Yong-Wook Baek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yong-Wook Baek has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Kyu Hyuck Chung
College of Pharmacy, Kyungsung University, Busan, Republic of Korea
3 shared publications - Young-Hee Kim
National Institute of Environmental Research, Incheon, Korea
3 shared publications - Hae-Kwan Cheong
Department of Social and Preventive Medicine, Sungkyunkwan University School of Medicine, Suwon, Korea
2 shared publications - Jong-Hyeon Lee
Research Institute of Environmental Health and Safety, EH R&C Co., Incheon, Republic of Korea
2 shared publications Jungyun Lim
Humidifier Disinfectant Health Center, Environmental Health Research, National Institute of Environmental Research, Incheon 22689, South Korea
2 shared publications- Jungyun Lim
National Institute of Environmental Research, Incheon, Korea
2 shared publications
Latest Publications
- 25 October 2026
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- p. 1-10
Respiratory health risks associated with humidifier disinfectant exposure in South Korea: A systematic review and meta-analysis with exposure–response evaluation
Background Humidifier disinfectants (HDs) were used as household biocidal products to prevent microbial growth in humidifiers and were withdrawn from the South Korean market in 2011 following recognition of associated health risks. Although epidemiological studies have reported associations between HD exposure and various respiratory diseases, the overall strength of evidence and exposure–response relationships have not been comprehensively quantified. Objective This study aimed to systematically review and quantitatively synthesize observational studies to evaluate the association between HD exposure and respiratory diseases and to assess exposure–response relationships across multiple exposure metrics. Methods PubMed, Excerpta Medica Database, and the Cumulative Index to Nursing and Allied Health Literature were searched through September 19, 2025. The primary outcome was the pooled odds ratio (OR) for respiratory disease risk among exposed versus non-exposed individuals. Secondary outcomes assessed exposure–response relationships using categorical and continuous exposure metrics. Results Seventeen observational studies conducted in South Korea were included. HD exposure was associated with a markedly increased risk of respiratory diseases (pooled OR 7.02, 95% CI 1.97–24.98), with the strongest association observed for lung injury (pooled OR 94.53, 95% CI 61.31–145.73). Age-stratified subgroup analyses exhibited significantly elevated risks across adult, pediatric, and mixed-age populations. Exposure–response analyses demonstrated significant associations across multiple categorical exposure metrics, including usage duration, daily usage hours, cumulative use hours, airborne concentration, cumulative exposure level, longer use during sleep, and HD use during sleep. Continuous exposure analyses indicated that affected individuals had significantly longer cumulative use hours than unaffected individuals (pooled standardized mean difference 0.197, 95% CI 0.069–0.325). Significance This study provides quantitative evidence supporting strong associations between HD exposure and respiratory diseases and demonstrates consistent exposure–response relationships across multiple exposure metrics, supporting a causal relationship between inhalational exposure to HDs and adverse respiratory outcomes. Impact statement This study provides comprehensive quantitative evidence that humidifier disinfectant exposure is strongly associated with respiratory diseases and demonstrates consistent exposure–response relationships across multiple exposure metrics. These findings strengthen causal inference for inhalational toxicity of humidifier disinfectants and highlight the importance of exposure assessment in environmental health risk evaluation. The results provide important evidence for environmental health policy, risk assessment, and prevention strategies for inhalation exposure to household biocidal products.
- 25 October 2026
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- p. 1-10
Respiratory health risks associated with humidifier disinfectant exposure in South Korea: A systematic review and meta-analysis with exposure–response evaluation
Background Humidifier disinfectants (HDs) were used as household biocidal products to prevent microbial growth in humidifiers and were withdrawn from the South Korean market in 2011 following recognition of associated health risks. Although epidemiological studies have reported associations between HD exposure and various respiratory diseases, the overall strength of evidence and exposure–response relationships have not been comprehensively quantified. Objective This study aimed to systematically review and quantitatively synthesize observational studies to evaluate the association between HD exposure and respiratory diseases and to assess exposure–response relationships across multiple exposure metrics. Methods PubMed, Excerpta Medica Database, and the Cumulative Index to Nursing and Allied Health Literature were searched through September 19, 2025. The primary outcome was the pooled odds ratio (OR) for respiratory disease risk among exposed versus non-exposed individuals. Secondary outcomes assessed exposure–response relationships using categorical and continuous exposure metrics. Results Seventeen observational studies conducted in South Korea were included. HD exposure was associated with a markedly increased risk of respiratory diseases (pooled OR 7.02, 95% CI 1.97–24.98), with the strongest association observed for lung injury (pooled OR 94.53, 95% CI 61.31–145.73). Age-stratified subgroup analyses exhibited significantly elevated risks across adult, pediatric, and mixed-age populations. Exposure–response analyses demonstrated significant associations across multiple categorical exposure metrics, including usage duration, daily usage hours, cumulative use hours, airborne concentration, cumulative exposure level, longer use during sleep, and HD use during sleep. Continuous exposure analyses indicated that affected individuals had significantly longer cumulative use hours than unaffected individuals (pooled standardized mean difference 0.197, 95% CI 0.069–0.325). Significance This study provides quantitative evidence supporting strong associations between HD exposure and respiratory diseases and demonstrates consistent exposure–response relationships across multiple exposure metrics, supporting a causal relationship between inhalational exposure to HDs and adverse respiratory outcomes. Impact statement This study provides comprehensive quantitative evidence that humidifier disinfectant exposure is strongly associated with respiratory diseases and demonstrates consistent exposure–response relationships across multiple exposure metrics. These findings strengthen causal inference for inhalational toxicity of humidifier disinfectants and highlight the importance of exposure assessment in environmental health risk evaluation. The results provide important evidence for environmental health policy, risk assessment, and prevention strategies for inhalation exposure to household biocidal products.
