Gihoon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gihoon Kim has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Minki Sung
Sejong University
9 shared publications - Seongmin Jo
Korea Institute of Civil Engineering and Building Technology
6 shared publications - Jehyun Kim
Department of Physics and Astronomy, Seoul National University, Seoul 08826, Korea
2 shared publications - Jong-Il Bang
Sejong University, Department of Architectural Engineering, Seoul, Korea
2 shared publications - An-Seop Choi
Department of Architectural Engineering, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul 05006, Korea
1 shared publication Anseop Choi
Sejong University
1 shared publication
Latest Publications
- 23 September 2026
- Published by SAGE Publications in Indoor and Built Environment
Particle inflow characteristics in airborne infection isolation rooms: Effects of airflow rate difference induced by pressure difference and door leakage area
Airborne infection isolation (AII) rooms are designed to maintain negative pressure relative to adjacent spaces to prevent the spread of emerging infectious diseases. However, contaminant inflow through door leakage can deteriorate indoor air quality and increase secondary infection risks for patients. Current guidelines emphasize maintaining pressure differences but do not address airflow rate differences, which directly influence contaminant inflow. This study evaluated the impact of airflow rate differences on particle inflow through full-scale chamber experiments. Experimental conditions were established by varying door undercut heights and pressure differences. Particle concentrations were monitored at the exhaust diffusers of the AII room and anteroom. The results showed that as the airflow rate difference increased from 117 to 500 m 3 /h, the particle inflow rate increased from 257 × 10 6 to 1327 × 10 6 counts/s (linear correlation, R 2 = 0.999), and the particle inflow ratio increased from 71.0% to 86.5% (logarithmic correlation, R 2 = 0.994). Furthermore, cases with identical airflow rate differences showed similar particle inflow ratios regardless of pressure differences or door leakage areas, confirming airflow rate difference as the key factor. These findings underscore the limitations of pressure-focused guidelines and suggest that airflow rate differences should be incorporated into AII room design and operational guidelines.
- 23 September 2026
- Published by SAGE Publications in Indoor and Built Environment
Particle inflow characteristics in airborne infection isolation rooms: Effects of airflow rate difference induced by pressure difference and door leakage area
Airborne infection isolation (AII) rooms are designed to maintain negative pressure relative to adjacent spaces to prevent the spread of emerging infectious diseases. However, contaminant inflow through door leakage can deteriorate indoor air quality and increase secondary infection risks for patients. Current guidelines emphasize maintaining pressure differences but do not address airflow rate differences, which directly influence contaminant inflow. This study evaluated the impact of airflow rate differences on particle inflow through full-scale chamber experiments. Experimental conditions were established by varying door undercut heights and pressure differences. Particle concentrations were monitored at the exhaust diffusers of the AII room and anteroom. The results showed that as the airflow rate difference increased from 117 to 500 m 3 /h, the particle inflow rate increased from 257 × 10 6 to 1327 × 10 6 counts/s (linear correlation, R 2 = 0.999), and the particle inflow ratio increased from 71.0% to 86.5% (logarithmic correlation, R 2 = 0.994). Furthermore, cases with identical airflow rate differences showed similar particle inflow ratios regardless of pressure differences or door leakage areas, confirming airflow rate difference as the key factor. These findings underscore the limitations of pressure-focused guidelines and suggest that airflow rate differences should be incorporated into AII room design and operational guidelines.
- 20 November 2025
- Published by Elsevier in Building and Environment
- Vol. 288
CO2 concentration prediction in office spaces using physics-informed neural network based on number of occupants and IoT sensor data
- 20 November 2025
- Published by Elsevier in Building and Environment
- Vol. 288
CO2 concentration prediction in office spaces using physics-informed neural network based on number of occupants and IoT sensor data
- 20 March 2025
- Published by Elsevier in Building and Environment
- Vol. 276
Performance evaluation of the individual room control-negative pressure ventilation system in apartment
- 20 March 2025
- Published by Elsevier in Building and Environment
- Vol. 276
Performance evaluation of the individual room control-negative pressure ventilation system in apartment
- Open Access
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Predicting and Analyzing Indoor Air Quality in Inpatient Wards Using IoT‐Based Long‐Term Data and Machine Learning
Indoor air quality (IAQ) plays a crucial role in safeguarding the health of both patients and healthcare workers in hospital environments. Accurate IAQ analysis and prediction are vital for optimizing ventilation, filtration, and other control measures to maintain a safe indoor atmosphere. This study investigates IAQ in hospital spaces by utilizing long‐term data from internet of things (IoT) sensors installed in general wards and negative pressure isolation wards. Given the significant influence of outdoor air, IAQ requires continuous monitoring across different seasons and extended periods. In this study, IAQ was measured over nearly a year, capturing seasonal variations and long‐term trends. Clustering algorithms were applied to identify complex patterns and detect anomalies in key IAQ parameters, including temperature, CO 2 concentration, and particulate matter 2.5 μ m (PM 2.5 ). These clustering results were then integrated into a long short‐term memory (LSTM) model to enhance IAQ prediction for subsequent time steps. The findings indicate that incorporating clustering results as input variables substantially improves IAQ prediction accuracy. Notably, the root mean squared error for PM 2.5 prediction decreased from 8.51 to 3.99 when clustering results were included. This study underscores the potential of leveraging IoT sensors and machine learning techniques for real‐time IAQ monitoring and forecasting in hospital settings. These insights can support the development of effective control strategies to maintain a healthy and comfortable indoor environment for both patients and healthcare workers.
