Min Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Min Wang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Feiyang Cheng
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, China
4 shared publications - Gen Qiu
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, China
3 shared publications - Zhen Liu
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
3 shared publications - Chengcheng Wang
Instrumentation Technology and Economy Institute, Beijing, China
2 shared publications - Ke Sheng
School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, China
2 shared publications - Min Xie
City University of Hong Kong
2 shared publications
Latest Publications
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. PP (26879735) , 1-10
Adaptive Multidomain Disentangled Manifold Network for Fault Detection in Multimode Power Electronic Systems
Fault detection in power electronic systems is crucial for ensuring reliability and safety. A significant challenge lies in the scarcity of normal data across diverse operating modes, which leads existing data-driven methods to learn biased latent representations of normal behavior. This bias stems from their inability to establish intrinsic correlations between data-rich and data-scarce modes, leading to an unreliable normalcy baseline. To overcome this limitation, the Adaptive Multidomain Disentangled Manifold Network (AMDMN) is proposed, which couples disentangled representation learning with adaptive weighted manifold regularization. First, an adaptive weight-solving mechanism optimizes the manifold loss exclusively within this purified shared subspace, suppressing irrelevant condition-specific interference. Then, a weighted anomaly scoring mechanism is designed to evaluate the deviation of scarce target samples to construct a robust detection method. Furthermore, a theoretical framework is developed to assess the sensitivity of the anomaly score to weak faults and guarantee the convergence of the overall training process. Validated on a three-phase inverter platform, AMDMN achieved a F1-score of 0.9657 in target domain, significantly outperforming state-of-the-art methods, characterized by consistently high fault detection rates and low false alarm rates across diverse conditions.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. PP (26879735) , 1-10
Adaptive Multidomain Disentangled Manifold Network for Fault Detection in Multimode Power Electronic Systems
Fault detection in power electronic systems is crucial for ensuring reliability and safety. A significant challenge lies in the scarcity of normal data across diverse operating modes, which leads existing data-driven methods to learn biased latent representations of normal behavior. This bias stems from their inability to establish intrinsic correlations between data-rich and data-scarce modes, leading to an unreliable normalcy baseline. To overcome this limitation, the Adaptive Multidomain Disentangled Manifold Network (AMDMN) is proposed, which couples disentangled representation learning with adaptive weighted manifold regularization. First, an adaptive weight-solving mechanism optimizes the manifold loss exclusively within this purified shared subspace, suppressing irrelevant condition-specific interference. Then, a weighted anomaly scoring mechanism is designed to evaluate the deviation of scarce target samples to construct a robust detection method. Furthermore, a theoretical framework is developed to assess the sensitivity of the anomaly score to weak faults and guarantee the convergence of the overall training process. Validated on a three-phase inverter platform, AMDMN achieved a F1-score of 0.9657 in target domain, significantly outperforming state-of-the-art methods, characterized by consistently high fault detection rates and low false alarm rates across diverse conditions.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2888-2899
Anomaly Detection Based on Spatiotemporal Cascade Representation Learning for Critical Power Components of High Power Converters
Power conversion devices are widely used in aerospace, defense, modern industry, and transportation, etc., and their reliability is critical to the stable operation of high-power supply systems. With the rapid development of artificial intelligence, deep learning techniques have been increasingly applied to anomaly detection in power conversion devices due to their high detection efficiency. However, conventional approaches often fail to fully capture the spatiotemporal cascade features of increasingly complex systems, thereby limiting the effectiveness of feature extraction. To address this limitation, this article proposes a spatiotemporal cascade representation (STCR) model that enhances anomaly detection accuracy by jointly learning temporal and spatial features, as well as local and global dependencies. In the temporal domain, a self-attention mechanism is employed to model global dependencies, while local temporal information is extracted using a sliding-window approach. In the spatial domain, a spatial feature fusion matrix is designed to capture and integrate cross-component information. Theoretical analysis demonstrates the stability and effectiveness of the proposed STCR framework. Finally, experimental validation on a three-phase inverter system shows that the proposed method outperforms existing approaches, achieving at least a 4% improvement in fault detection rate.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2888-2899
