Albert Ngu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Albert Ngu has a total of 227 co-authors. Here are the top co-authors by number of shared publications:
- Azeem Thahir
Clinical Fellow, Department of Trauma & Orthopaedics, Cambridge University Hospitals NHS Trust, Cambridge, UK
3 shared publications - Andreas Rehm
Department of Paediatric Orthopaedics, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
2 shared publications Aaron Rooney
1 shared publication- Abdus Samee Wasim1 shared publication
- Abhinav Singh
Oxford University
1 shared publication - Adam Smith1 shared publication
Latest Publications
- 1 October 2022
- Published by Elsevier in The Surgeon
- Vol. 20 (5) , 291-296
Access and feasibility of orthopaedic training in the independent sector – A Deanery's experience
- 1 October 2022
- Published by Elsevier in The Surgeon
- Vol. 20 (5) , 291-296
Access and feasibility of orthopaedic training in the independent sector – A Deanery's experience
- Open Access
- 7 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-3
Efficacy of ultra-early rehabilitation on elbow function after Slongo’s external fixation for supracondylar humeral fractures in older children and adolescents
- 7 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-3
Open AccessEfficacy of ultra-early rehabilitation on elbow function after Slongo’s external fixation for supracondylar humeral fractures in older children and adolescents
- 1 December 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (6) , e331-e337
Collaborative Overview of coronaVIrus impact on ORTHopaedic training in the UK (COVI - ORTH UK)
- 1 December 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (6) , e331-e337
Collaborative Overview of coronaVIrus impact on ORTHopaedic training in the UK (COVI - ORTH UK)
- Open Access
- 3 November 2021
- Vol. 92 (5) , e2021359
Comment on "Medial epicondyle avulsion after elbow dislocation in an adolescent non-professional soccer player treated with a cannulated screw: a case report.".
- 3 November 2021
- Vol. 92 (5) , e2021359
Open AccessComment on "Medial epicondyle avulsion after elbow dislocation in an adolescent non-professional soccer player treated with a cannulated screw: a case report.".
- 14 September 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (3) , 517-518
Pediatric Femoral Shaft Fracture: An Age-Based Treatment Algorithm. Liau GZQ, Lin HY, Wang Y, Nistala KRY, Cheong CK, Hui JHP. Indian J Orthop. 2020 Oct 10;55(1):55–67. doi:10.1007/s43465-020-00281-6. eCollection 2021 Feb
- 14 September 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 56 (3) , 517-518
Pediatric Femoral Shaft Fracture: An Age-Based Treatment Algorithm. Liau GZQ, Lin HY, Wang Y, Nistala KRY, Cheong CK, Hui JHP. Indian J Orthop. 2020 Oct 10;55(1):55–67. doi:10.1007/s43465-020-00281-6. eCollection 2021 Feb
- Open Access
- 1 December 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (23) , 725
Single 3° tapered fluted femoral stems demonstrate low subsidence at mid-term follow-up in severe bony deficiency
Background: Tapered femoral stems have become popular in revision total hip arthroplasty (rTHA). Increasing the distal taper angle may mitigate subsidence. This study reports osseointegration of a new 3 degree distal taper revision stem at minimum 4 years post-operatively. Methods: Indication for surgery, pre-operative bony deficiency and latest clinical, tribological and radiological follow-up were analysed. Radiographs were assessed by two blinded observers for preoperative femoral bone stock according to Paprosky, postoperative subsidence according to Callaghan and restoration of femoral bone stock over time according to Kolstad. Stem integration was determined using the Rodriguez classification. Results: Twenty-three cases were analyzed at 5.9±1.0 years. All patients presented with Paprosky III defects. All stems met the criteria for osseointegration. Spot welds occurred distal to the proximal modular junction and at the tip. Two femora with severe proximal femoral bone loss recovered bone stock by final follow-up but two demonstrated stress shielding. No intraoperative fractures occurred. One stem subsided early but remained stable and osseointegrated at final follow up. There were no stem failures due to taper corrosion or modular junctional failure. Conclusions: This study reports good osseointegration and low subsidence with a novel fluted, 3-degree tapered femoral stem demonstrates at medium-term follow-up in cases with severe femoral bone deficiency.
- 1 December 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (23) , 725
Open AccessSingle 3° tapered fluted femoral stems demonstrate low subsidence at mid-term follow-up in severe bony deficiency
Background: Tapered femoral stems have become popular in revision total hip arthroplasty (rTHA). Increasing the distal taper angle may mitigate subsidence. This study reports osseointegration of a new 3 degree distal taper revision stem at minimum 4 years post-operatively. Methods: Indication for surgery, pre-operative bony deficiency and latest clinical, tribological and radiological follow-up were analysed. Radiographs were assessed by two blinded observers for preoperative femoral bone stock according to Paprosky, postoperative subsidence according to Callaghan and restoration of femoral bone stock over time according to Kolstad. Stem integration was determined using the Rodriguez classification. Results: Twenty-three cases were analyzed at 5.9±1.0 years. All patients presented with Paprosky III defects. All stems met the criteria for osseointegration. Spot welds occurred distal to the proximal modular junction and at the tip. Two femora with severe proximal femoral bone loss recovered bone stock by final follow-up but two demonstrated stress shielding. No intraoperative fractures occurred. One stem subsided early but remained stable and osseointegrated at final follow up. There were no stem failures due to taper corrosion or modular junctional failure. Conclusions: This study reports good osseointegration and low subsidence with a novel fluted, 3-degree tapered femoral stem demonstrates at medium-term follow-up in cases with severe femoral bone deficiency.