CVChristopher Vergara
Christopher Vergara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christopher Vergara has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Ferreira
Facultad de Medicina y Ciencia, Universidad San Sebastián, Santiago 7510602, Chile
1 shared publication - Apolo Salgado
IORT, Santiago 7500833, Chile
1 shared publication - Mauricio Santibáñez
Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile
1 shared publication - Melani Fuentealba
Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile
1 shared publication - Sergio Díez
Departamento de Fisiología, Universidad de Valencia, 46010 Valencia, Spain
1 shared publication
Latest Publications
- Open Access
- 27 February 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (5) , 430
An Optimized Method for Evaluating the Potential Gd-Nanoparticle Dose Enhancement Produced by Electronic Brachytherapy
This work reports an optimized method to experimentally quantify the Gd-nanoparticle dose enhancement generated by electronic brachytherapy. The dose enhancement was evaluated considering energy beams of 50 kVp and 70 kVp, determining the Gd-nanoparticle concentration ranges that would optimize the process for each energy. The evaluation was performed using delaminated radiochromic films and a Poly(methyl methacrylate) (PMMA) phantom covered on one side by a thin 2.5 m Mylar filter acting as an interface between the region with Gd suspension and the radiosensitive film substrate. The results for the 70 kVp beam quality showed dose increments of , , and at different concentrations of 10, 20, and 30 mg/mL, respectively, verifying the competitive mechanisms of enhancement and attenuation. For the 50 kVp beam quality, no increase in dose was recorded for the concentrations studied, indicating that the major contribution to enhancement is from the K-edge interaction. In order to separate the contributions of attenuation and enhancement to the total dose, measurements were replicated with a 12 m Mylar filter, obtaining a dose enhancement attributable to the K-edge of and at 20 and 30 mg/mL, respectively, evidencing a significant additional dose proportional to the Gd concentration.- 27 February 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (5) , 430
Open AccessAn Optimized Method for Evaluating the Potential Gd-Nanoparticle Dose Enhancement Produced by Electronic Brachytherapy
This work reports an optimized method to experimentally quantify the Gd-nanoparticle dose enhancement generated by electronic brachytherapy. The dose enhancement was evaluated considering energy beams of 50 kVp and 70 kVp, determining the Gd-nanoparticle concentration ranges that would optimize the process for each energy. The evaluation was performed using delaminated radiochromic films and a Poly(methyl methacrylate) (PMMA) phantom covered on one side by a thin 2.5 m Mylar filter acting as an interface between the region with Gd suspension and the radiosensitive film substrate. The results for the 70 kVp beam quality showed dose increments of , , and at different concentrations of 10, 20, and 30 mg/mL, respectively, verifying the competitive mechanisms of enhancement and attenuation. For the 50 kVp beam quality, no increase in dose was recorded for the concentrations studied, indicating that the major contribution to enhancement is from the K-edge interaction. In order to separate the contributions of attenuation and enhancement to the total dose, measurements were replicated with a 12 m Mylar filter, obtaining a dose enhancement attributable to the K-edge of and at 20 and 30 mg/mL, respectively, evidencing a significant additional dose proportional to the Gd concentration.