Anomaly Detection Based on Spatiotemporal Cascade Representation Learning for Critical Power Components of High Power Converters
Power conversion devices are widely used in aerospace, defense, modern industry, and transportation, etc., and their reliability is critical to the stable operation of high-power supply systems. With the rapid development of artificial intelligence, deep learning techniques have been increasingly applied to anomaly detection in power conversion devices due to their high detection efficiency. However, conventional approaches often fail to fully capture the spatiotemporal cascade features of increasingly complex systems, thereby limiting the effectiveness of feature extraction. To address this limitation, this article proposes a spatiotemporal cascade representation (STCR) model that enhances anomaly detection accuracy by jointly learning temporal and spatial features, as well as local and global dependencies. In the temporal domain, a self-attention mechanism is employed to model global dependencies, while local temporal information is extracted using a sliding-window approach. In the spatial domain, a spatial feature fusion matrix is designed to capture and integrate cross-component information. Theoretical analysis demonstrates the stability and effectiveness of the proposed STCR framework. Finally, experimental validation on a three-phase inverter system shows that the proposed method outperforms existing approaches, achieving at least a 4% improvement in fault detection rate.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 7732-7742
Shared-Exclusive Disentangled Representation Learning With Channel Attention for Incipient Fault Detection in Multimode Power Inverter Systems
Inverter systems play a critical role in modern power conversion and energy management applications, where they often operate under diverse and complex modes. The presence of multiple operating modes leads to varying data distributions, posing significant challenges for accurate fault detection across different working scenarios. Existing methods struggle to disentangle mode-invariant and mode-specific features that effectively represent incipient faults, while also lacking selective attention across the disentangled feature spaces. To address this issue, this article proposes a shared and exclusive representation learning model (SERLM) for fault detection in multimode inverter systems. SERLM leverages shared and exclusive modules to extract mode-invariant and mode-specific features, respectively, and employs a novel multiscale regularized channel attention strategy to enhance feature fusion. In addition, two statistics are designed: one based on shared features to detect global anomalies across modes and another derived from reconstruction error to capture localized deviations. The effectiveness of feature extraction in SERLM is rigorously analyzed from a theoretical perspective. The proposed approach is validated through experiments on a power inverter system, demonstrating its superiority in detecting incipient faults under multiple modes, achieving a fault detection rate that is 6.25% higher than state-of-the-art methods.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 7732-7742
Shared-Exclusive Disentangled Representation Learning With Channel Attention for Incipient Fault Detection in Multimode Power Inverter Systems
Inverter systems play a critical role in modern power conversion and energy management applications, where they often operate under diverse and complex modes. The presence of multiple operating modes leads to varying data distributions, posing significant challenges for accurate fault detection across different working scenarios. Existing methods struggle to disentangle mode-invariant and mode-specific features that effectively represent incipient faults, while also lacking selective attention across the disentangled feature spaces. To address this issue, this article proposes a shared and exclusive representation learning model (SERLM) for fault detection in multimode inverter systems. SERLM leverages shared and exclusive modules to extract mode-invariant and mode-specific features, respectively, and employs a novel multiscale regularized channel attention strategy to enhance feature fusion. In addition, two statistics are designed: one based on shared features to detect global anomalies across modes and another derived from reconstruction error to capture localized deviations. The effectiveness of feature extraction in SERLM is rigorously analyzed from a theoretical perspective. The proposed approach is validated through experiments on a power inverter system, demonstrating its superiority in detecting incipient faults under multiple modes, achieving a fault detection rate that is 6.25% higher than state-of-the-art methods.
