David Viar-Hernandez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Viar-Hernandez has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Angel Torrado-Carvajal
Universidad Rey Juan Carlos Medical Image Analysis and Biometry Laboratory Madrid Spain
5 shared publications - Borja Rodriguez-Vila
Universidad Rey Juan Carlos Medical Image Analysis and Biometry Laboratory Madrid Spain
5 shared publications - Norberto Malpica
Medical Image Analysis and Biometry Lab, Universidad Rey Juan Carlos, Madrid, Spain
4 shared publications - Juan Antonio Vera-Sánchez
Hospital Universitari Sant Joan de Reus
3 shared publications - Juan Manuel Molina-Maza
Universidad Rey Juan Carlos Medical Image Analysis and Biometry Laboratory Madrid Spain
3 shared publications - Alejandro Mazal
Centro de Protonterapia Quironsalud, Madrid, SPAIN
2 shared publications
Latest Publications
- 8 November 2024
- Published by Wiley in Medical Physics
- Vol. 52 (2) , 847-855
Deep learning based apparent diffusion coefficient map generation from multi‐parametric MR images for patients with diffuse gliomas
Purpose: Apparent diffusion coefficient (ADC) maps derived from diffusion weighted magnetic resonance imaging (DWI MRI) provides functional measurements about the water molecules in tissues. However, DWI is time consuming and very susceptible to image artifacts, leading to inaccurate ADC measurements. This study aims to develop a deep learning framework to synthesize ADC maps from multi‐parametric MR images.Methods: We proposed the multiparametric residual vision transformer model (MPR‐ViT) that leverages the long‐range context of vision transformer (ViT) layers along with the precision of convolutional operators. Residual blocks throughout the network significantly increasing the representational power of the model. The MPR‐ViT model was applied to T1w and T2‐fluid attenuated inversion recovery images of 501 glioma cases from a publicly available dataset including preprocessed ADC maps. Selected patients were divided into training (N = 400), validation (N = 50), and test (N = 51) sets, respectively. Using the preprocessed ADC maps as ground truth, model performance was evaluated and compared against the Vision Convolutional Transformer (VCT) and residual vision transformer (ResViT) models with the peak signal‐to‐noise ratio (PSNR), structural similarity index measure (SSIM), and mean squared error (MSE).Results: The results are as follows using T1w + T2‐FLAIR MRI as inputs: MPR‐ViT—PSNR: 31.0 ± 2.1, MSE: 0.009 ± 0.0005, SSIM: 0.950 ± 0.015. In addition, ablation studies showed the relative impact on performance of each input sequence. Both qualitative and quantitative results indicate that the proposed MR‐ViT model performs favorably against the ground truth data.Conclusion: We show that high‐quality ADC maps can be synthesized from structural MRI using a MPR‐ViT model. Our predicted images show better conformality to the ground truth volume than ResViT and VCT predictions. These high‐quality synthetic ADC maps would be particularly useful for disease diagnosis and intervention, especially when ADC maps have artifacts or are unavailable.
- 8 November 2024
- Published by Wiley in Medical Physics
- Vol. 52 (2) , 847-855
Deep learning based apparent diffusion coefficient map generation from multi‐parametric MR images for patients with diffuse gliomas
Purpose: Apparent diffusion coefficient (ADC) maps derived from diffusion weighted magnetic resonance imaging (DWI MRI) provides functional measurements about the water molecules in tissues. However, DWI is time consuming and very susceptible to image artifacts, leading to inaccurate ADC measurements. This study aims to develop a deep learning framework to synthesize ADC maps from multi‐parametric MR images.Methods: We proposed the multiparametric residual vision transformer model (MPR‐ViT) that leverages the long‐range context of vision transformer (ViT) layers along with the precision of convolutional operators. Residual blocks throughout the network significantly increasing the representational power of the model. The MPR‐ViT model was applied to T1w and T2‐fluid attenuated inversion recovery images of 501 glioma cases from a publicly available dataset including preprocessed ADC maps. Selected patients were divided into training (N = 400), validation (N = 50), and test (N = 51) sets, respectively. Using the preprocessed ADC maps as ground truth, model performance was evaluated and compared against the Vision Convolutional Transformer (VCT) and residual vision transformer (ResViT) models with the peak signal‐to‐noise ratio (PSNR), structural similarity index measure (SSIM), and mean squared error (MSE).Results: The results are as follows using T1w + T2‐FLAIR MRI as inputs: MPR‐ViT—PSNR: 31.0 ± 2.1, MSE: 0.009 ± 0.0005, SSIM: 0.950 ± 0.015. In addition, ablation studies showed the relative impact on performance of each input sequence. Both qualitative and quantitative results indicate that the proposed MR‐ViT model performs favorably against the ground truth data.Conclusion: We show that high‐quality ADC maps can be synthesized from structural MRI using a MPR‐ViT model. Our predicted images show better conformality to the ground truth volume than ResViT and VCT predictions. These high‐quality synthetic ADC maps would be particularly useful for disease diagnosis and intervention, especially when ADC maps have artifacts or are unavailable.