- Open Access
- 15 May 2025
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 298, 118284
Strain and sex differences in chloromethylisothiazolinone and methylisothiazolinone-induced lung injury in mice
- 15 May 2025
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 298, 118284
Open AccessStrain and sex differences in chloromethylisothiazolinone and methylisothiazolinone-induced lung injury in mice
- Open Access
- 21 February 2025
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 292, 117930
Polyhexamethylene guanidine phosphate induces epithelial-to-mesenchymal transition and cancer stem cell-like properties via Wnt/β-catenin signaling in human bronchial epithelial cells
- 21 February 2025
- Published by Elsevier in Ecotoxicology and Environmental Safety
- Vol. 292, 117930
Open AccessPolyhexamethylene guanidine phosphate induces epithelial-to-mesenchymal transition and cancer stem cell-like properties via Wnt/β-catenin signaling in human bronchial epithelial cells
- Open Access
- 24 November 2024
- Published by Elsevier in Chemosphere
- Vol. 368, 143785
Deciphering the toxicity of polyhexamethylene guanidine phosphate in lung carcinogenesis: Mutational profiles and molecular mechanisms
- 24 November 2024
- Published by Elsevier in Chemosphere
- Vol. 368, 143785
Open AccessDeciphering the toxicity of polyhexamethylene guanidine phosphate in lung carcinogenesis: Mutational profiles and molecular mechanisms
- 3 August 2024
- Published by Elsevier in Chemosphere
- Vol. 364, 143010
A systematic review and BMD modeling approach to develop an AOP for humidifier disinfectant-induced pulmonary fibrosis and cell death
- 3 August 2024
- Published by Elsevier in Chemosphere
- Vol. 364, 143010
A systematic review and BMD modeling approach to develop an AOP for humidifier disinfectant-induced pulmonary fibrosis and cell death
- Open Access
- 7 July 2024
- Published by Korean Society of Epidemiology in Epidemiology and Health
- Vol. 46, e2024060
Toxicological evidence integration to confirm the biological plausibility of the association between humidifier disinfectant exposure and respiratory diseases using the AEP-AOP framework
OBJECTIVES: Exposure to humidifier disinfectants has been linked to respiratory diseases, including interstitial lung disease, asthma, and pneumonia. Consequently, numerous toxicological studies have explored respiratory damage as both a necessary and sufficient condition for these diseases. We systematically reviewed and integrated evidence from toxicological studies by applying the evidence integration method established in previous research to confirm the biological plausibility of the association between exposure and disease.METHODS: We conducted a literature search focusing on polyhexamethylene guanidine phosphate (PHMG) and chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT), the primary ingredients in humidifier disinfectants. We selected relevant studies based on their quality and the population, exposure, comparator, outcome (PECO) statements. These studies were categorized into three lines of evidence: hazard information, animal studies, and mechanistic studies. Based on a systematic review, we integrated the evidence to develop an aggregate exposure pathway–adverse outcome pathway (AEP-AOP) model for respiratory damage. The reliability and relevance of our findings were assessed by comparing them with the hypothesized pathogenic mechanisms of respiratory diseases.RESULTS: By integrating toxicological evidence for each component of the AEP-AOP framework for PHMG and CMIT/MIT, we developed an AEP-AOP model that elucidates how disinfectants released from humidifiers expose target sites, triggering molecular initiating events and key events that ultimately lead to respiratory damage. This model exhibits high reliability and relevance to the pathogenesis of respiratory diseases.CONCLUSIONS: The AEP-AOP model developed in this study provides strong evidence, based on evidence-based toxicology, that exposure to humidifier disinfectants causes respiratory diseases. This model demonstrates the pathways leading to respiratory damage, a hallmark of these conditions.
