Yuki Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuki Saito has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Harukazu Tohyama
Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
4 shared publicationsMina Samukawa
Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
4 shared publicationsRyo Takeda
Faculty of Engineering, Hokkaido University, Sapporo, Japan
4 shared publicationsSatoshi Osuka
Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
4 shared publicationsShigeru Tadano
Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
4 shared publicationsTomoya Ishida
Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
4 shared publications
Latest Publications
- Open Access
Evaluation of Lower-Limb Kinematics during Timed Up and Go (TUG) Test in Subjects with Locomotive Syndrome (LS) Using Wearable Gait Sensors (H-Gait System)
Few studies have dealt with lower-limb kinematics during the timed up and go (TUG) test in subjects with locomotive syndrome (LS). This study aimed to evaluate the characteristics of lower-limb kinematics during the TUG test in subjects with LS using the wearable sensor-based H-Gait system. A total of 140 participants were divided into the non-LS (n = 28), the LS-stage 1 (n = 78), and LS-stage 2 (n = 34) groups based on the LS risk test. Compared with the non-LS group, the LS-stage 1 and LS-stage 2 groups showed significantly smaller angular velocity of hip and knee extension during the sit-to-stand phase. The LS-stage 2 group showed significantly smaller peak angles of hip extension and flexion during the walking-out phase compared to the non-LS group. These findings indicate that the evaluation of the lower-limb kinematics during the TUG test using the H-Gait system is highly sensitive to detect LS, compared with the evaluation of the lower-limb kinematics when simply walking.
Open AccessEvaluation of Lower-Limb Kinematics during Timed Up and Go (TUG) Test in Subjects with Locomotive Syndrome (LS) Using Wearable Gait Sensors (H-Gait System)
Few studies have dealt with lower-limb kinematics during the timed up and go (TUG) test in subjects with locomotive syndrome (LS). This study aimed to evaluate the characteristics of lower-limb kinematics during the TUG test in subjects with LS using the wearable sensor-based H-Gait system. A total of 140 participants were divided into the non-LS (n = 28), the LS-stage 1 (n = 78), and LS-stage 2 (n = 34) groups based on the LS risk test. Compared with the non-LS group, the LS-stage 1 and LS-stage 2 groups showed significantly smaller angular velocity of hip and knee extension during the sit-to-stand phase. The LS-stage 2 group showed significantly smaller peak angles of hip extension and flexion during the walking-out phase compared to the non-LS group. These findings indicate that the evaluation of the lower-limb kinematics during the TUG test using the H-Gait system is highly sensitive to detect LS, compared with the evaluation of the lower-limb kinematics when simply walking.
- Open Access
- 14 May 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-8
Evaluation of gait characteristics in subjects with locomotive syndrome using wearable gait sensors
Background: Individuals with locomotive syndrome (LS) require nursing care services owing to problems with locomotion and the musculoskeletal system. Individuals with LS generally have a reduced walking speed compared with those without LS. However, differences in lower-limb kinematics and gait between individuals with and without LS are not fully understood. This study aimed to clarify the characteristics of the gait kinematics of individuals with LS using wearable sensors. Methods: We assessed 125 participants (mean age 73.0 ± 6.7 years) who used a public health promotion facility. Based on the 25-question Geriatric Locomotive Function Scale (GLFS-25), these participants were grouped into the non-LS (GLFS-25 < 7), LS-stage 1 (GLFS-25 7–16), and LS-stage 2 (GLFS-25 ≥ 16) groups (larger GLFS-25 scores indicate worse locomotive ability). Spatiotemporal parameters and lower-limb kinematics during the 10-m walk test were analyzed by the “H-Gait system”, which is a motion analysis system that was developed by the authors and is based on seven inertial sensors. The peak joint angles during the stance and swing phases, as well as the gait speed, cadence, and step length were compared among all groups. Results: There were 69 participants in the non-LS group, 33 in the LS-stage 1 group, and 23 in the LS-stage 2 group. Compared with the non-LS group, the LS-stage 2 group showed significantly smaller peak angles of hip extension (9.5 ± 5.3° vs 4.2 ± 8.2°, P = 0.002), hip flexion (34.2 ± 8.8° vs 28.5 ± 9.5°, P = 0.026), and knee flexion (65.2 ± 18.7° vs 50.6 ± 18.5°, P = 0.005). The LS-stage 1 and LS-stage 2 groups had a significantly slower mean gait speed than the non-LS group (non-LS: 1.3 ± 0.2 m/s, LS-stage 1: 1.2 ± 0.2 m/s, LS-stage 2: 1.1 ± 0.2 m/s, P < 0.001). Conclusions: The LS-stage 2 group showed significantly different lower-limb kinematics compared with the non-LS group, including smaller peak angles of hip extension, hip flexion, and knee flexion. It would be useful to assess and improve these small peak joint angles during gait for individuals classified as LS-stage 2.