- Open Access
- 18 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215011
Exploring dual energy CT synthesis in CBCT-based adaptive radiotherapy and proton therapy: application of denoising diffusion probabilistic models
Background. Adaptive radiotherapy (ART) requires precise tissue characterization to optimize treatment plans and enhance the efficacy of radiation delivery while minimizing exposure to organs at risk. Traditional imaging techniques such as cone beam computed tomography (CBCT) used in ART settings often lack the resolution and detail necessary for accurate dosimetry, especially in proton therapy. Purpose. This study aims to enhance ART by introducing an innovative approach that synthesizes dual-energy computed tomography (DECT) images from CBCT scans using a novel 3D conditional denoising diffusion probabilistic model (DDPM) multi-decoder. This method seeks to improve dose calculations in ART planning, enhancing tissue characterization. Methods. We utilized a paired CBCT-DECT dataset from 54 head and neck cancer patients to train and validate our DDPM model. The model employs a multi-decoder Swin-UNET architecture that synthesizes high-resolution DECT images by progressively reducing noise and artifacts in CBCT scans through a controlled diffusion process. Results. The proposed method demonstrated superior performance in synthesizing DECT images (High DECT MAE 39.582 ± 0.855 and Low DECT MAE 48.540± 1.833) with significantly enhanced signal-to-noise ratio and reduced artifacts compared to traditional GAN-based methods. It showed marked improvements in tissue characterization and anatomical structure similarity, critical for precise proton and radiation therapy planning. Conclusions. This research has opened a new avenue in CBCT-CT synthesis for ART/APT by generating DECT images using an enhanced DDPM approach. The demonstrated similarity between the synthesized DECT images and ground truth images suggests that these synthetic volumes can be used for accurate dose calculations, leading to better adaptation in treatment planning.
- 18 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215011
Open AccessExploring dual energy CT synthesis in CBCT-based adaptive radiotherapy and proton therapy: application of denoising diffusion probabilistic models
Background. Adaptive radiotherapy (ART) requires precise tissue characterization to optimize treatment plans and enhance the efficacy of radiation delivery while minimizing exposure to organs at risk. Traditional imaging techniques such as cone beam computed tomography (CBCT) used in ART settings often lack the resolution and detail necessary for accurate dosimetry, especially in proton therapy. Purpose. This study aims to enhance ART by introducing an innovative approach that synthesizes dual-energy computed tomography (DECT) images from CBCT scans using a novel 3D conditional denoising diffusion probabilistic model (DDPM) multi-decoder. This method seeks to improve dose calculations in ART planning, enhancing tissue characterization. Methods. We utilized a paired CBCT-DECT dataset from 54 head and neck cancer patients to train and validate our DDPM model. The model employs a multi-decoder Swin-UNET architecture that synthesizes high-resolution DECT images by progressively reducing noise and artifacts in CBCT scans through a controlled diffusion process. Results. The proposed method demonstrated superior performance in synthesizing DECT images (High DECT MAE 39.582 ± 0.855 and Low DECT MAE 48.540± 1.833) with significantly enhanced signal-to-noise ratio and reduced artifacts compared to traditional GAN-based methods. It showed marked improvements in tissue characterization and anatomical structure similarity, critical for precise proton and radiation therapy planning. Conclusions. This research has opened a new avenue in CBCT-CT synthesis for ART/APT by generating DECT images using an enhanced DDPM approach. The demonstrated similarity between the synthesized DECT images and ground truth images suggests that these synthetic volumes can be used for accurate dose calculations, leading to better adaptation in treatment planning.
