Samik Roy Moulik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samik Roy Moulik has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Aida Amini
Institut National de la Recherche Scientifique (INRS), Center of Energy, Materials, and Telecommunications , Varennes, Quebec J3X 1P7
1 shared publication - Amanda Persdotter
Department of Mechanical Engineering Chalmers University of Technology Göteborg Sweden
1 shared publication - Jinyang Liang
Institut National de la Recherche Scientifique
1 shared publication - Kenneth R. Beyerlein
Centre Énergie Matériaux Télécommunications, Institut National de la Recherche Scientifique (INRS) , Varennes, QC , Canada
1 shared publication - Kuray Dericiler
Department of Physics and Astronomy Chalmers University of Technology Göteborg Sweden
1 shared publication - Lorenzo Stievano
ICGM, Univ. Montpellier, CNRS, ENSCM
1 shared publication
Latest Publications
- Open Access
- 5 November 2026
- Published by Wiley in Batteries & Supercaps
- Vol. 9 (11)
(De)Sodiation Mechanisms and Cycling Stability of Entropy‐Engineered Sodium‐Ion Battery Alloy Anodes by Operando X‐ray Diffraction
Alloy anodes represent a high‐capacity alternative to the prevalent hard carbon‐based anodes for sodium ion‐batteries. The major challenge is their large volumetric changes during (de)sodiation, consuming electrolyte and ultimately leading to pulverization of the anode and hence limited cycle life of the battery. To overcome this fundamental challenge, a proof‐of‐concept solution is introduced in SnSbBiSe 1.5 Te 1.5 , a high‐entropy alloy, as shown by comparing its cycling performance with those of its low‐entropy (Sb 2 Te 3 ) and medium‐entropy (SbBiSe 1.5 Te 1.5 ) analogs. Using operando synchrotron X‐ray diffraction, major differences are revealed during the (de)sodiation as function of configurational entropy, and by cross‐sectional SEM further insight is gained on the roles of particle size and distribution, both initially and after cycling. Overall, this study highlights the importance of entropy‐engineered and controlled particle size alloy anodes to limit volumetric changes and render stable cycling.
- 5 November 2026
- Published by Wiley in Batteries & Supercaps
- Vol. 9 (11)
Open Access(De)Sodiation Mechanisms and Cycling Stability of Entropy‐Engineered Sodium‐Ion Battery Alloy Anodes by Operando X‐ray Diffraction
Alloy anodes represent a high‐capacity alternative to the prevalent hard carbon‐based anodes for sodium ion‐batteries. The major challenge is their large volumetric changes during (de)sodiation, consuming electrolyte and ultimately leading to pulverization of the anode and hence limited cycle life of the battery. To overcome this fundamental challenge, a proof‐of‐concept solution is introduced in SnSbBiSe 1.5 Te 1.5 , a high‐entropy alloy, as shown by comparing its cycling performance with those of its low‐entropy (Sb 2 Te 3 ) and medium‐entropy (SbBiSe 1.5 Te 1.5 ) analogs. Using operando synchrotron X‐ray diffraction, major differences are revealed during the (de)sodiation as function of configurational entropy, and by cross‐sectional SEM further insight is gained on the roles of particle size and distribution, both initially and after cycling. Overall, this study highlights the importance of entropy‐engineered and controlled particle size alloy anodes to limit volumetric changes and render stable cycling.
- Open Access
- 1 January 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (1) , 014303
Spatial–temporal characterization of photoemission in a streak-mode dynamic transmission electron microscope
A long-standing motivation driving high-speed electron microscopy development is to capture phase transformations and material dynamics in real time with high spatial and temporal resolution. Current dynamic transmission electron microscopes (DTEMs) are limited to nanosecond temporal resolution and the ability to capture only a few frames of a transient event. With the motivation to overcome these limitations, we present our progress in developing a streak-mode DTEM (SM-DTEM) and demonstrate the recovery of picosecond images with high frame sequence depth. We first demonstrate that a zero-dimensional (0D) SM-DTEM can provide temporal information on any local region of interest with a 0.37 μm diameter, a 20-GHz sampling rate, and 1200 data points in the recorded trace. We use this method to characterize the temporal profile of the photoemitted electron pulse, finding that it deviates from the incident ultraviolet laser pulse and contains an unexpected peak near its onset. Then, we demonstrate a two-dimensional (2D) SM-DTEM, which uses compressed-sensing-based tomographic imaging to recover a full spatiotemporal photoemission profile over a 1.85-μm-diameter field of view with nanoscale spatial resolution, 370-ps inter-frame interval, and 140-frame sequence depth in a 50-ns time window. Finally, a perspective is given on the instrumental modifications necessary to further develop this promising technique with the goal of decreasing the time to capture a 2D SM-DTEM dataset.
- 1 January 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (1) , 014303
Open AccessSpatial–temporal characterization of photoemission in a streak-mode dynamic transmission electron microscope
A long-standing motivation driving high-speed electron microscopy development is to capture phase transformations and material dynamics in real time with high spatial and temporal resolution. Current dynamic transmission electron microscopes (DTEMs) are limited to nanosecond temporal resolution and the ability to capture only a few frames of a transient event. With the motivation to overcome these limitations, we present our progress in developing a streak-mode DTEM (SM-DTEM) and demonstrate the recovery of picosecond images with high frame sequence depth. We first demonstrate that a zero-dimensional (0D) SM-DTEM can provide temporal information on any local region of interest with a 0.37 μm diameter, a 20-GHz sampling rate, and 1200 data points in the recorded trace. We use this method to characterize the temporal profile of the photoemitted electron pulse, finding that it deviates from the incident ultraviolet laser pulse and contains an unexpected peak near its onset. Then, we demonstrate a two-dimensional (2D) SM-DTEM, which uses compressed-sensing-based tomographic imaging to recover a full spatiotemporal photoemission profile over a 1.85-μm-diameter field of view with nanoscale spatial resolution, 370-ps inter-frame interval, and 140-frame sequence depth in a 50-ns time window. Finally, a perspective is given on the instrumental modifications necessary to further develop this promising technique with the goal of decreasing the time to capture a 2D SM-DTEM dataset.