- 14 May 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-8
Open AccessEvaluation of gait characteristics in subjects with locomotive syndrome using wearable gait sensors
Background: Individuals with locomotive syndrome (LS) require nursing care services owing to problems with locomotion and the musculoskeletal system. Individuals with LS generally have a reduced walking speed compared with those without LS. However, differences in lower-limb kinematics and gait between individuals with and without LS are not fully understood. This study aimed to clarify the characteristics of the gait kinematics of individuals with LS using wearable sensors. Methods: We assessed 125 participants (mean age 73.0 ± 6.7 years) who used a public health promotion facility. Based on the 25-question Geriatric Locomotive Function Scale (GLFS-25), these participants were grouped into the non-LS (GLFS-25 < 7), LS-stage 1 (GLFS-25 7–16), and LS-stage 2 (GLFS-25 ≥ 16) groups (larger GLFS-25 scores indicate worse locomotive ability). Spatiotemporal parameters and lower-limb kinematics during the 10-m walk test were analyzed by the “H-Gait system”, which is a motion analysis system that was developed by the authors and is based on seven inertial sensors. The peak joint angles during the stance and swing phases, as well as the gait speed, cadence, and step length were compared among all groups. Results: There were 69 participants in the non-LS group, 33 in the LS-stage 1 group, and 23 in the LS-stage 2 group. Compared with the non-LS group, the LS-stage 2 group showed significantly smaller peak angles of hip extension (9.5 ± 5.3° vs 4.2 ± 8.2°, P = 0.002), hip flexion (34.2 ± 8.8° vs 28.5 ± 9.5°, P = 0.026), and knee flexion (65.2 ± 18.7° vs 50.6 ± 18.5°, P = 0.005). The LS-stage 1 and LS-stage 2 groups had a significantly slower mean gait speed than the non-LS group (non-LS: 1.3 ± 0.2 m/s, LS-stage 1: 1.2 ± 0.2 m/s, LS-stage 2: 1.1 ± 0.2 m/s, P < 0.001). Conclusions: The LS-stage 2 group showed significantly different lower-limb kinematics compared with the non-LS group, including smaller peak angles of hip extension, hip flexion, and knee flexion. It would be useful to assess and improve these small peak joint angles during gait for individuals classified as LS-stage 2.
