Si Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Si Fu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chongyang Huang
Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
3 shared publications - Jing Li
Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
3 shared publications Chongyang Huang
College of Key Laboratory of Special Electric Machines and High Voltage Apparatus of Ministry of Education (Shenyang University of Technology)
2 shared publications- Feiran Zhang
College of Key Laboratory of Special Electric Machines and High Voltage Apparatus of Ministry of Education (Shenyang University of Technology)
2 shared publications - Shidong Peng
Shenyang University of Technology
2 shared publications - Shuxin Liu
Key Lab of Special Electric Machine and High Voltage Apparatus (College of Electrical Engineering, Shenyang University of Technology), Shenyang, China
2 shared publications
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (20) , 205326
Effect of breaking speed on plasma distribution characteristics during the arc extinction process
During the tripping of a direct current (DC) vacuum circuit breaker, a plasma arc is generated between the contacts. Different tripping speeds alter the plasma diffusion space between the contacts, affecting the plasma’s longitudinal and axial diffusion rates. Under identical commutation gap conditions, tripping speed also influences the arc duration, thereby affecting the generation and persistence of the plasma. Consequently, this leads to differences in the plasma energy dissipation rate during the arc extinction phase and the residual plasma quantity after arc extinction. To investigate the effect of tripping speed on the vacuum arc extinction process, a 10 kV DC vacuum circuit breaker was selected as the research subject. A three-dimensional transient magnetohydrodynamic simulation model was established to analyze the influence of tripping speed on arc characteristics and the distribution patterns of temperature, pressure, and velocity fields, followed by experimental verification. The results show that, for a given arc burning duration, increasing the opening speed promotes axial elongation of the arc column and enhances convective transport within the plasma. This leads to accelerated arc quenching, improved arc controllability, and enhanced diffusion of high-temperature plasma. Correspondingly, the temperature, pressure, and velocity fields evolve toward configurations that are more favorable for arc extinction. Therefore, increasing the opening velocity enhances the spatial diffusion and energy dissipation of the plasma, thereby significantly improving the interrupting performance of the circuit breaker.
- 1 October 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (20) , 205326
Effect of breaking speed on plasma distribution characteristics during the arc extinction process
During the tripping of a direct current (DC) vacuum circuit breaker, a plasma arc is generated between the contacts. Different tripping speeds alter the plasma diffusion space between the contacts, affecting the plasma’s longitudinal and axial diffusion rates. Under identical commutation gap conditions, tripping speed also influences the arc duration, thereby affecting the generation and persistence of the plasma. Consequently, this leads to differences in the plasma energy dissipation rate during the arc extinction phase and the residual plasma quantity after arc extinction. To investigate the effect of tripping speed on the vacuum arc extinction process, a 10 kV DC vacuum circuit breaker was selected as the research subject. A three-dimensional transient magnetohydrodynamic simulation model was established to analyze the influence of tripping speed on arc characteristics and the distribution patterns of temperature, pressure, and velocity fields, followed by experimental verification. The results show that, for a given arc burning duration, increasing the opening speed promotes axial elongation of the arc column and enhances convective transport within the plasma. This leads to accelerated arc quenching, improved arc controllability, and enhanced diffusion of high-temperature plasma. Correspondingly, the temperature, pressure, and velocity fields evolve toward configurations that are more favorable for arc extinction. Therefore, increasing the opening velocity enhances the spatial diffusion and energy dissipation of the plasma, thereby significantly improving the interrupting performance of the circuit breaker.
- 1 July 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (7)
Gas-driven arc transport and pressure buildup in a polyamide 66-assisted direct current breaker chamber
Polyamide 66 (PA66) gassing materials are widely used in direct current molded case circuit breakers, yet the fluid-dynamic mechanism by which their decomposition gases regulate arc transport, pressure buildup, and enclosure loading remains insufficiently understood. This study investigates the effects of PA66 position and volume on arc dynamics, chamber pressure, enclosure stress, and shell damage. The results show that PA66 decomposition gases, mainly H2, CO, and H2O, do not merely act as an arc-cooling medium. Instead, they modify local thermophysical properties and generate pressure-driven flow, forming a fluid-dynamic feedback mechanism that couples gas generation, species transport, energy redistribution, arc motion, and structural loading in a confined chamber. Among the investigated configurations, placing PA66 near the corner of the anode arc runner provides the most favorable alignment between gas expansion and magnetically driven arc motion, thereby promoting arc transport toward the splitter plates and reducing enclosure loading. Increasing PA66 volume enhances gas-assisted arc acceleration, but excessive gas generation intensifies pressure accumulation, arc-root stagnation, structural loading, and shell damage. These findings suggest that the PA66 layout should be designed by balancing arc-transport enhancement with enclosure reliability.