- Open Access
- 1 September 2025
- Published by KEAI Publishing in Journal of Automation and Intelligence
- Vol. 4 (3) , 217-226
Densely-connected Decoder Transformer for unsupervised anomaly detection of power electronic systems
- 1 September 2025
- Published by KEAI Publishing in Journal of Automation and Intelligence
- Vol. 4 (3) , 217-226
Open AccessDensely-connected Decoder Transformer for unsupervised anomaly detection of power electronic systems
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 55 (7) , 5054-5068
Optimal Sequential-Parallel Test Strategy Generation Method for Complex Systems
One of the core tasks of design for testability (DFT) is to generate an optimal test strategy based on the test mode, to isolate faults quickly and accurately. There are currently two modes: 1) sequential test mode (STM) and 2) parallel test mode (PTM). For complex systems, limited testing resources are difficult to meet parallel test conditions, so STM is mostly used. The multisignal flow graph is a widely used model for generating optimal sequential test strategy (STS) in DFT. However, this STM-based model overlooks the possibility of conducting some tests in parallel, resulting in lengthy test time and greatly affecting the reliability and security of the systems. To solve this problem, an optimal sequential-parallel test strategy (SPTS) generation method is proposed. First, a new test mode of global sequential testing and local parallel testing is proposed to generalize the original model. Second, to overcome the combinatorial explosion caused by the new model, we approximate the discrete model to continuous and derive a probability heuristic function. Then, a neural network-intelligent algorithm structure is established to simplify the complex recursion of the heuristic function. Finally, this heuristic function is used to guide the generation of SPTS, which has a shorter test time than STS. Simulation results show that the reduction in time is related to the type and number of locally parallel tests, and reaches 39.5% in a real case.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Systems, Man, and Cybernetics: Systems
- Vol. 55 (7) , 5054-5068
Optimal Sequential-Parallel Test Strategy Generation Method for Complex Systems
One of the core tasks of design for testability (DFT) is to generate an optimal test strategy based on the test mode, to isolate faults quickly and accurately. There are currently two modes: 1) sequential test mode (STM) and 2) parallel test mode (PTM). For complex systems, limited testing resources are difficult to meet parallel test conditions, so STM is mostly used. The multisignal flow graph is a widely used model for generating optimal sequential test strategy (STS) in DFT. However, this STM-based model overlooks the possibility of conducting some tests in parallel, resulting in lengthy test time and greatly affecting the reliability and security of the systems. To solve this problem, an optimal sequential-parallel test strategy (SPTS) generation method is proposed. First, a new test mode of global sequential testing and local parallel testing is proposed to generalize the original model. Second, to overcome the combinatorial explosion caused by the new model, we approximate the discrete model to continuous and derive a probability heuristic function. Then, a neural network-intelligent algorithm structure is established to simplify the complex recursion of the heuristic function. Finally, this heuristic function is used to guide the generation of SPTS, which has a shorter test time than STS. Simulation results show that the reduction in time is related to the type and number of locally parallel tests, and reaches 39.5% in a real case.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Incipient Fault Detection Based on Multiscale Time Series Feature Extraction
As the rapid development of industrial manufacturing with increasing level of automation, the reliability and performance requirements of systems have been receiving more and more attention. The occurrence of fault usually leads to substantial financial losses and even monstrous disasters in production process. However, incipient fault detection in manufacturing process is usually limited by two aspects: (1) Lack of fault data; (2) Hidden abnormal features in time series. Therefore, an incipient fault detection method which is called autoencoder multi-scale temporal convolutional network (AMTCN) based on multi–scale time series feature extraction is proposed in this paper. By autonomously learning distinctive features from the normal samples, the AMTCN circumvents the subjectivity and time-consuming process of manual feature extraction. Moreover, the AMTCN effectively captures long-term dependencies in the temporal dimension while extracting multi-scale information in the feature space through the integration of autoencoder structure and multi-scale temporal convolutional layers. Ultimately, a maintenance platform of industrial instruments and meters is constructed and the process data from the platform is utilized to demonstrate the effectiveness and efficiency of the proposed approach for incipient fault detection.
