Svea Steuer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Svea Steuer has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Edmund Koch
Clinical Sensoring and Monitoring, Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, TU Dresden, Dresden, Germany
3 shared publications - Jonas Golde
Fraunhofer Institute for Material and Beam Technology IWS, Dresden , Germany
3 shared publications - Joseph Morgenstern
Department of Otorhinolaryngology, Head and Neck Surgery, Ear Research Center Dresden, Technische Universität Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, Dresden, Germany
3 shared publications Lars Kirsten
TU Dresden, Faculty of Medicine Carl Gustav Carus, Medical Physics and Biomedical Engineering, Fetscherstrasse 74, 01307 Dresden, Germany
2 shared publications- Lars Kirsten
Universitätsklinikum Carl Gustav Carus Dresden (Germany)
2 shared publications - Marcus Neudert
Department of Otorhinolaryngology Head and Neck Surgery, Faculty of Medicine and University Hospital Carl Gustav Carus, TU-Dresden, Dresden, Germany
2 shared publications
Latest Publications
- Open Access
- 9 December 2025
- Published by Springer Nature in Scientific Data
- Vol. 12 (1)
MEG-SCANS - A comprehensive magnetoencephalography speech dataset with Stories, Chirps and Noisy Sentences
Stories, Chirps, And Noisy Sentences (MEG-SCANS) is a dataset that provides raw magnetoencephalography (MEG) recordings from 24 German-speaking subjects. Each subject listened to approximately one hour of stimuli, including two audiobooks, sentences from the Oldenburger Matrix Sentence Test (OLSA) for Speech Reception Threshold (SRT) assessment, and short up-chirps used to assess MEG signal quality. The dataset includes MEG data, structural MRI (Magnetic Resonance Imaging) scans of the head, corresponding audio material (audiobooks, OLSA envelopes, and chirp stimuli), and behavioral audiogram and SRT results from hearing screenings. Organized according to the Brain Imaging Data Structure (BIDS), this resource offers a robust benchmark for large-scale encoding/decoding analyses of temporally-resolved brain responses to speech. Comprehensive Matlab and Python code are included to replicate key data validations, ensuring transparency and reproducibility.
- 9 December 2025
- Published by Springer Nature in Scientific Data
- Vol. 12 (1)
Open AccessMEG-SCANS - A comprehensive magnetoencephalography speech dataset with Stories, Chirps and Noisy Sentences
Stories, Chirps, And Noisy Sentences (MEG-SCANS) is a dataset that provides raw magnetoencephalography (MEG) recordings from 24 German-speaking subjects. Each subject listened to approximately one hour of stimuli, including two audiobooks, sentences from the Oldenburger Matrix Sentence Test (OLSA) for Speech Reception Threshold (SRT) assessment, and short up-chirps used to assess MEG signal quality. The dataset includes MEG data, structural MRI (Magnetic Resonance Imaging) scans of the head, corresponding audio material (audiobooks, OLSA envelopes, and chirp stimuli), and behavioral audiogram and SRT results from hearing screenings. Organized according to the Brain Imaging Data Structure (BIDS), this resource offers a robust benchmark for large-scale encoding/decoding analyses of temporally-resolved brain responses to speech. Comprehensive Matlab and Python code are included to replicate key data validations, ensuring transparency and reproducibility.
- 15 April 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (5) , 3018-3036
Visualization of carious lesions with polarized and depolarized light microscopy
Polarized light microscopy (PLM) is an established method in dental histology for investigating the ultrastructure and carious process of teeth. This study introduces a novel approach for measuring the degree of polarization (DOP) in a modified PLM setup and uses the DOP to assess the changes of the optical properties of enamel and dentin due to caries. The validation is provided by a comparison with complementary imaging methods, i.e. standard PLM and µCT. The results show that demineralization is reliably displayed by the DOP in accordance with the common imaging methods, and that this quantitative analysis of depolarization allows the characterization of the different pathohistological zones of caries.
- 15 April 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (5) , 3018-3036
Visualization of carious lesions with polarized and depolarized light microscopy
Polarized light microscopy (PLM) is an established method in dental histology for investigating the ultrastructure and carious process of teeth. This study introduces a novel approach for measuring the degree of polarization (DOP) in a modified PLM setup and uses the DOP to assess the changes of the optical properties of enamel and dentin due to caries. The validation is provided by a comparison with complementary imaging methods, i.e. standard PLM and µCT. The results show that demineralization is reliably displayed by the DOP in accordance with the common imaging methods, and that this quantitative analysis of depolarization allows the characterization of the different pathohistological zones of caries.
