the quantitative detection of four inflammatory biomarkers: C-reactive protein (CRP), serum amyloid A (SAA), interleukin-6 (IL-6), and procalcitonin (PCT). The novel immunosensors detected CRP, SAA, PCT, and IL-6 antigens with a broad linear range and high sensitivity, reaching 0.128, 0.047, 0.041, and 0.047 ng/mL, respectively. Clinical validation of the proposed assay demonstrated its high accuracy in detecting serum samples. Based on tailored low Cd content CdSe/ZnSe/ZnS//ZnS QDs as fluorescent probes, this highly sensitive ratiometric-fluorescent immunosensor shows great potential for the quantitative detection of biomarkers in in vitro diagnostics.
- 24 August 2025
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 64 (35) , 17904-17915
Photodynamic-Driven Growth of Aqueous CdSe/ZnSe/ZnS//ZnS Quantum Dots for Inflammatory Factors Multiplexed Detection via a Ratiometric-Fluorescence Immunosensor
Core/shell quantum dots (QDs) with a low cadmium (Cd) content and an intermediate ZnSe-based shell have attracted significant attention due to their excellent fluorescence properties. However, their poor water and oxygen stability presents a major challenge for transferring QDs to the aqueous phase. Herein, we prepared CdSe/ZnSe/ZnS//ZnS core/shell/shell QDs exhibiting both high fluorescence and good stability through a photodynamically driven mild growth process conducted at low temperatures. Growing a thicker, wide bandgap ZnS shell can effectively limit the domain of the excitons within the core, preventing fluorescence bursting caused by the complexation of internal excitons during the ligand exchange process. Furthermore, the prepared red and green core/shell QDs were biofunctionalized to develop a ratiometric-fluorescent immunosensor for the quantitative detection of four inflammatory biomarkers: C-reactive protein (CRP), serum amyloid A (SAA), interleukin-6 (IL-6), and procalcitonin (PCT). The novel immunosensors detected CRP, SAA, PCT, and IL-6 antigens with a broad linear range and high sensitivity, reaching 0.128, 0.047, 0.041, and 0.047 ng/mL, respectively. Clinical validation of the proposed assay demonstrated its high accuracy in detecting serum samples. Based on tailored low Cd content CdSe/ZnSe/ZnS//ZnS QDs as fluorescent probes, this highly sensitive ratiometric-fluorescent immunosensor shows great potential for the quantitative detection of biomarkers in in vitro diagnostics.
- 4 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (31) , 16916-16924
Tailored Quantum Dots@Metal–Organic Frameworks for Enhanced Hypochlorite Detection in Live Cells and Ulcerative Colitis Diagnosis
Excess levels of hypochlorous acid/hypochlorite (HClO/ClO-) are associated with the development of tissue damage and the onset of various pathological conditions. The enzymatic reaction of myeloperoxidase produces HClO/ClO-, which is closely related to hepatic ulcerative colitis (UC). The detection of HClO is particularly important as it provides valuable insights into the early diagnosis of UC. In this study, we introduce a new class of quantum dot@metal-organic framework composites, specifically QD-PEI@ZIF-8, fabricated via the one-pot solvothermal method. These composites are based on aqueous quantum dots (QDs) of surface amine ligands (QD-PEI), which promote the epitaxial growth of zeolitic imidazolate framework (ZIF-8) structures. The resulting QD-PEI@ZIF-8 composites demonstrate enhanced optical properties and stability. The highly porous QD-PEI@ZIF-8 composites exhibit better specificity for ion selection and improve detection sensitivity. The fluorescence burst of the QD-PEI@ZIF-8 composite enabled highly specific detection of ClO-, covering a wide linear range from 10 to 120 μM, and its limit of detection (LOD) was improved to 0.38 μM, representing a 36-fold enhancement in sensitivity compared to the QD-PEI. Furthermore, the QD-PEI@ZIF-8 composite was validated for live cell imaging applications. By optimization of the detection conditions, a "sampling-detecting" capillary sensor for ClO- detection in the fecal samples from both mice and human subjects with UC disease was developed. This strategy provides a novel QD-PEI@ZIF-8 composite and capillary sensor for specific, sensitive, and efficient detection of HClO/ClO-, with implications for both cellular regulation and detection of UC diseases.