- 1 July 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (7)
Gas-driven arc transport and pressure buildup in a polyamide 66-assisted direct current breaker chamber
Polyamide 66 (PA66) gassing materials are widely used in direct current molded case circuit breakers, yet the fluid-dynamic mechanism by which their decomposition gases regulate arc transport, pressure buildup, and enclosure loading remains insufficiently understood. This study investigates the effects of PA66 position and volume on arc dynamics, chamber pressure, enclosure stress, and shell damage. The results show that PA66 decomposition gases, mainly H2, CO, and H2O, do not merely act as an arc-cooling medium. Instead, they modify local thermophysical properties and generate pressure-driven flow, forming a fluid-dynamic feedback mechanism that couples gas generation, species transport, energy redistribution, arc motion, and structural loading in a confined chamber. Among the investigated configurations, placing PA66 near the corner of the anode arc runner provides the most favorable alignment between gas expansion and magnetically driven arc motion, thereby promoting arc transport toward the splitter plates and reducing enclosure loading. Increasing PA66 volume enhances gas-assisted arc acceleration, but excessive gas generation intensifies pressure accumulation, arc-root stagnation, structural loading, and shell damage. These findings suggest that the PA66 layout should be designed by balancing arc-transport enhancement with enclosure reliability.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (6) , 1269-1281
Arc Restrike in DC Contactor During Arc Splitting Process Under Inhomogeneous Magnetic Field and Its Evaluation Methodology
The arc extinguishing performance of existing dc contactors has been challenging to meet the development needs of battery electrical vehicles (BEVs), which is mainly manifested in the frequent arc re-strike when the large-capacity dc contactor is breaking. In this research, the arc re-strike under an inhomogeneous magnetic field was investigated by the numerical model in which the precision was proved by experiment, and the severity of arc re-strike under different copper (Cu) vapor concentrations was evaluated. The thermal re-strike and electrical re-strike can simultaneously simulate in this research, and arc re-strike between the contacts and arc re-strike between the splitter plates was discovered. The results show that increasing the magnetic field is conducive to arc extinction, but increasing the magnetic field above 60 mT has little effect on arc duration. The arc re-strike is become severe when Cu vapor concentration is above 60 %, which is related to the small specific heat at constant pressure Cp and thermal conductivity λ of the mixed gas at high Cu vapor concentration. The magnetic field saturation threshold and arc re-strike evaluation methodology presented in this paper can be used to optimize the configuration of permanent magnets and the geometric dimensions of arc chamber under the premise of meeting the constraints of breaking capacity and arc re-strike risk.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (6) , 1269-1281
Arc Restrike in DC Contactor During Arc Splitting Process Under Inhomogeneous Magnetic Field and Its Evaluation Methodology
The arc extinguishing performance of existing dc contactors has been challenging to meet the development needs of battery electrical vehicles (BEVs), which is mainly manifested in the frequent arc re-strike when the large-capacity dc contactor is breaking. In this research, the arc re-strike under an inhomogeneous magnetic field was investigated by the numerical model in which the precision was proved by experiment, and the severity of arc re-strike under different copper (Cu) vapor concentrations was evaluated. The thermal re-strike and electrical re-strike can simultaneously simulate in this research, and arc re-strike between the contacts and arc re-strike between the splitter plates was discovered. The results show that increasing the magnetic field is conducive to arc extinction, but increasing the magnetic field above 60 mT has little effect on arc duration. The arc re-strike is become severe when Cu vapor concentration is above 60 %, which is related to the small specific heat at constant pressure Cp and thermal conductivity λ of the mixed gas at high Cu vapor concentration. The magnetic field saturation threshold and arc re-strike evaluation methodology presented in this paper can be used to optimize the configuration of permanent magnets and the geometric dimensions of arc chamber under the premise of meeting the constraints of breaking capacity and arc re-strike risk.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-8
