Haotian Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haotian Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chao Wang
Engineering Research Center of Intelligent Theranostics Technology and Instruments, Ministry of Education, School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing, 211166, China
1 shared publication - Fan Meng
Department of Anesthesiology, Sir Run Run Hospital Affiliated to Nanjing Medical University 2 , Longmian Avenue 109, Jiangning District, Nanjing 211166, People’s Republic of China
1 shared publication - Fengxue Wu
Department of Biomedical Engineering, School of Biomedical Engineering and Informatics, Nanjing Medical University 1 , Longmian Avenue 101, Jiangning District, Nanjing 211166, People’s Republic of China
1 shared publication - Shaochen Wang
Department of Biomedical Engineering, School of Biomedical Engineering and Informatics, Nanjing Medical University 1 , Longmian Avenue 101, Jiangning District, Nanjing 211166, People’s Republic of China
1 shared publication - X. H. He
Department of Biomedical Engineering, School of Biomedical Engineering and Informatics, Nanjing Medical University 1 , Longmian Avenue 101, Jiangning District, Nanjing 211166, People’s Republic of China
1 shared publication - Xiaonan Wang
Department of Biomedical Engineering, School of Biomedical Engineering and Informatics, Nanjing Medical University 1 , Longmian Avenue 101, Jiangning District, Nanjing 211166, People’s Republic of China
1 shared publication
Latest Publications
- Open Access
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Research on accurate pipetting complementation model for high-throughput molecular detection platform
The incidence of infectious diseases has risen in recent years, leading to a significant surge in the demand for medical molecular detection. High-throughput molecular detection platforms play a crucial role in facilitating rapid and efficient molecular detection. Among the various techniques employed in high-throughput molecular detection, microliquid transfer stands out as one of the most frequently utilized methods. However, ensuring the accuracy of liquid transfer poses a challenge due to variations in the physical and chemical properties of different samples and reagents. In this study, a pipetting complementation model was developed specifically for the serum, paraffin oil, and throat swabs. The aim was to enhance the transfer accuracy of diverse liquids in the context of high-throughput molecular detection, ultimately ensuring detection reliability and stability. The experimental findings revealed notable improvements in pipetting accuracy after compensating for the three liquids. In particular, the pipetting error rates decreased by 52.5, 96, and 71.4% for serum, paraffin oil, and throat swabs, respectively. These results underscore the model’s effectiveness in providing reliable support for the precise transfer of liquids on the high-throughput molecular detection platform.
- 1 February 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (2)
Open AccessResearch on accurate pipetting complementation model for high-throughput molecular detection platform
The incidence of infectious diseases has risen in recent years, leading to a significant surge in the demand for medical molecular detection. High-throughput molecular detection platforms play a crucial role in facilitating rapid and efficient molecular detection. Among the various techniques employed in high-throughput molecular detection, microliquid transfer stands out as one of the most frequently utilized methods. However, ensuring the accuracy of liquid transfer poses a challenge due to variations in the physical and chemical properties of different samples and reagents. In this study, a pipetting complementation model was developed specifically for the serum, paraffin oil, and throat swabs. The aim was to enhance the transfer accuracy of diverse liquids in the context of high-throughput molecular detection, ultimately ensuring detection reliability and stability. The experimental findings revealed notable improvements in pipetting accuracy after compensating for the three liquids. In particular, the pipetting error rates decreased by 52.5, 96, and 71.4% for serum, paraffin oil, and throat swabs, respectively. These results underscore the model’s effectiveness in providing reliable support for the precise transfer of liquids on the high-throughput molecular detection platform.