- Open Access
- 26 February 2024
- Published by Springer Nature in Scientific Data
- Vol. 11 (1) , 1-7
The Dresden in vivo OCT dataset for automatic middle ear segmentation
Endoscopic optical coherence tomography (OCT) offers a non-invasive approach to perform the morphological and functional assessment of the middle ear in vivo. However, interpreting such OCT images is challenging and time-consuming due to the shadowing of preceding structures. Deep neural networks have emerged as a promising tool to enhance this process in multiple aspects, including segmentation, classification, and registration. Nevertheless, the scarcity of annotated datasets of OCT middle ear images poses a significant hurdle to the performance of neural networks. We introduce the Dresden in vivo OCT Dataset of the Middle Ear (DIOME) featuring 43 OCT volumes from both healthy and pathological middle ears of 29 subjects. DIOME provides semantic segmentations of five crucial anatomical structures (tympanic membrane, malleus, incus, stapes and promontory), and sparse landmarks delineating the salient features of the structures. The availability of these data facilitates the training and evaluation of algorithms regarding various analysis tasks with middle ear OCT images, e.g. diagnostics.
- 26 February 2024
- Published by Springer Nature in Scientific Data
- Vol. 11 (1) , 1-7
Open AccessThe Dresden in vivo OCT dataset for automatic middle ear segmentation
Endoscopic optical coherence tomography (OCT) offers a non-invasive approach to perform the morphological and functional assessment of the middle ear in vivo. However, interpreting such OCT images is challenging and time-consuming due to the shadowing of preceding structures. Deep neural networks have emerged as a promising tool to enhance this process in multiple aspects, including segmentation, classification, and registration. Nevertheless, the scarcity of annotated datasets of OCT middle ear images poses a significant hurdle to the performance of neural networks. We introduce the Dresden in vivo OCT Dataset of the Middle Ear (DIOME) featuring 43 OCT volumes from both healthy and pathological middle ears of 29 subjects. DIOME provides semantic segmentations of five crucial anatomical structures (tympanic membrane, malleus, incus, stapes and promontory), and sparse landmarks delineating the salient features of the structures. The availability of these data facilitates the training and evaluation of algorithms regarding various analysis tasks with middle ear OCT images, e.g. diagnostics.
- Open Access
- 29 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 121203-15
In vivo microstructural investigation of the human tympanic membrane by endoscopic polarization-sensitive optical coherence tomography
Optical coherence tomography (OCT) is an interferometric imaging technique based on near-infrared light that enables real-time volumetric tissue imaging with microscopic resolution and penetration depths of up to 2 mm. While OCT has been successfully commercialized in ophthalmology for diagnostics of the eye, the application of both morphologic and functional OCT imaging for hearing diagnostics has attracted significant interest in recent years.1 This includes not only the tympanic membrane (TM)2,3 but also the ossicular chain in the middle ear4 – 6 and the inner ear.7,8
- 29 March 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (12) , 121203-15
Open AccessIn vivo microstructural investigation of the human tympanic membrane by endoscopic polarization-sensitive optical coherence tomography
Optical coherence tomography (OCT) is an interferometric imaging technique based on near-infrared light that enables real-time volumetric tissue imaging with microscopic resolution and penetration depths of up to 2 mm. While OCT has been successfully commercialized in ophthalmology for diagnostics of the eye, the application of both morphologic and functional OCT imaging for hearing diagnostics has attracted significant interest in recent years.1 This includes not only the tympanic membrane (TM)2,3 but also the ossicular chain in the middle ear4 – 6 and the inner ear.7,8
- Open Access
- 20 August 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 238, 04008
Imaging birefringent tissue in the human tympanic membrane by polarization-sensitive optical coherence tomography
Acousto-mechanical properties of the human tympanic membrane mainly depend on the connective tissue in its layered structure. Using polarization-sensitive optical coherence tomography, a depth-resolved imaging technique which provides additional tissue specific contrast, polarization changes of the birefringent layers in the human tympanic membrane were detected. By depicting estimated local retardances, distinguishing different tissue types was possible. This suggests the ability to image pathological alterations of the connective tissue with PSOCT, which extends the conventional diagnostic methods in middle ear surgery.
- 20 August 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 238, 04008
Open AccessImaging birefringent tissue in the human tympanic membrane by polarization-sensitive optical coherence tomography
Acousto-mechanical properties of the human tympanic membrane mainly depend on the connective tissue in its layered structure. Using polarization-sensitive optical coherence tomography, a depth-resolved imaging technique which provides additional tissue specific contrast, polarization changes of the birefringent layers in the human tympanic membrane were detected. By depicting estimated local retardances, distinguishing different tissue types was possible. This suggests the ability to image pathological alterations of the connective tissue with PSOCT, which extends the conventional diagnostic methods in middle ear surgery.