- Open Access
- 12 January 2022
- Published by Springer Nature in Research Square
Evaluation of Gait Characteristics in Subjects With Locomotive Syndrome Using the Wearable Gait Sensors
Background: Locomotive syndrome (LS) is a condition where a person requires nursing care services due to problems with locomotive abilities and musculoskeletal systems. Individuals with LS have a reduced walking speed compared to those without LS. However, differences in lower-limb kinematics and during walking between individuals with and without LS are not fully understood. The purpose of this study is to clarify the characteristics of gait kinematics using wearable sensors for individuals with LS.Methods: We assessed 125 people aged 65 years and older who utilized a public health promotion facility. The participants were grouped into Non-LS, LS-stage 1, LS-stage 2 (large number indicate worse locomotive ability) based on 25-question Geriatric Locomotive Function Scale (GLFS-25). Spatiotemporal parameters and lower-limb kinematics during 10-m walking test were analyzed by 7-inertia-sensors based motion analysis system. Peak joint angles during stance and swing phase as well as gait speed, cadence and step length were compared among all groups.Results: The number of each LS stage was 69, 33, 23 for Non-LS, LS-stage 1, LS-stage 2, respectively. LS-stage2 group showed significantly smaller peak hip extension angle, hip flexion angle and knee flexion angle than Non-LS group (hip extension: Non-LS: 9.5 ± 5.3°, LS-stage 2: 4.2 ± 8.2°, P = 0.002; hip flexion: No-LS: 34.2 ± 8.8°, LS-stage 2: 28.5 ± 9.5°, P = 0.026; knee flexion: Non-LS: 65.2 ± 18.7°, LS-stage 2: 50.6 ± 18.5°, P = 0.005). LS-stage 1 and LS-stage 2 groups showed significantly slower gait speed than Non-LS group (Non-LS 1.3 ± 0.2 m/s, LS-stage1 1.2 ± 0.2 m/s, LS-stage2 1.1 ± 0.2 m/s, P < 0.001).Conclusions: LS-stage2 group showed significantly different lower-limb kinematics compared with Non-LS group including smaller hip extension, hip flexion and knee flexion. The intervention based on these kinematic characteristics measured by wearable sensors would be useful to improve the locomotive ability for individuals classified LS-stage2.
- 12 January 2022
- Published by Springer Nature in Research Square
Open AccessEvaluation of Gait Characteristics in Subjects With Locomotive Syndrome Using the Wearable Gait Sensors
Background: Locomotive syndrome (LS) is a condition where a person requires nursing care services due to problems with locomotive abilities and musculoskeletal systems. Individuals with LS have a reduced walking speed compared to those without LS. However, differences in lower-limb kinematics and during walking between individuals with and without LS are not fully understood. The purpose of this study is to clarify the characteristics of gait kinematics using wearable sensors for individuals with LS.Methods: We assessed 125 people aged 65 years and older who utilized a public health promotion facility. The participants were grouped into Non-LS, LS-stage 1, LS-stage 2 (large number indicate worse locomotive ability) based on 25-question Geriatric Locomotive Function Scale (GLFS-25). Spatiotemporal parameters and lower-limb kinematics during 10-m walking test were analyzed by 7-inertia-sensors based motion analysis system. Peak joint angles during stance and swing phase as well as gait speed, cadence and step length were compared among all groups.Results: The number of each LS stage was 69, 33, 23 for Non-LS, LS-stage 1, LS-stage 2, respectively. LS-stage2 group showed significantly smaller peak hip extension angle, hip flexion angle and knee flexion angle than Non-LS group (hip extension: Non-LS: 9.5 ± 5.3°, LS-stage 2: 4.2 ± 8.2°, P = 0.002; hip flexion: No-LS: 34.2 ± 8.8°, LS-stage 2: 28.5 ± 9.5°, P = 0.026; knee flexion: Non-LS: 65.2 ± 18.7°, LS-stage 2: 50.6 ± 18.5°, P = 0.005). LS-stage 1 and LS-stage 2 groups showed significantly slower gait speed than Non-LS group (Non-LS 1.3 ± 0.2 m/s, LS-stage1 1.2 ± 0.2 m/s, LS-stage2 1.1 ± 0.2 m/s, P < 0.001).Conclusions: LS-stage2 group showed significantly different lower-limb kinematics compared with Non-LS group including smaller hip extension, hip flexion and knee flexion. The intervention based on these kinematic characteristics measured by wearable sensors would be useful to improve the locomotive ability for individuals classified LS-stage2.
- Open Access
Analysis of 3-D Kinematics Using H-Gait System during Walking on a Lower Body Positive Pressure Treadmill
Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.
