TLTeeranan Laohawiriyakamol

Teeranan Laohawiriyakamol

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Teeranan Laohawiriyakamol has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Population-specific CT-derived sarcopenia cutoff values and inter-vertebral level correlations in healthy Thai adults using automated muscle segmentation

    by Wisitsak Pakdee, Sorawat Sangkaew, Pattira Boonsri, Teeranan Laohawiriyakamol, Panjai Choochuen, Supparerk Laohawiriyakamol, Natee Ina, Pramot Tanutit

    Objectives: Establishing optimal sarcopenia cutoffs is essential, as L3 is not always included in CT imaging, and reference levels vary across populations. The absence of Southeast Asia-specific thresholds may lead to misclassification, highlighting the need for regionally appropriate diagnostic criteria. This study establishes population-specific sarcopenia cutoffs (T10-S1) in the Thai population and defines BMI-adjusted thresholds. It also assesses skeletal muscle index (SMI) correlations across vertebral levels to refine L3-based sarcopenia evaluation. Methods: This retrospective study analyzed 475 healthy Thai adults (aged 18-40 years) who underwent emergency department CT between January 2010 and June 2023. Skeletal muscle parameters were measured from T10 to S1 using custom software. Measurements included skeletal muscle area (SMA), skeletal muscle radiation attenuation (SMRA), SMI, and height-adjusted SMI (SMIH1). Sex-stratified analyses and correlations between vertebral levels were performed. Results: At L3, sarcopenia cutoffs using SMI and SMIH1 were 23.3 cm2/m2 and 37.1 cm2/m for females, and 31.3 cm2/m2 and 53.9 cm2/m for males, respectively. Strong correlations were observed between L3 and adjacent vertebral levels (r > 0.8), with correlation strength decreasing with anatomical distance. Application of international cutoffs to the Thai population resulted in overestimation of sarcopenia cases. BMI-adjusted variable thresholds demonstrated superior diagnostic accuracy compared to fixed cutoffs. Conclusions: This study establishes the first population-specific sarcopenia reference values for Thai adults and validates the use of alternative vertebral levels when L3 imaging is unavailable. Our findings emphasize the importance of population-specific and BMI-adjusted cutoff values for accurate sarcopenia diagnosis in Thai adults. Advances in knowledge: This study establishes the first population-specific sarcopenia cutoff values for healthy Thai adults, providing the first evidence-based reference standards for the Thai populations. At L3, the recommended cutoffs are SMI 23.3 cm2/m2 and SMIH1 37.1 cm2/m for females, and SMI 31.3 cm2/m2 and SMIH1 53.9 cm2/m for males. Strong correlations (r > 0.8) between L3 and adjacent vertebral levels validate the use of alternative assessment sites when L3 imaging is unavailable: T12-L1 for chest CT protocols, L3 for abdominal CT protocols, and L4-L5 for pelvic CT protocols. Application of Western cutoffs to the Thai populations results in significant overestimation of sarcopenia prevalence, emphasizing the critical importance of population-specific diagnostic criteria.

  • Open Access

    Magnetic Resonance Imaging in Evaluation of Bone Tumor Matrix: Diagnostic Value and Matrix Characteristics

    by Wisitsak Pakdee, Warunee Kaewpiboon, Teeranan Laohawiriyakamol, Pattira Boonsri, Khanin Iamthanaporn, Pramot Tanutit

    Objective: Plain radiographs are vital for initial evaluations of bone tumors. However, multiplanar imaging; like magnetic resonance imaging (MRI), is often necessary for inconclusive cases. Hence, we aimed to determine the diagnostic value of MRI in evaluating bone tumor matrix and analyzing MRI characteristics of the matrix.Material and Methods: This study reviewed 245 MRI and plain radiographs of pathologically confirmed bone tumors; including 123 mineralized and 122 non-mineralized bone tumors. A radiologist having 16 years of experience assessed tumor matrix characteristics, including border, signal intensity on T1-weighted (T1W), T2-weighted (T2W), and gradient-echo images, along with enhancement patterns. Sensitivity, specificity, and a 95% confidence interval were used to present diagnostic values.Results: MRI demonstrated a sensitivity and specificity of 78.1% and 87.7% in differentiating mineralized from non-mineralized matrices, compared to 75.6% and 92.6% for plain radiographs. Both modalities showed high sensitivity and specificity in evaluating osteoid and chondroid matrices (MRI: 80.3%/84.0%, 94.5%/96.8%; radiographs: 80.3%/72.0%, 95.1%/96.4% specificity). High specificity was noted in evaluating fibrous matrices (97.4%/99.6%) but with low sensitivity (23.5%/11.8%). MRI outperformed radiographs in subcategorizing fat, soft tissue, and cystic tumors. The chondroid matrix exhibited distinct characteristics on MRI (well-defined lobulated border with high/intermediate T2W and lobulated/peripheral enhancement), while osteoid and fibrous matrices showed similar features, except in T1W signal intensity. Non-mineralized tumors displayed varied characteristics.Conclusion: While plain radiographs are essential for initial bone tumor assessment, especially for mineralization, MRI is superior in evaluating tumor matrices and non-mineralized tissues in providing detailed characterization for staging and treatment planning.


  • Assessing Risk of Iatrogenic Peroneal Nerve Injury in All-Inside Lateral Meniscal Repair Between Standard Vs. Arthroscopic MRI

    by Pramot Tanutit, Pattira Boonsri, Teeranan Laohawiriyakamol, Tanarat Boonriong, Wachiraphan Parinyakhup, Boonsin Tangtrakulwanich, Chaiwat Chuaychoosakoon

    Background: Various studies have examined the risk of peroneal nerve injury with use of standard magnetic resonance imaging (MRI) of the knee. However, the position of the knee during standard MRI is different from that during an actual arthroscopic lateral meniscal repair. The purpose of the present study was to evaluate and compare the risk of peroneal nerve injury during simulated all-inside lateral meniscal repairs on the basis of MRI scans made with the knee in both positions. Methods: With use of axial MRI scans made with the knee in the standard position (i.e., in 30° of flexion) and in the actual position used during arthroscopic lateral meniscal repair (i.e., in a figure-of-4 position), direct lines were drawn to simulate the passage of a straight all-inside meniscal repair device from the anteromedial and anterolateral portals to the medial and lateral borders of the popliteus tendon. The distance from the closest passage of each line to the peroneal nerve was measured. If a line touched or passed through the peroneal nerve, a risk of iatrogenic injury was noted and a new line was drawn from the same portal to the outer border of the peroneal nerve. The danger area was measured from the first line to the new line along the joint capsule. Results: In 28 Thai patients, the shortest distances from each line to the peroneal nerve were significantly shorter on the MRI scans made with the knee in the standard position than on those made with the knee in the arthroscopic position (p < 0.05 for all). All danger areas on the MRI scans that were made with the knee in the arthroscopic position were included within the danger areas on the scans that were made with the knee in the standard position. Conclusions: Standard MRI scans of the knee can be used to determine the risk of peroneal nerve injury at the time of arthroscopic lateral meniscal repair, although the risks are slightly overestimated. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  • Open Access

    Accuracy of medial-side cutting guide compared to anterior cutting guide in distal femoral osteotomy of total knee arthroplasty

    by Khanin Iamthanaporn, Varah Yuenyongviwat, Teeranan Laohawiriyakamol, Pramot Tanutit