- Open Access
- 28 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4655
CycleGAN-Driven MR-Based Pseudo-CT Synthesis for Knee Imaging Studies
In the field of knee imaging, the incorporation of MR-based pseudo-CT synthesis holds the potential to mitigate the need for separate CT scans, simplifying workflows, enhancing patient comfort, and reducing radiation exposure. In this work, we present a novel DL framework, grounded in the development of the Cycle-Consistent Generative Adversarial Network (CycleGAN) method, tailored specifically for the synthesis of pseudo-CT images in knee imaging to surmount the limitations of current methods. Upon visually examining the outcomes, it is evident that the synthesized pseudo-CTs show an excellent quality and high robustness. Despite the limited dataset employed, the method is able to capture the particularities of the bone contours in the resulting image. The experimental Mean Absolute Error (MAE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Zero-Normalized Cross Correlation (ZNCC), Mutual Information (MI), Relative Change (RC), and absolute Relative Change (|RC|) report values of 30.4638 ± 7.4770, 28.1168 ± 1.5245, 0.9230 ± 0.0217, 0.9807 ± 0.0071, 0.8548 ± 0.1019, 0.0055 ± 0.0265, and 0.0302 ± 0.0218 (median ± median absolute deviation), respectively. The voxel-by-voxel correlation plot shows an excellent correlation between pseudo-CT and ground-truth CT Hounsfield units (m = 0.9785; adjusted = 0.9988; = 0.9849; p < 0.001). The Bland–Altman plot shows that the average of the differences is low (( = 0.7199 ± 35.2490; 95% confidence interval [−68.3681, 69.8079]). This study represents the first reported effort in the field of MR-based knee pseudo-CT synthesis, shedding light to significantly advance the field of knee imaging.- 28 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (11) , 4655
Open AccessCycleGAN-Driven MR-Based Pseudo-CT Synthesis for Knee Imaging Studies
In the field of knee imaging, the incorporation of MR-based pseudo-CT synthesis holds the potential to mitigate the need for separate CT scans, simplifying workflows, enhancing patient comfort, and reducing radiation exposure. In this work, we present a novel DL framework, grounded in the development of the Cycle-Consistent Generative Adversarial Network (CycleGAN) method, tailored specifically for the synthesis of pseudo-CT images in knee imaging to surmount the limitations of current methods. Upon visually examining the outcomes, it is evident that the synthesized pseudo-CTs show an excellent quality and high robustness. Despite the limited dataset employed, the method is able to capture the particularities of the bone contours in the resulting image. The experimental Mean Absolute Error (MAE), Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Zero-Normalized Cross Correlation (ZNCC), Mutual Information (MI), Relative Change (RC), and absolute Relative Change (|RC|) report values of 30.4638 ± 7.4770, 28.1168 ± 1.5245, 0.9230 ± 0.0217, 0.9807 ± 0.0071, 0.8548 ± 0.1019, 0.0055 ± 0.0265, and 0.0302 ± 0.0218 (median ± median absolute deviation), respectively. The voxel-by-voxel correlation plot shows an excellent correlation between pseudo-CT and ground-truth CT Hounsfield units (m = 0.9785; adjusted = 0.9988; = 0.9849; p < 0.001). The Bland–Altman plot shows that the average of the differences is low (( = 0.7199 ± 35.2490; 95% confidence interval [−68.3681, 69.8079]). This study represents the first reported effort in the field of MR-based knee pseudo-CT synthesis, shedding light to significantly advance the field of knee imaging. - Open Access
- 3 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (7) , 4922-4935
Enhancing adaptive proton therapy through CBCT images: Synthetic head and neck CT generation based on 3D vision transformers
Background: Proton therapy is a form of radiotherapy commonly used to treat various cancers. Due to its high conformality, minor variations in patient anatomy can lead to significant alterations in dose distribution, making adaptation crucial. While cone‐beam computed tomography (CBCT) is a well‐established technique for adaptive radiation therapy (ART), it cannot be directly used for adaptive proton therapy (APT) treatments because the stopping power ratio (SPR) cannot be estimated from CBCT images.Purpose: To address this limitation, Deep Learning methods have been suggested for converting pseudo‐CT (pCT) images from CBCT images. In spite of convolutional neural networks (CNNs) have shown consistent improvement in pCT literature, there is still a need for further enhancements to make them suitable for clinical applications.Methods: The authors introduce the 3D vision transformer (ViT) block, studying its performance at various stages of the proposed architectures. Additionally, they conduct a retrospective analysis of a dataset that includes 259 image pairs from 59 patients who underwent treatment for head and neck cancer. The dataset is partitioned into 80% for training, 10% for validation, and 10% for testing purposes.Results: The SPR maps obtained from the pCT using the proposed method present an absolute relative error of less than 5% from those computed from the planning CT, thus improving the results of CBCT.Conclusions: We introduce an enhanced ViT3D architecture for pCT image generation from CBCT images, reducing SPR error within clinical margins for APT workflows. The new method minimizes bias compared to CT‐based SPR estimation and dose calculation, signaling a promising direction for future research in this field. However, further research is needed to assess the robustness and generalizability across different medical imaging applications.
