SWSijia Wu

Sijia Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sijia Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real-Time Diagnosis of Stator Winding Faults in PMSM Based on Residual CNN With Channel Attention Mechanism

    by Wencai Lv, Shuai Xu, Taoning Zhu, Liang Chen, Sijia Wu, Hong Xie, Guangtong Ma

    The fault detection and identification are essential for permanent magnet synchronous motors (PMSMs) to guarantee the reliable and continuous operation. As the primary energy conversion component, the stator winding integrity critically determines operational reliability. Various fault types exhibit distinct degradation patterns, requiring not only detection but precise identification for targeted maintenance. Existing data-driven fault diagnosis strategies are mostly limited to single-fault detection and offline operation. In this study, an online stator winding fault diagnosis method for PMSM is proposed based on a residual convolutional neural network with a squeezing excitation channel attention mechanism (SE-ResCNN). This method is capable of extracting both the global and local features by combining the residual branches with the CNN branches. Besides, a squeezing excitation attention mechanism is employed to realize the cross-branch channel fusion, thereby enhancing the diagnostic accuracy. Afterward, leveraging the RK3588 edge device and model conversion and migration techniques, the designed network enables efficient edge deployment while maintaining diagnostic accuracy and real-time processing speed. Finally, the proposed online diagnosis method is validated through an experimental platform of the PMSM drives.


  • Real-Time Diagnosis of Multiple Open-Circuit Faults in ANPC Inverters Based on Lightweight Deployment of Edge 2D-CNN

    by Guangtong Ma, Chunxing Yao, Shuai Xu, Guanzhou Ren, Zhenyao Sun, Sijia Wu

    Multiple open-circuit (OC) faults have severely deteriorated the reliable operation of active neutral-point-clamped (ANPC) inverters. To achieve fast and accurate detection for multiple OC faults of three-level ANPC (3L-ANPC) inverter, this article deploys a lightweight convolutional neural network (CNN) into an edge computation board. Specifically, the proposed online diagnosis includes offline training and online deployment. During the offline training, a multisource information fusion is devised to promote the effective feature extraction, thereby enhancing the predictive accuracy of the designed CNN. Furthermore, a specific optimization framework is utilized to simplify the offline training process. For online deployment, the lightweight design of the trained CNN is realized by employing the TensorRT to reduce the computation cost and accelerate the diagnostic speed. Comparative studies are conducted to verify the advantages and the generalization ability of the designed CNN. Finally, the feasibility of the proposed edge-based diagnosis strategy is experimentally verified through the platform of the permanent magnet synchronous motor drives fed by 3L-ANPC inverter.


  • Weighting Factors Autotuning of FCS-MPC for Hybrid ANPC Inverter in PMSM Drives Based on Deep Residual Networks

    by Shuai Xu, Chunxing Yao, Guanzhou Ren, Zhenyao Sun, Sijia Wu, Guangtong Ma

    Hybrid active neutral-point-clamped (HANPC) inverters have been recently considered as an attractive solution for high-power applications, while their control with multiple objectives remains quite complicated. The model predictive control (MPC) is an optimal control technique for multilevel inverters due to its powerful ability to handle the multiobjective optimization and nonlinear constrains. However, the tuning of weighting factors (WFs) in MPC is quite challenging and requires additional computational resources. For this motivation, this article proposes a deep residual network optimization approach for the dynamical WFs tuning of the finite control set (FCS) MPC in the HANPC inverters. The proposed method utilizes the residual connection to avoid the problem of gradient vanishing, so as to improve the predictive accuracy. To realize the dynamic adjustment of WFs, a look-up table is formulated with the predicted WFs, then this look-up table is integrated into the FCS-MPC. Consequently, the proposed method occupies less logic resources in the MPC algorithm, providing the desired behavior with fast dynamic response. Comparative studies are presented to evaluate the training and prediction performance of the networks. Finally, the experimental validations are conducted on a platform of HANPC-inverter-fed permanent magnet synchronous motor drive.


  • Current Sensor Fault Detection and Identification for PMSM Drives Using Multichannel Global Maximum Pooling CNN

    by Sijia Wu, Guangtong Ma, Chunxing Yao, Zhenyao Sun, Shuai Xu

    The permanent magnet synchronous motors (PMSM) have been widely used in motor drive applications. In the closed-loop control system, the current sensors play an essential role, which are highly prone to failures due to high electron-thermal pressure and abnormal vibration. In this paper, an efficient current sensor fault detection and identification (FDI) method is proposed for the PMSM drives based on a modified one-dimension convolutional neural network (1D-CNN). In this method, the multi-channel input and global maximum pooling (GMP) layer are dedicatedly designed to achieve a higher diagnostic accuracy. Besides, the number of network parameters is significantly decreased, thereby reducing the training time. Moreover, the data normalization is adopted to enhance the training performance and generalization ability of the proposed network. The effectiveness and generalization of the proposed FDI method is validated via the experimental data obtained on a three-level ANPC-inverter-fed PMSM drive platform.


  • Online Open-Circuit Fault Diagnosis for ANPC Inverters Using Edge-Based Lightweight Two-Dimensional CNN

    by Chunxing Yao, Shuai Xu, Guanzhou Ren, Sijia Wu, Guohua Li, Zhenyao Sun, Guangtong Ma

    Conventional neural network (CNN) has been extensively applied in the field of fault diagnosis for multilevel inverter. However, most CNN based diagnostic strategies are typically implemented offline. To accomplish precise and online diagnosis for the open-circuit (OC) fault of three-level active neutral-point-clamped (3L-ANPC) inverter, the trained CNN is deployed into an edge computation board. Furthermore, this letter utilizes TensorRT to facilitate the lightweight design of the trained CNN, thereby accelerating the diagnosis speed. In order to simplify the offline training, a specific optimization framework is employed to achieve the automatic adjustment of hyperparameters. Comparative evaluations are performed to highlight the training performance and the generalization ability of the proposed CNN. Finally, the proposed online diagnosis is experimentally validated through a 3L-ANPC inverter fed permanent magnet synchronous motor (PMSM) drives.