- 4 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (31) , 16916-16924
Tailored Quantum Dots@Metal–Organic Frameworks for Enhanced Hypochlorite Detection in Live Cells and Ulcerative Colitis Diagnosis
Excess levels of hypochlorous acid/hypochlorite (HClO/ClO-) are associated with the development of tissue damage and the onset of various pathological conditions. The enzymatic reaction of myeloperoxidase produces HClO/ClO-, which is closely related to hepatic ulcerative colitis (UC). The detection of HClO is particularly important as it provides valuable insights into the early diagnosis of UC. In this study, we introduce a new class of quantum dot@metal-organic framework composites, specifically QD-PEI@ZIF-8, fabricated via the one-pot solvothermal method. These composites are based on aqueous quantum dots (QDs) of surface amine ligands (QD-PEI), which promote the epitaxial growth of zeolitic imidazolate framework (ZIF-8) structures. The resulting QD-PEI@ZIF-8 composites demonstrate enhanced optical properties and stability. The highly porous QD-PEI@ZIF-8 composites exhibit better specificity for ion selection and improve detection sensitivity. The fluorescence burst of the QD-PEI@ZIF-8 composite enabled highly specific detection of ClO-, covering a wide linear range from 10 to 120 μM, and its limit of detection (LOD) was improved to 0.38 μM, representing a 36-fold enhancement in sensitivity compared to the QD-PEI. Furthermore, the QD-PEI@ZIF-8 composite was validated for live cell imaging applications. By optimization of the detection conditions, a "sampling-detecting" capillary sensor for ClO- detection in the fecal samples from both mice and human subjects with UC disease was developed. This strategy provides a novel QD-PEI@ZIF-8 composite and capillary sensor for specific, sensitive, and efficient detection of HClO/ClO-, with implications for both cellular regulation and detection of UC diseases.
- Open Access
- 1 August 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (9)
Construction of a magnetic driven-quantum dots ratiometric fluorescence-immunosensor for rapid and accurate detection of C-reactive protein
Efficient, sensitive, and convenient quantum dots (QDs) fluorescent immunosensors have a wide range of applications in the field of in vitro diagnostics (IVD). However, traditional single-signal readout methods are susceptible to interference, have limited sensitivity, and involve time-consuming detection processes. These have become key bottlenecks restricting their use in point-of-care (POC) detection. Herein, we developed a novel immunosensor based on QDs ratiometric fluorescence (QRF) and magnetic driven technology for sensitive, rapid, accurate detection of C-reactive protein (CRP). High-quality magnetic-fluorescent QDs nanobeads (QBs) were prepared by efficiently and orderly layered loading of magnetic nanoparticles (MNP) and red QDs using mesoporous silica nanoparticles (MSN) as a template. The magnetic driven-QRF-immunosensor was constructed based on green QDs probes-functionalized microplate. The results showed that the linear range of magnetic-fluorescence probes for the detection of CRP was 0.1-1,000 ng/mL, with a sensitivity of up to 0.05 ng/mL. Compared to conventional QRF-immunosensor, the detection time was halved (within 30 min), and the sensitivity improved by approximately 5-fold. Recovery experiments and clinical sample analyses also demonstrated the good accuracy of this immunoassay. Therefore, the constructed novel magnetic driven-QRF-immunosensor shows great potential for clinical diagnosis and disease monitoring, and is expected to be applied in POC detection as a new generation of detection technology.
- 1 August 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (9)
Open AccessConstruction of a magnetic driven-quantum dots ratiometric fluorescence-immunosensor for rapid and accurate detection of C-reactive protein
Efficient, sensitive, and convenient quantum dots (QDs) fluorescent immunosensors have a wide range of applications in the field of in vitro diagnostics (IVD). However, traditional single-signal readout methods are susceptible to interference, have limited sensitivity, and involve time-consuming detection processes. These have become key bottlenecks restricting their use in point-of-care (POC) detection. Herein, we developed a novel immunosensor based on QDs ratiometric fluorescence (QRF) and magnetic driven technology for sensitive, rapid, accurate detection of C-reactive protein (CRP). High-quality magnetic-fluorescent QDs nanobeads (QBs) were prepared by efficiently and orderly layered loading of magnetic nanoparticles (MNP) and red QDs using mesoporous silica nanoparticles (MSN) as a template. The magnetic driven-QRF-immunosensor was constructed based on green QDs probes-functionalized microplate. The results showed that the linear range of magnetic-fluorescence probes for the detection of CRP was 0.1-1,000 ng/mL, with a sensitivity of up to 0.05 ng/mL. Compared to conventional QRF-immunosensor, the detection time was halved (within 30 min), and the sensitivity improved by approximately 5-fold. Recovery experiments and clinical sample analyses also demonstrated the good accuracy of this immunoassay. Therefore, the constructed novel magnetic driven-QRF-immunosensor shows great potential for clinical diagnosis and disease monitoring, and is expected to be applied in POC detection as a new generation of detection technology.
- 12 March 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1352, 343931
DNA nanowires-mediated high sensitive quantum dot-fluorescence-linked immunoassay for proteins analysis
- 12 March 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1352, 343931
DNA nanowires-mediated high sensitive quantum dot-fluorescence-linked immunoassay for proteins analysis
- 20 March 2024
- Published by Elsevier in Microchemical Journal
- Vol. 200
Preparation of 3D pomegranate‐like quantum dot nanobeads and its application to highly sensitive detection of aflatoxin B1
- 20 March 2024
- Published by Elsevier in Microchemical Journal
- Vol. 200
Preparation of 3D pomegranate‐like quantum dot nanobeads and its application to highly sensitive detection of aflatoxin B1