Lansa Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lansa Ding has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Congyan Chen
School of Automation, Southeast University, Nanjing, China
2 shared publications - Dezheng Wang
School of Automation, Southeast University, Nanjing 210096, People’s Republic of China
2 shared publications - Xiaoyi Wei
School of Automation, Southeast University, Jiangsu 210096, People’s Republic of China
2 shared publications - Liuqi Ma
School of Automation, Southeast University, Nanjing 210096, People’s Republic of China
1 shared publication
Latest Publications
- 28 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 096208
A lightweight complex-domain acoustic feature extraction method for rotating machinery fault detection
In the field of fault diagnosis for factory machinery systems, the development of deep learning methods has been hindered by the challenge of acquiring fault data, highlighting the need to extract noise robust features from limited labeled data. In this paper, a light and efficient complex-domain acoustic feature extraction method, complex-domain principal frequency convolution network (CPFCN) is proposed for fault diagnosis in rotating machinery, which consists of a principal frequency filter (PFF) and stacked convolution network (SCN). The PFF filters out non-principal frequency noise to focus on the predominant frequency. The SCN is designed to effectively extract the amplitude and phase features, which can fully leverage the complex-domain information within the acoustic data. The experimental results show that the proposed CPFCN have 33% increasing in accuracy while 87% reduction in training time and 41% reduction in feature extraction time. Additionally, the proposed framework has improved the accuracy by 59% on the dataset with noise compared to the best-performing method in the experimental study, achieving stronger noise robustness in the case of limited samples.
- 28 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 096208
A lightweight complex-domain acoustic feature extraction method for rotating machinery fault detection
In the field of fault diagnosis for factory machinery systems, the development of deep learning methods has been hindered by the challenge of acquiring fault data, highlighting the need to extract noise robust features from limited labeled data. In this paper, a light and efficient complex-domain acoustic feature extraction method, complex-domain principal frequency convolution network (CPFCN) is proposed for fault diagnosis in rotating machinery, which consists of a principal frequency filter (PFF) and stacked convolution network (SCN). The PFF filters out non-principal frequency noise to focus on the predominant frequency. The SCN is designed to effectively extract the amplitude and phase features, which can fully leverage the complex-domain information within the acoustic data. The experimental results show that the proposed CPFCN have 33% increasing in accuracy while 87% reduction in training time and 41% reduction in feature extraction time. Additionally, the proposed framework has improved the accuracy by 59% on the dataset with noise compared to the best-performing method in the experimental study, achieving stronger noise robustness in the case of limited samples.
- 7 March 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (6) , 066202
Construction of multi-features comprehensive indicator for machinery health state assessment
Health state assessment is critical for mechanical equipment’s smooth and healthy operation. This paper proposes a novel approach for health state assessment based on acoustic signals during the process of machinery running. It consists of multi-domain feature (MF) extraction and comprehensive health indicator (CHI) construction. MF is extracted from various acoustic features, including time and frequency (TF) features, mel-frequency cepstral coefficients, and gammatone frequency cepstral coefficients. The stacked long short-term memory (LSTM) is used to extract the high-level features of the MF, which are then input to the downstream PCA to obtain the LSTM-PCA health indicator (LP-HI). Parallelly, the MF is fed into the self-organizing mapping (SOM) model to calculate the minimum quantization error (MQE) as SOM-MQE health indicator (SM-HI). These two indicators are fused using weighted fusion and nonlinear mapping to calculate CHI. The experimental results on air compressor dataset show a 25.8% reduction in evaluation error compared with SOTA results in this paper. The proposed nonlinear mapping function furthermore reduces fitting error on HI by 38.9%. These demonstrate the effectiveness and superiority of the proposed method in machinery health state assessment.
- 7 March 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (6) , 066202
Construction of multi-features comprehensive indicator for machinery health state assessment
Health state assessment is critical for mechanical equipment’s smooth and healthy operation. This paper proposes a novel approach for health state assessment based on acoustic signals during the process of machinery running. It consists of multi-domain feature (MF) extraction and comprehensive health indicator (CHI) construction. MF is extracted from various acoustic features, including time and frequency (TF) features, mel-frequency cepstral coefficients, and gammatone frequency cepstral coefficients. The stacked long short-term memory (LSTM) is used to extract the high-level features of the MF, which are then input to the downstream PCA to obtain the LSTM-PCA health indicator (LP-HI). Parallelly, the MF is fed into the self-organizing mapping (SOM) model to calculate the minimum quantization error (MQE) as SOM-MQE health indicator (SM-HI). These two indicators are fused using weighted fusion and nonlinear mapping to calculate CHI. The experimental results on air compressor dataset show a 25.8% reduction in evaluation error compared with SOTA results in this paper. The proposed nonlinear mapping function furthermore reduces fitting error on HI by 38.9%. These demonstrate the effectiveness and superiority of the proposed method in machinery health state assessment.