Open AccessAnalysis of 3-D Kinematics Using H-Gait System during Walking on a Lower Body Positive Pressure Treadmill
Recently, treadmills equipped with a lower-body positive-pressure (LBPP) device have been developed to provide precise body weight support (BWS) during walking. Since lower limbs are covered in a waist-high chamber of an LBPP treadmill, a conventional motion analysis using an optical method is impossible to evaluate gait kinematics on LBPP. We have developed a wearable-sensor-based three-dimensional motion analysis system, H-Gait. The purpose of the present study was to investigate the effects of BWS by a LBPP treadmill on gait kinematics using an H-Gait system. Twenty-five healthy subjects walked at 2.5 km/h on a LBPP treadmill under the following three conditions: (1) 0%BWS, (2) 25%BWS and (3) 50%BWS conditions. Acceleration and angular velocity from seven wearable sensors were used to analyze lower limb kinematics during walking. BWS significantly decreased peak angles of hip adduction, knee adduction and ankle dorsiflexion. In particular, the peak knee adduction angle at the 50%BWS significantly decreased compared to at the 25%BWS (p = 0.012) or 0%BWS (p < 0.001). The present study showed that H-Gait system can detect the changes in gait kinematics in response to BWS by a LBPP treadmill and provided a useful clinical application of the H-Gait system to walking exercises.
- Open Access
- 8 January 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-9
Effects of unweighting on gait kinematics during walking on a lower-body positive-pressure treadmill in patients with hip osteoarthritis
Background: Hip osteoarthritis (OA) is a musculoskeletal condition that makes walking difficult due to pain induced by weight-bearing activities. Treadmills that support the body weight (BW) reduce the load on the lower limbs, and those equipped with a lower-body positive-pressure (LBPP) device, developed as a new method for unweighting, significantly reduce pain in patients with knee OA. However, the effects of unweighting on gait kinematics remain unclear in patients with hip OA. Therefore, we investigated the effects of unweighting on kinematics in patients with hip OA during walking on a treadmill equipped with an LBPP device.Methods: A total of 15 women with hip OA and 15 age-matched female controls wore a three-dimensional (3-D) motion analysis system and walked at a self-selected speed on the LBPP treadmill. Data regarding self-reported hip pain using a numeric rating scale (NRS) in which the scores 0 and 10 represented no pain and the worst pain, respectively, under three different BW conditions (100, 75, and 50%) were collected. Moreover, 3-D peak joint angles during gait under each condition were calculated and compared.Results: In the hip OA group, the NRS pain scores at 50 and 75% BW conditions significantly decreased compared with that at 100% BW condition (50%,P = 0.002; 75%,P = 0.026), and the peak hip extension angle decreased compared with that in the healthy controls (P = 0.044). In both groups, unweighting significantly decreased the peak hip (P < 0.001) and knee (P < 0.001) flexion angles and increased the peak ankle plantar flexion angle (P < 0.001) during walking.Conclusions: Unweighting by the LBPP treadmill decreased pain in the hip OA group but did not drastically alter the gait kinematics compared with that in the control group. Therefore, regarding the use of the LBPP treadmill for patients with hip OA, clinicians should consider the benefits of pain reduction rather than the kinematic changes.
- 8 January 2021
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-9
Open AccessEffects of unweighting on gait kinematics during walking on a lower-body positive-pressure treadmill in patients with hip osteoarthritis
Background: Hip osteoarthritis (OA) is a musculoskeletal condition that makes walking difficult due to pain induced by weight-bearing activities. Treadmills that support the body weight (BW) reduce the load on the lower limbs, and those equipped with a lower-body positive-pressure (LBPP) device, developed as a new method for unweighting, significantly reduce pain in patients with knee OA. However, the effects of unweighting on gait kinematics remain unclear in patients with hip OA. Therefore, we investigated the effects of unweighting on kinematics in patients with hip OA during walking on a treadmill equipped with an LBPP device.Methods: A total of 15 women with hip OA and 15 age-matched female controls wore a three-dimensional (3-D) motion analysis system and walked at a self-selected speed on the LBPP treadmill. Data regarding self-reported hip pain using a numeric rating scale (NRS) in which the scores 0 and 10 represented no pain and the worst pain, respectively, under three different BW conditions (100, 75, and 50%) were collected. Moreover, 3-D peak joint angles during gait under each condition were calculated and compared.Results: In the hip OA group, the NRS pain scores at 50 and 75% BW conditions significantly decreased compared with that at 100% BW condition (50%,P = 0.002; 75%,P = 0.026), and the peak hip extension angle decreased compared with that in the healthy controls (P = 0.044). In both groups, unweighting significantly decreased the peak hip (P < 0.001) and knee (P < 0.001) flexion angles and increased the peak ankle plantar flexion angle (P < 0.001) during walking.Conclusions: Unweighting by the LBPP treadmill decreased pain in the hip OA group but did not drastically alter the gait kinematics compared with that in the control group. Therefore, regarding the use of the LBPP treadmill for patients with hip OA, clinicians should consider the benefits of pain reduction rather than the kinematic changes.
