Rukiye Taşdemir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rukiye Taşdemir has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kerim Yapici
Department of Chemical Engineering, Suleyman Demirel University, Isparta, Turkey
2 shared publications - Ümran Sofu
Department of Analytical Chemistry, Faculty of Pharmacy, Süleyman Demirel University, Isparta, Türkiye
2 shared publications - Buse Akkaya
Süleyman Demirel University
1 shared publication - Ceren Poyraz
Department of Chemical Engineering, Faculty of Engineering and Natural Sciences, Süleyman Demirel University, Isparta, Turkiye
1 shared publication - Ebru Çubuk Demiralay
Süleyman Demirel University
1 shared publication - Ebru Önem
Süleyman Demirel Üniversitesi
1 shared publication
Latest Publications
- 18 November 2026
- Published by Springer Nature in Food Analytical Methods
- Vol. 19 (12)
Development of a Sustainable and Low-Cost Voltammetric Method for the Determination of Doxycycline in Milk Samples
- 18 November 2026
- Published by Springer Nature in Food Analytical Methods
- Vol. 19 (12)
Development of a Sustainable and Low-Cost Voltammetric Method for the Determination of Doxycycline in Milk Samples
- Open Access
- 16 October 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 50 (5) , 554-569
Effects of washing, oxidation, carboxylation, and hydrophobicity on the antibacterial activity of graphene oxide and reduced graphene oxide
In this study, the effects of number of washes, oxidation degree, carboxylation, and hydrothermal reduction temperature on the antibacterial activity of graphene oxide (GO) and reduced graphene oxide (rGO) nanomaterials were investigated. GO derivatives with different numbers of washes (1–5W) and oxidation levels (3X, 6X, and 9X), carboxylated GO (GO-COOH), and rGO samples obtained at different hydrothermal reduction temperatures (100, 140, and 180 °C) were characterized by X-ray diffraction, field-emission scanning electron microscopy, Fourier-transform infrared spectroscopy, zeta potential analysis, and Raman spectroscopy, and were subsequently evaluated for antibacterial activity against gram-positive Staphylococcus aureus (S. aureus) and gram-negative Escherichia coli (E. coli). The washing experiments showed that, in the presence of residual acids (1W), a 5-log reduction was achieved for S. aureus at 600 μg/mL, whereas after acid removal (5W), purified GO produced a 2-log reduction at the same concentration. In contrast, no meaningful change in activity was observed for E. coli as a function of number of washes (~1 log). In the oxidation optimization experiments, the 6X oxidation level yielded the highest antibacterial efficacy against S. aureus, producing a 5-log reduction at 800 μg/mL, while excessive oxidation (9X) led to a plateau in activity because of structural defects. Carboxylation decreased activity against S. aureus by 40% at 800 μg/mL (from 5 log to 3 log) because of electrostatic repulsion, while leaving the already low activity against E. coli (~1 log) unchanged. In the hydrothermal reduction experiments, partial reduction at 100 °C produced the optimal hydrophilic–hydrophobic balance for S. aureus (3-log reduction at 240 μg/mL), whereas the higher hydrophobicity at 180 °C enabled effective inhibition of E. coli (2- to 3-log reduction at 180–240 μg/mL). These findings show that antibacterial efficacy depends on the compatibility between surface chemical properties and bacterial cell-wall structure.