- 7 July 2024
- Published by Korean Society of Epidemiology in Epidemiology and Health
- Vol. 46, e2024060
Open AccessToxicological evidence integration to confirm the biological plausibility of the association between humidifier disinfectant exposure and respiratory diseases using the AEP-AOP framework
OBJECTIVES: Exposure to humidifier disinfectants has been linked to respiratory diseases, including interstitial lung disease, asthma, and pneumonia. Consequently, numerous toxicological studies have explored respiratory damage as both a necessary and sufficient condition for these diseases. We systematically reviewed and integrated evidence from toxicological studies by applying the evidence integration method established in previous research to confirm the biological plausibility of the association between exposure and disease.METHODS: We conducted a literature search focusing on polyhexamethylene guanidine phosphate (PHMG) and chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT), the primary ingredients in humidifier disinfectants. We selected relevant studies based on their quality and the population, exposure, comparator, outcome (PECO) statements. These studies were categorized into three lines of evidence: hazard information, animal studies, and mechanistic studies. Based on a systematic review, we integrated the evidence to develop an aggregate exposure pathway–adverse outcome pathway (AEP-AOP) model for respiratory damage. The reliability and relevance of our findings were assessed by comparing them with the hypothesized pathogenic mechanisms of respiratory diseases.RESULTS: By integrating toxicological evidence for each component of the AEP-AOP framework for PHMG and CMIT/MIT, we developed an AEP-AOP model that elucidates how disinfectants released from humidifiers expose target sites, triggering molecular initiating events and key events that ultimately lead to respiratory damage. This model exhibits high reliability and relevance to the pathogenesis of respiratory diseases.CONCLUSIONS: The AEP-AOP model developed in this study provides strong evidence, based on evidence-based toxicology, that exposure to humidifier disinfectants causes respiratory diseases. This model demonstrates the pathways leading to respiratory damage, a hallmark of these conditions.
- Open Access
- 24 October 2023
- Published by Korean Society of Epidemiology in Epidemiology and Health
- Vol. 45, e2023095
Evidence integration on health damage for humidifier disinfectant exposure and legal presumption of causation
OBJECTIVES: Inhalation exposure to humidifier disinfectants has resulted to various types of health damages in Korea. To determine the epidemiological correlation necessary for presuming the legal causation, we aimed to develop a method to synthesize the entire evidence.METHODS: Epidemiological and toxicological studies are systematically reviewed. Target health problems are selected by criteria such as frequent complaints of claimants. Relevant epidemiologic studies are reviewed and the risk of bias and confidence level of the total evidence are evaluated. Toxicological literature reviews are conducted on three lines of evidence including hazard information, animal studies, and mechanistic studies, considering the source-to-exposure-to-outcome continuum. The confidence level of the body of evidence is then translated into the toxicological evidence levels for the causality between humidifier disinfectant exposure and health effects. Finally, the levels of epidemiological and toxicological evidence are synthesized.RESULTS: Under the Special Act revised in 2020, if the history of exposure and the disease occurred/worsened after exposure were approved, and the epidemiological correlation between the exposure and disease was verified, the legal causation is presumed unless the company proves the evidence against it. The epidemiological correlation can be verified through epidemiological investigations, health monitoring, cohort investigations and/or toxicological studies. It is not simply as statistical association as understood in judicial precedents, but a general causation established by the evidence as a whole, i.e., through weight-of-the-evidence approach.CONCLUSIONS: The weight-of-the-evidence approach differs from the conclusive single study approach and this systematic evidence integration can be used in presumption of causation.
- 24 October 2023
- Published by Korean Society of Epidemiology in Epidemiology and Health
- Vol. 45, e2023095
Open AccessEvidence integration on health damage for humidifier disinfectant exposure and legal presumption of causation
OBJECTIVES: Inhalation exposure to humidifier disinfectants has resulted to various types of health damages in Korea. To determine the epidemiological correlation necessary for presuming the legal causation, we aimed to develop a method to synthesize the entire evidence.METHODS: Epidemiological and toxicological studies are systematically reviewed. Target health problems are selected by criteria such as frequent complaints of claimants. Relevant epidemiologic studies are reviewed and the risk of bias and confidence level of the total evidence are evaluated. Toxicological literature reviews are conducted on three lines of evidence including hazard information, animal studies, and mechanistic studies, considering the source-to-exposure-to-outcome continuum. The confidence level of the body of evidence is then translated into the toxicological evidence levels for the causality between humidifier disinfectant exposure and health effects. Finally, the levels of epidemiological and toxicological evidence are synthesized.RESULTS: Under the Special Act revised in 2020, if the history of exposure and the disease occurred/worsened after exposure were approved, and the epidemiological correlation between the exposure and disease was verified, the legal causation is presumed unless the company proves the evidence against it. The epidemiological correlation can be verified through epidemiological investigations, health monitoring, cohort investigations and/or toxicological studies. It is not simply as statistical association as understood in judicial precedents, but a general causation established by the evidence as a whole, i.e., through weight-of-the-evidence approach.CONCLUSIONS: The weight-of-the-evidence approach differs from the conclusive single study approach and this systematic evidence integration can be used in presumption of causation.