- 3 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (7) , 4922-4935
Open AccessEnhancing adaptive proton therapy through CBCT images: Synthetic head and neck CT generation based on 3D vision transformers
Background: Proton therapy is a form of radiotherapy commonly used to treat various cancers. Due to its high conformality, minor variations in patient anatomy can lead to significant alterations in dose distribution, making adaptation crucial. While cone‐beam computed tomography (CBCT) is a well‐established technique for adaptive radiation therapy (ART), it cannot be directly used for adaptive proton therapy (APT) treatments because the stopping power ratio (SPR) cannot be estimated from CBCT images.Purpose: To address this limitation, Deep Learning methods have been suggested for converting pseudo‐CT (pCT) images from CBCT images. In spite of convolutional neural networks (CNNs) have shown consistent improvement in pCT literature, there is still a need for further enhancements to make them suitable for clinical applications.Methods: The authors introduce the 3D vision transformer (ViT) block, studying its performance at various stages of the proposed architectures. Additionally, they conduct a retrospective analysis of a dataset that includes 259 image pairs from 59 patients who underwent treatment for head and neck cancer. The dataset is partitioned into 80% for training, 10% for validation, and 10% for testing purposes.Results: The SPR maps obtained from the pCT using the proposed method present an absolute relative error of less than 5% from those computed from the planning CT, thus improving the results of CBCT.Conclusions: We introduce an enhanced ViT3D architecture for pCT image generation from CBCT images, reducing SPR error within clinical margins for APT workflows. The new method minimizes bias compared to CT‐based SPR estimation and dose calculation, signaling a promising direction for future research in this field. However, further research is needed to assess the robustness and generalizability across different medical imaging applications.
- Open Access
A case study of medical image software evolution and its impact in the medical imaging community
- Open Access
- 9 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (4) , 045018
Material decomposition maps based calibration of dual energy CT scanners for proton therapy planning: a phantom study
We introduce a new calibration method for dual energy CT (DECT) based on material decomposition (MD) maps, specifically iodine and water MD maps. The aim of this method is to provide the first DECT calibration based on MD maps. The experiments were carried out using a general electric (GE) revolution CT scanner with ultra-fast kV switching and used a density phantom by GAMMEX for calibration and evaluation. The calibration process involves several steps. First, we tested the ability of MD values to reproduce Hounsfield unit (HU) values of single energy CT (SECT) acquisitions and it was found that the errors were below 1%, validating their use for HU reproduction. Next, the different definitions of computed Z values were compared and the robustness of the approach based on the materials’ composition was confirmed. Finally, the calibration method was compared with a previous method by Bourque et al , providing a similar level of accuracy and superior performance in terms of precision. Overall, this novel DECT calibration method offers improved accuracy and reliability in determining tissue-specific physical properties. The resulting maps can be valuable for proton therapy treatments, where precise dose calculations and accurate tissue differentiation are crucial for optimal treatment planning and delivery.
- 9 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (4) , 045018
Open AccessMaterial decomposition maps based calibration of dual energy CT scanners for proton therapy planning: a phantom study
We introduce a new calibration method for dual energy CT (DECT) based on material decomposition (MD) maps, specifically iodine and water MD maps. The aim of this method is to provide the first DECT calibration based on MD maps. The experiments were carried out using a general electric (GE) revolution CT scanner with ultra-fast kV switching and used a density phantom by GAMMEX for calibration and evaluation. The calibration process involves several steps. First, we tested the ability of MD values to reproduce Hounsfield unit (HU) values of single energy CT (SECT) acquisitions and it was found that the errors were below 1%, validating their use for HU reproduction. Next, the different definitions of computed Z values were compared and the robustness of the approach based on the materials’ composition was confirmed. Finally, the calibration method was compared with a previous method by Bourque et al , providing a similar level of accuracy and superior performance in terms of precision. Overall, this novel DECT calibration method offers improved accuracy and reliability in determining tissue-specific physical properties. The resulting maps can be valuable for proton therapy treatments, where precise dose calculations and accurate tissue differentiation are crucial for optimal treatment planning and delivery.