- Open Access
- 7 January 2021
- Published by Springer Nature in Research Square
Effects of Unweighting on Gait Kinematics During Walking on a Lower-Body Positive-Pressure Treadmill in Patients with Hip Osteoarthritis
Background: Hip osteoarthritis (OA) is a musculoskeletal condition that makes walking difficult due to pain induced by weight-bearing activities. Treadmills that support the body weight (BW) reduce the load on the lower limbs, and those equipped with a lower-body positive-pressure (LBPP) device, developed as a new method for unweighting, significantly reduce pain in patients with knee OA. However, the effects of unweighting on gait kinematics remain unclear in patients with hip OA. Therefore, we investigated the effects of unweighting on kinematics in patients with hip OA during walking on a treadmill equipped with an LBPP device. Methods: A total of 15 women with hip OA and 15 age-matched female controls wore a three-dimensional (3-D) motion analysis system and walked at a self-selected speed on the LBPP treadmill. Data regarding self-reported hip pain using a numeric rating scale (NRS) in which the scores 0 and 10 represented no pain and the worst pain, respectively, under three different BW conditions (100%, 75%, and 50%) were collected. Moreover, 3-D peak joint angles during gait under each condition were calculated and compared. Results: In the hip OA group, the NRS pain scores at 50% and 75% BW conditions significantly decreased compared with that at 100% BW condition (50%, P=0.002; 75%, P=0.026), and the peak hip extension angle decreased compared with that in the healthy controls (P=0.044). In both groups, unweighting significantly decreased the peak hip (PConclusions: Unweighting by the LBPP treadmill decreased pain in the hip OA group but did not drastically alter the gait kinematics compared with that in the control group. Therefore, regarding the use of the LBPP treadmill for patients with hip OA, clinicians should consider the benefits of pain reduction rather than the kinematic changes.
- 7 January 2021
- Published by Springer Nature in Research Square
Open AccessEffects of Unweighting on Gait Kinematics During Walking on a Lower-Body Positive-Pressure Treadmill in Patients with Hip Osteoarthritis
Background: Hip osteoarthritis (OA) is a musculoskeletal condition that makes walking difficult due to pain induced by weight-bearing activities. Treadmills that support the body weight (BW) reduce the load on the lower limbs, and those equipped with a lower-body positive-pressure (LBPP) device, developed as a new method for unweighting, significantly reduce pain in patients with knee OA. However, the effects of unweighting on gait kinematics remain unclear in patients with hip OA. Therefore, we investigated the effects of unweighting on kinematics in patients with hip OA during walking on a treadmill equipped with an LBPP device. Methods: A total of 15 women with hip OA and 15 age-matched female controls wore a three-dimensional (3-D) motion analysis system and walked at a self-selected speed on the LBPP treadmill. Data regarding self-reported hip pain using a numeric rating scale (NRS) in which the scores 0 and 10 represented no pain and the worst pain, respectively, under three different BW conditions (100%, 75%, and 50%) were collected. Moreover, 3-D peak joint angles during gait under each condition were calculated and compared. Results: In the hip OA group, the NRS pain scores at 50% and 75% BW conditions significantly decreased compared with that at 100% BW condition (50%, P=0.002; 75%, P=0.026), and the peak hip extension angle decreased compared with that in the healthy controls (P=0.044). In both groups, unweighting significantly decreased the peak hip (PConclusions: Unweighting by the LBPP treadmill decreased pain in the hip OA group but did not drastically alter the gait kinematics compared with that in the control group. Therefore, regarding the use of the LBPP treadmill for patients with hip OA, clinicians should consider the benefits of pain reduction rather than the kinematic changes.