Avni Mody
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Avni Mody has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Alex B. Haynes
Univ Texas Austin, Austin, TX 78712 USA
1 shared publication - Claudia V. Emery
Texas Children's Hospital, Department of Audiology, 6621 Fannin Street 5th Floor, Houston, TX 77030, USA
1 shared publication - Jeffrey T. Vrabec
Houston Methodist ENT Specialists, Houston, TX, USA
1 shared publication - Jerry Lin
Department of Viticulture and Enology, University of California Davis , Davis, CA 95616
1 shared publication Jody Haymond
Bobby R. Alford Department of Otolaryngology–Head and Neck Surgery, Baylor College of Medicine and the Hearing Center at Texas Children's Hospital, Houston, Texas, U.S.A.
1 shared publication- John S. Oghalai
Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, California, USA
1 shared publication
Latest Publications
- Open Access
- 8 January 2024
- Published by The Endocrine Society in JCEM Case Reports
- Vol. 2 (2) , luae017
Doege-Potter Syndrome: A Solitary Fibrous Tumor Causing Non-Islet Cell Tumor Hypoglycemia
Doege-Potter syndrome occurs when incompletely processed insulin-like growth factor 2 (IGF-2), also known as big IGF-2, is produced by a solitary fibrous tumor (SFT) and results in non-islet cell tumor hypoglycemia (NICTH). We discuss here the case of a 66-year-old male who presented with a 2-week history of increasing confusion and a serum glucose of 34 mg/dL. The patient's symptoms immediately improved with dextrose. The patient did not use insulin, serum sulfonylurea screen was negative, and testing for adrenal insufficiency was unremarkable. Outpatient laboratory evaluation revealed a serum glucose of 48 mg/dL along with low insulin, C-peptide, and proinsulin levels. Further work-up showed an IGF-2 to IGF-1 ratio of 38:1. A ratio greater than 10:1 is diagnostic of NICTH. Imaging demonstrated a 21-cm mass in the lower abdomen and pelvis. The patient underwent surgical resection. The hypoglycemia resolved immediately postoperatively. Surgical pathology revealed a malignant SFT. In NICTH, big IGF-2 forms a complex that is biologically active and saturates the insulin and IGF receptors, resulting in refractory hypoglycemia. Although glucocorticoids can mitigate hypoglycemia, complete surgical resection is the only definitive treatment of NICTH. This case highlights the importance of maintaining a broad differential for seemingly simple hypoglycemia.
- 8 January 2024
- Published by The Endocrine Society in JCEM Case Reports
- Vol. 2 (2) , luae017
Open AccessDoege-Potter Syndrome: A Solitary Fibrous Tumor Causing Non-Islet Cell Tumor Hypoglycemia
Doege-Potter syndrome occurs when incompletely processed insulin-like growth factor 2 (IGF-2), also known as big IGF-2, is produced by a solitary fibrous tumor (SFT) and results in non-islet cell tumor hypoglycemia (NICTH). We discuss here the case of a 66-year-old male who presented with a 2-week history of increasing confusion and a serum glucose of 34 mg/dL. The patient's symptoms immediately improved with dextrose. The patient did not use insulin, serum sulfonylurea screen was negative, and testing for adrenal insufficiency was unremarkable. Outpatient laboratory evaluation revealed a serum glucose of 48 mg/dL along with low insulin, C-peptide, and proinsulin levels. Further work-up showed an IGF-2 to IGF-1 ratio of 38:1. A ratio greater than 10:1 is diagnostic of NICTH. Imaging demonstrated a 21-cm mass in the lower abdomen and pelvis. The patient underwent surgical resection. The hypoglycemia resolved immediately postoperatively. Surgical pathology revealed a malignant SFT. In NICTH, big IGF-2 forms a complex that is biologically active and saturates the insulin and IGF receptors, resulting in refractory hypoglycemia. Although glucocorticoids can mitigate hypoglycemia, complete surgical resection is the only definitive treatment of NICTH. This case highlights the importance of maintaining a broad differential for seemingly simple hypoglycemia.
- Open Access
- 30 November 2009
- Published by Wiley in The Laryngoscope
- Vol. 120 (2) , 399-404
Characteristics of malfunctioning channels in pediatric cochlear implants
Objectives/Hypothesis: To examine the characteristics of pediatric cochlear implant channel malfunction preceding device failure.Study Design: Retrospective review.Methods: All pediatric patients who underwent cochlear implantation at a tertiary academic medical center were reviewed regarding device type, reason for replacement, time to replacement, and timing and pattern of channel faults in failed versus nonfailed devices.Results: Between 1993 and 2008, 264 pediatric cochlear implantations were performed. With an average 894‐day follow‐up, the replacement rate was 9.5% (25/264). Reasons for replacement were device failure (6.4%), medical/surgical failure (2.3%), and obsolescence (0.8%). Replacement rates were comparable among Advanced Bionics (13.3%), Cochlear Corporation (6.3%), and MED‐EL (10.3%) devices. Fifty‐two cochlear implants developed at least one channel fault, and 13 eventually progressed to failure requiring replacement. MED‐EL devices comprised 12 of these 13 failures. At the 12‐month follow‐up interval, one, three, and five channel faults predicted 40%, 75%, and 100% probabilities of eventual electrode failure, respectively. Channels destined to fail demonstrated small, yet statistically significant, impedance elevations 12 months before failure and large elevations 3 months before failure.Conclusions: Replacement of cochlear implants in pediatric patients is common and is due to device malfunction about one half of the time. Earlier initial channel fault, earlier subsequent channel faults, adjacent channel faults, and a greater total number of channel faults were associated with the need for replacement surgery. Elevations in a channel's impedance should raise the concern for an impending failure. These predictors can help the cochlear implant team when considering surgery to replace the device. Laryngoscope, 2010
- 30 November 2009
- Published by Wiley in The Laryngoscope
- Vol. 120 (2) , 399-404
Open AccessCharacteristics of malfunctioning channels in pediatric cochlear implants
Objectives/Hypothesis: To examine the characteristics of pediatric cochlear implant channel malfunction preceding device failure.Study Design: Retrospective review.Methods: All pediatric patients who underwent cochlear implantation at a tertiary academic medical center were reviewed regarding device type, reason for replacement, time to replacement, and timing and pattern of channel faults in failed versus nonfailed devices.Results: Between 1993 and 2008, 264 pediatric cochlear implantations were performed. With an average 894‐day follow‐up, the replacement rate was 9.5% (25/264). Reasons for replacement were device failure (6.4%), medical/surgical failure (2.3%), and obsolescence (0.8%). Replacement rates were comparable among Advanced Bionics (13.3%), Cochlear Corporation (6.3%), and MED‐EL (10.3%) devices. Fifty‐two cochlear implants developed at least one channel fault, and 13 eventually progressed to failure requiring replacement. MED‐EL devices comprised 12 of these 13 failures. At the 12‐month follow‐up interval, one, three, and five channel faults predicted 40%, 75%, and 100% probabilities of eventual electrode failure, respectively. Channels destined to fail demonstrated small, yet statistically significant, impedance elevations 12 months before failure and large elevations 3 months before failure.Conclusions: Replacement of cochlear implants in pediatric patients is common and is due to device malfunction about one half of the time. Earlier initial channel fault, earlier subsequent channel faults, adjacent channel faults, and a greater total number of channel faults were associated with the need for replacement surgery. Elevations in a channel's impedance should raise the concern for an impending failure. These predictors can help the cochlear implant team when considering surgery to replace the device. Laryngoscope, 2010