Mohan Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohan Jin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Nan Peng
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
4 shared publications - Peng Zhang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
4 shared publications - Rui Liang
China University of Mining and Technology
4 shared publications - Meng Hou
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
3 shared publications - Jian Li
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications - Lihua Xu
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
2 shared publications
Latest Publications
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 74-86
Incipient Fault Detection of Medium-Voltage Distribution Cable Systems Using Time-Frequency Analysis of Grounding Wire Currents
Incipient cable faults pose a significant risk to the normal operation of power grids. Addressing the issue of detecting incipient faults in underground cables is particularly difficult due to their hidden external characteristics that are not easily observable. Furthermore, these faults occur randomly, with short durations, which further complicates their detection. This paper firstly establishes a cable field-circuit equivalent model that considers multi-conductor electromagnetic coupling for incipient faulty scenarios. The mathematical relationship between the grounding wire currents (GWCs) and fault conditions is then theoretically deduced specifically. A novel method is developed to detect incipient faults in three-core cables by analyzing the time-frequency characteristics of GWC frequency components considering the time-varying fault resistance. The simulation results demonstrate the effectiveness and robustness of the proposed method, showing little impact from fault initial conditions, disturbances, and distributed generations (DGs). Finally, the method is verified in an actual 10 kV distribution network.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 74-86
Incipient Fault Detection of Medium-Voltage Distribution Cable Systems Using Time-Frequency Analysis of Grounding Wire Currents
Incipient cable faults pose a significant risk to the normal operation of power grids. Addressing the issue of detecting incipient faults in underground cables is particularly difficult due to their hidden external characteristics that are not easily observable. Furthermore, these faults occur randomly, with short durations, which further complicates their detection. This paper firstly establishes a cable field-circuit equivalent model that considers multi-conductor electromagnetic coupling for incipient faulty scenarios. The mathematical relationship between the grounding wire currents (GWCs) and fault conditions is then theoretically deduced specifically. A novel method is developed to detect incipient faults in three-core cables by analyzing the time-frequency characteristics of GWC frequency components considering the time-varying fault resistance. The simulation results demonstrate the effectiveness and robustness of the proposed method, showing little impact from fault initial conditions, disturbances, and distributed generations (DGs). Finally, the method is verified in an actual 10 kV distribution network.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 7634-7645
Distance Estimation for Early Three-Core Cable Fault Based on Multiple Amplitude Ratio Fusion of Grounding Line Current Selected Frequency Band
Early cable faults are becoming more prevalent in urban distribution networks. In this paper, the mechanism of grounding line current signal generation and propagation in cables with early faults is analyzed to help understand the relationship among each frequency component, the fault location, and fault resistance, based on which we propose a novel distance estimation method for early faults in three-core cables using multiple amplitude ratio fusion within a selected frequency band. By combining the amplitudes of different frequency components, this approach reduces the reliance on accurate extraction of the amplitude of a single-frequency component, which is particularly suitable for detecting sub-cycle early faults. Simulation analysis and field test results demonstrate the proposed method's high accuracy in estimating the fault distance. Moreover, it is less susceptible to variations in fault conditions. These findings show that the proposed method is effective in addressing the challenge of early cable fault distance estimation in distribution networks.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (5) , 7634-7645
Distance Estimation for Early Three-Core Cable Fault Based on Multiple Amplitude Ratio Fusion of Grounding Line Current Selected Frequency Band
Early cable faults are becoming more prevalent in urban distribution networks. In this paper, the mechanism of grounding line current signal generation and propagation in cables with early faults is analyzed to help understand the relationship among each frequency component, the fault location, and fault resistance, based on which we propose a novel distance estimation method for early faults in three-core cables using multiple amplitude ratio fusion within a selected frequency band. By combining the amplitudes of different frequency components, this approach reduces the reliance on accurate extraction of the amplitude of a single-frequency component, which is particularly suitable for detecting sub-cycle early faults. Simulation analysis and field test results demonstrate the proposed method's high accuracy in estimating the fault distance. Moreover, it is less susceptible to variations in fault conditions. These findings show that the proposed method is effective in addressing the challenge of early cable fault distance estimation in distribution networks.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (8) , 10473-10487
Fault Detection of the Medium-Voltage DC Cable by Using the Featured Modal Signals
The insulation of the medium-voltage direct current (MVdc) cable is prone to deterioration due to external and internal factors, which may lead to faults. Aiming to accommodate two different cable operation modes, in this article, the feasibility of decoupling transient measurements is first verified. An algorithm is presented for calculating the phase-mode transformation matrices used for signal decoupling. Then, the states of decoupled modal signals are analyzed to select the featured ones that reflect fault occurrence. A fault detection method is proposed based on the variation characteristics of featured modal signals. Finally, the experimental model of the MVdc cables is created using real-time digital simulation. The experimental results show that the method is independent of the fault condition, cable length, and operating mode. The average fault detection accuracy exceeds 99% with noises equal to or larger than 20 dB. The method applies to a wide range of fault resistances (1–3000 Ω).