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Open AccessPredicting and Analyzing Indoor Air Quality in Inpatient Wards Using IoT‐Based Long‐Term Data and Machine Learning
Indoor air quality (IAQ) plays a crucial role in safeguarding the health of both patients and healthcare workers in hospital environments. Accurate IAQ analysis and prediction are vital for optimizing ventilation, filtration, and other control measures to maintain a safe indoor atmosphere. This study investigates IAQ in hospital spaces by utilizing long‐term data from internet of things (IoT) sensors installed in general wards and negative pressure isolation wards. Given the significant influence of outdoor air, IAQ requires continuous monitoring across different seasons and extended periods. In this study, IAQ was measured over nearly a year, capturing seasonal variations and long‐term trends. Clustering algorithms were applied to identify complex patterns and detect anomalies in key IAQ parameters, including temperature, CO 2 concentration, and particulate matter 2.5 μ m (PM 2.5 ). These clustering results were then integrated into a long short‐term memory (LSTM) model to enhance IAQ prediction for subsequent time steps. The findings indicate that incorporating clustering results as input variables substantially improves IAQ prediction accuracy. Notably, the root mean squared error for PM 2.5 prediction decreased from 8.51 to 3.99 when clustering results were included. This study underscores the potential of leveraging IoT sensors and machine learning techniques for real‐time IAQ monitoring and forecasting in hospital settings. These insights can support the development of effective control strategies to maintain a healthy and comfortable indoor environment for both patients and healthcare workers.
- 6 December 2024
- Published by Springer Nature
- p. 84-90
Assessment of Negative Pressure Environment Using Convertible Air Handling Unit in Full-Scale Chamber
- 6 December 2024
- Published by Springer Nature
- p. 84-90
Assessment of Negative Pressure Environment Using Convertible Air Handling Unit in Full-Scale Chamber
- Open Access
- 27 July 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Impact of medical staff movement, airflow rate difference, and door leakage area on particle outflow in an airborne infection isolation room
- 27 July 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Open AccessImpact of medical staff movement, airflow rate difference, and door leakage area on particle outflow in an airborne infection isolation room
- Open Access
- 21 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 86
A study on contaminant leakage from Airborne Infection Isolation room during medical staff entry; Implementation of walking motion on hypothetical human model in CFD simulation
- 21 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 86
Open AccessA study on contaminant leakage from Airborne Infection Isolation room during medical staff entry; Implementation of walking motion on hypothetical human model in CFD simulation
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01025
Contaminant removal effectiveness evaluation of ventilation, UR-UVGI, and air cleaner using CFD in negative pressure isolation ward
A negative pressure isolation ward (NPIW) is designed to create negative pressure to prevent the spread of airborne viruses. Therefore, it is necessary to increase the contaminant removal effect in the NPIW. To reduce indoor air contaminants, upper room-ultraviolet germicidal irradiation (UR-UVGI) and air cleaner are being used. Unlike the UR-UVGI, the air cleaner generates airflow. Therefore, the contaminant removal effect may differ according to the ventilation methods. This study is to compare ventilation, UR-UVGI, and air cleaner contaminant removal effects using CFD and Contaminant Removal Effectiveness (CRE) in the NPIW. As a result, the CRE of the ceiling and wall exhaust methods were different, and the CRE of the URUVGI and air cleaner cases were also different according to the two ventilation methods. Therefore, when applying UR-UVGI and air cleaner, it is necessary to consider the ventilation method.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01025
Open AccessContaminant removal effectiveness evaluation of ventilation, UR-UVGI, and air cleaner using CFD in negative pressure isolation ward
A negative pressure isolation ward (NPIW) is designed to create negative pressure to prevent the spread of airborne viruses. Therefore, it is necessary to increase the contaminant removal effect in the NPIW. To reduce indoor air contaminants, upper room-ultraviolet germicidal irradiation (UR-UVGI) and air cleaner are being used. Unlike the UR-UVGI, the air cleaner generates airflow. Therefore, the contaminant removal effect may differ according to the ventilation methods. This study is to compare ventilation, UR-UVGI, and air cleaner contaminant removal effects using CFD and Contaminant Removal Effectiveness (CRE) in the NPIW. As a result, the CRE of the ceiling and wall exhaust methods were different, and the CRE of the URUVGI and air cleaner cases were also different according to the two ventilation methods. Therefore, when applying UR-UVGI and air cleaner, it is necessary to consider the ventilation method.