- 21 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Incipient Fault Detection Based on Multiscale Time Series Feature Extraction
As the rapid development of industrial manufacturing with increasing level of automation, the reliability and performance requirements of systems have been receiving more and more attention. The occurrence of fault usually leads to substantial financial losses and even monstrous disasters in production process. However, incipient fault detection in manufacturing process is usually limited by two aspects: (1) Lack of fault data; (2) Hidden abnormal features in time series. Therefore, an incipient fault detection method which is called autoencoder multi-scale temporal convolutional network (AMTCN) based on multi–scale time series feature extraction is proposed in this paper. By autonomously learning distinctive features from the normal samples, the AMTCN circumvents the subjectivity and time-consuming process of manual feature extraction. Moreover, the AMTCN effectively captures long-term dependencies in the temporal dimension while extracting multi-scale information in the feature space through the integration of autoencoder structure and multi-scale temporal convolutional layers. Ultimately, a maintenance platform of industrial instruments and meters is constructed and the process data from the platform is utilized to demonstrate the effectiveness and efficiency of the proposed approach for incipient fault detection.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 74 (7) , 10321-10331
A Micromesh Multi-Scaled Features Extraction Network for Li-Ion Batteries SOH Estimation
The great progress and wide application of electronic products and electric vehicles have entailed more stringent requirements for the reliability of lithium-ion batteries. The State of Health (SOH) serves as a significant indicator for evaluating the condition of such batteries. However existing methods are lack of refined modeling for sequences and unable to make precise estimation for SOH. In this paper, a micromesh multi-scaled features extraction network (MMFEN) is proposed for accurately estimating SOH. A refined representation block is developed for heterogeneous elaborate feature extraction. Then, a multi-head convolution attention block is constructed to capture multi-scaled efficient state information. To demonstrate the superiority of MMFEN, experiments are conducted on the NASA and CALCE data published online and a real-world electric vehicles (EVs) data set which is collected from existing battery management systems. Comparing with traditional methods, MMFEN achieves remarkable performance with average root mean square error of 1.21% and mean absolute percentage error of 0.99% on NASA samples, 2.78% and 2.71% on CALCE dataset, while 2.39% and 2.08% on EVs data set, respectively.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 74 (7) , 10321-10331
A Micromesh Multi-Scaled Features Extraction Network for Li-Ion Batteries SOH Estimation
The great progress and wide application of electronic products and electric vehicles have entailed more stringent requirements for the reliability of lithium-ion batteries. The State of Health (SOH) serves as a significant indicator for evaluating the condition of such batteries. However existing methods are lack of refined modeling for sequences and unable to make precise estimation for SOH. In this paper, a micromesh multi-scaled features extraction network (MMFEN) is proposed for accurately estimating SOH. A refined representation block is developed for heterogeneous elaborate feature extraction. Then, a multi-head convolution attention block is constructed to capture multi-scaled efficient state information. To demonstrate the superiority of MMFEN, experiments are conducted on the NASA and CALCE data published online and a real-world electric vehicles (EVs) data set which is collected from existing battery management systems. Comparing with traditional methods, MMFEN achieves remarkable performance with average root mean square error of 1.21% and mean absolute percentage error of 0.99% on NASA samples, 2.78% and 2.71% on CALCE dataset, while 2.39% and 2.08% on EVs data set, respectively.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3543-3552
Intensive Multiorder Feature Extraction for Incipient Fault Detection of Inverter System
Inverter systems play a crucial role in aerospace, defense, transportation, modern industry, and power systems, leading to extensive efforts from scholars and engineers in fault diagnosis. Data-based methods are widely utilized with the accessible history data instead of complex math modeling for this issue but they are incompetent for obstinate incipient fault. Therefore, this article proposes an intensive multiorder feature extractor (IMFE) for the incipient fault detection of inverter system, with intensively extracting deep statistical features and reducing harmful perturbations. First, a dense structure with short paths between nonadjacent layers is adopted for multiorder knowledge reutilization. Then, the acquired features are refined and the low-quality information is discarded. In addition, the effectiveness of IMFE is demonstrated through rigorous mathematical derivation with sensitivity and complexity analysis. Finally, a three-phase inverter system platform based on current and voltage dual control is established to verify the superiority of the proposed method. Experimental results show that the proposed approach significantly improves fault detection performance, achieving a 3.1% higher fault detection rate compared to existing state-of-the-art methods.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 3543-3552
Intensive Multiorder Feature Extraction for Incipient Fault Detection of Inverter System
Inverter systems play a crucial role in aerospace, defense, transportation, modern industry, and power systems, leading to extensive efforts from scholars and engineers in fault diagnosis. Data-based methods are widely utilized with the accessible history data instead of complex math modeling for this issue but they are incompetent for obstinate incipient fault. Therefore, this article proposes an intensive multiorder feature extractor (IMFE) for the incipient fault detection of inverter system, with intensively extracting deep statistical features and reducing harmful perturbations. First, a dense structure with short paths between nonadjacent layers is adopted for multiorder knowledge reutilization. Then, the acquired features are refined and the low-quality information is discarded. In addition, the effectiveness of IMFE is demonstrated through rigorous mathematical derivation with sensitivity and complexity analysis. Finally, a three-phase inverter system platform based on current and voltage dual control is established to verify the superiority of the proposed method. Experimental results show that the proposed approach significantly improves fault detection performance, achieving a 3.1% higher fault detection rate compared to existing state-of-the-art methods.