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (8) , 10473-10487
Fault Detection of the Medium-Voltage DC Cable by Using the Featured Modal Signals
The insulation of the medium-voltage direct current (MVdc) cable is prone to deterioration due to external and internal factors, which may lead to faults. Aiming to accommodate two different cable operation modes, in this article, the feasibility of decoupling transient measurements is first verified. An algorithm is presented for calculating the phase-mode transformation matrices used for signal decoupling. Then, the states of decoupled modal signals are analyzed to select the featured ones that reflect fault occurrence. A fault detection method is proposed based on the variation characteristics of featured modal signals. Finally, the experimental model of the MVdc cables is created using real-time digital simulation. The experimental results show that the method is independent of the fault condition, cable length, and operating mode. The average fault detection accuracy exceeds 99% with noises equal to or larger than 20 dB. The method applies to a wide range of fault resistances (1–3000 Ω).
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (5) , 7708-7718
Faulty Cable Segment Identification of Low-Resistance Grounded Active Distributions via Grounding Wire Current-Based Approach
Faults in underground cables are hard to be detected directly from external features such as sound and light due to the harsh operating environment. Moreover, the rising penetration of distributed generations further complicates the characteristics of cable faults. Facing the challenges, this article first aims to reveal cable fault features via analyzing the generation mechanism of the cable grounding wire current (GWC). The impact of photovoltaic on GWC is then discussed, and the essential differences between faulty and healthy cables are also studied. Finally, considering both the structure of distribution network and an optimal deployment of measurement points, a novel fault cable segment identification method based on the amplitude and polarity of the starting terminal GWC steady-state variation is proposed. Simulations based on a real low-resistance grounded distribution network are performed in diverse fault scenarios and show a near 100% accuracy for all cases. In addition, the proposed method demonstrated a time complexity of O (896), showing a significant reduction in calculation time compared to common methods. These findings suggest that the proposed method is highly reliable and efficient for identifying faulty cable segments in active distribution networks.
- 23 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (5) , 7708-7718
Faulty Cable Segment Identification of Low-Resistance Grounded Active Distributions via Grounding Wire Current-Based Approach
Faults in underground cables are hard to be detected directly from external features such as sound and light due to the harsh operating environment. Moreover, the rising penetration of distributed generations further complicates the characteristics of cable faults. Facing the challenges, this article first aims to reveal cable fault features via analyzing the generation mechanism of the cable grounding wire current (GWC). The impact of photovoltaic on GWC is then discussed, and the essential differences between faulty and healthy cables are also studied. Finally, considering both the structure of distribution network and an optimal deployment of measurement points, a novel fault cable segment identification method based on the amplitude and polarity of the starting terminal GWC steady-state variation is proposed. Simulations based on a real low-resistance grounded distribution network are performed in diverse fault scenarios and show a near 100% accuracy for all cases. In addition, the proposed method demonstrated a time complexity of O (896), showing a significant reduction in calculation time compared to common methods. These findings suggest that the proposed method is highly reliable and efficient for identifying faulty cable segments in active distribution networks.