- 16 October 2026
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 50 (5) , 554-569
Open AccessEffects of washing, oxidation, carboxylation, and hydrophobicity on the antibacterial activity of graphene oxide and reduced graphene oxide
In this study, the effects of number of washes, oxidation degree, carboxylation, and hydrothermal reduction temperature on the antibacterial activity of graphene oxide (GO) and reduced graphene oxide (rGO) nanomaterials were investigated. GO derivatives with different numbers of washes (1–5W) and oxidation levels (3X, 6X, and 9X), carboxylated GO (GO-COOH), and rGO samples obtained at different hydrothermal reduction temperatures (100, 140, and 180 °C) were characterized by X-ray diffraction, field-emission scanning electron microscopy, Fourier-transform infrared spectroscopy, zeta potential analysis, and Raman spectroscopy, and were subsequently evaluated for antibacterial activity against gram-positive Staphylococcus aureus (S. aureus) and gram-negative Escherichia coli (E. coli). The washing experiments showed that, in the presence of residual acids (1W), a 5-log reduction was achieved for S. aureus at 600 μg/mL, whereas after acid removal (5W), purified GO produced a 2-log reduction at the same concentration. In contrast, no meaningful change in activity was observed for E. coli as a function of number of washes (~1 log). In the oxidation optimization experiments, the 6X oxidation level yielded the highest antibacterial efficacy against S. aureus, producing a 5-log reduction at 800 μg/mL, while excessive oxidation (9X) led to a plateau in activity because of structural defects. Carboxylation decreased activity against S. aureus by 40% at 800 μg/mL (from 5 log to 3 log) because of electrostatic repulsion, while leaving the already low activity against E. coli (~1 log) unchanged. In the hydrothermal reduction experiments, partial reduction at 100 °C produced the optimal hydrophilic–hydrophobic balance for S. aureus (3-log reduction at 240 μg/mL), whereas the higher hydrophobicity at 180 °C enabled effective inhibition of E. coli (2- to 3-log reduction at 180–240 μg/mL). These findings show that antibacterial efficacy depends on the compatibility between surface chemical properties and bacterial cell-wall structure.
- Open Access
- 29 June 2024
- Published by Open Journal of Nano in Open Journal of Nano
- Vol. 9 (1) , 1-10
Colloidal Silica Production with Resin from Sodium Silicate and Optimization of Process
Colloidal silica is a stable and homogeneously dispersed form of amorphous silicon dioxide (SiO2) nanoparticles in water. Colloidal silica has been the focus of research due to large surface area, biocompatibility, low toxicity and chemical and thermal stability. It has been used in a wide variety of industrial applications, including pulp and paper, chromatography, electronics, foods, and colloids, as well as in the ceramics and glass industry. In this study, colloidal silica was produced using cationic resin and sodium silicate and process conditions were optimized. Temperature (50-80 °C), mixing speed (200-500 rpm) and time (20-120 min.), which significantly affect the particle size, were selected as parameters. Particle size distribution (PSD) analyzes of colloidal silica particles were performed to determine appropriate levels of the parameters. The most suitable process conditions are 50°C temperature, 40 min. and 300 rpm. The average particle size of colloidal silica produced in optimum conditions was measured as 80 nm.
- 29 June 2024
- Published by Open Journal of Nano in Open Journal of Nano
- Vol. 9 (1) , 1-10
Open AccessColloidal Silica Production with Resin from Sodium Silicate and Optimization of Process
Colloidal silica is a stable and homogeneously dispersed form of amorphous silicon dioxide (SiO2) nanoparticles in water. Colloidal silica has been the focus of research due to large surface area, biocompatibility, low toxicity and chemical and thermal stability. It has been used in a wide variety of industrial applications, including pulp and paper, chromatography, electronics, foods, and colloids, as well as in the ceramics and glass industry. In this study, colloidal silica was produced using cationic resin and sodium silicate and process conditions were optimized. Temperature (50-80 °C), mixing speed (200-500 rpm) and time (20-120 min.), which significantly affect the particle size, were selected as parameters. Particle size distribution (PSD) analyzes of colloidal silica particles were performed to determine appropriate levels of the parameters. The most suitable process conditions are 50°C temperature, 40 min. and 300 rpm. The average particle size of colloidal silica produced in optimum conditions was measured as 80 nm.
- 19 October 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (7) , 6287-6301
Optimization of Lead (II) Adsorption onto Cross-Linked Polycarboxylate-Based Adsorbent by Response Surface Methodology
- 19 October 2020
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (7) , 6287-6301
Optimization of Lead (II) Adsorption onto Cross-Linked Polycarboxylate-Based Adsorbent by Response Surface Methodology