Influence of Asynchronous Opening on Arc Characteristics in a Double-Break DC Vacuum Circuit Breaker
Asynchronous opening in a double-break DC vacuum circuit breaker leads to a gap difference between the two interruption gaps, which in turn results in nonuniform arc energy distribution and distinct plasma transport characteristics. In this article, a 24 kV/10 kA double-break DC vacuum circuit breaker is investigated. A numerical model describing asynchronous opening is established to analyze the plasma temperature, pressure, and velocity fields under different gap difference conditions, and the corresponding distribution characteristics and differences are obtained. The results indicate that the gap difference has a significant influence on arc energy and plasma behavior in the double-break configuration. When the gap difference is small, the plasma distributions in the two gaps exhibit similar characteristics, and the arc energy is distributed in a relatively balanced manner. As the gap difference increases, arc constriction in the smaller-gap unit becomes more pronounced, leading to enhanced local energy accumulation and a reduction in the overall energy dissipation capability of the circuit breaker. When the gap difference reaches a critical value, severe imbalance in arc energy and plasma distribution occurs, postarc dielectric recovery is degraded, and arc reignition is triggered, ultimately resulting in interruption failure of the circuit breaker.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-8
Influence of Asynchronous Opening on Arc Characteristics in a Double-Break DC Vacuum Circuit Breaker
Asynchronous opening in a double-break DC vacuum circuit breaker leads to a gap difference between the two interruption gaps, which in turn results in nonuniform arc energy distribution and distinct plasma transport characteristics. In this article, a 24 kV/10 kA double-break DC vacuum circuit breaker is investigated. A numerical model describing asynchronous opening is established to analyze the plasma temperature, pressure, and velocity fields under different gap difference conditions, and the corresponding distribution characteristics and differences are obtained. The results indicate that the gap difference has a significant influence on arc energy and plasma behavior in the double-break configuration. When the gap difference is small, the plasma distributions in the two gaps exhibit similar characteristics, and the arc energy is distributed in a relatively balanced manner. As the gap difference increases, arc constriction in the smaller-gap unit becomes more pronounced, leading to enhanced local energy accumulation and a reduction in the overall energy dissipation capability of the circuit breaker. When the gap difference reaches a critical value, severe imbalance in arc energy and plasma distribution occurs, postarc dielectric recovery is degraded, and arc reignition is triggered, ultimately resulting in interruption failure of the circuit breaker.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Equivalent Regulation Mechanism of Electron Density Distribution in Vacuum Arcs by Transverse Magnetic Fields and Contact Gaps
Taking single-break DC vacuum circuit breakers as the research object, an experimental platform for collecting characteristic information of DC vacuum arcs was established. High-speed cameras were used to capture images of the zero-zone process of vacuum arcs under transverse magnetic fields, flat contacts, and different commutation gaps. Spectrometers were employed to collect characteristic spectral lines at Cu I 521.8 nm, from which electron temperature and electron density were calculated and analyzed. The study found that under the same operating condition with a commutation gap of 6 mm, the swastika-shaped transverse magnetic field (TMF) contacts can effectively regulate the spatial distribution of arc plasma. Compared with the case without magnetic field, the radial distribution uniformity of electron density is significantly improved, and the ratio of electron density between the center and the edge on the cathode contact surface decreases from 7:1 to 1.6:1. Increasing the contact gap can improve the spatial distribution uniformity of electron density. The transverse magnetic field gap (6 mm) and increasing the contact gap (10 mm) under no magnetic field conditions have equivalent regulatory effects on the radial/axial distribution of electron density. Both increasing the gap and enhancing the magnetic field improve the uniformity of plasma spatial distribution and reduce the difference in electron density between the center and edge of the contact surface. The transverse magnetic field can equivalently replace increasing the gap to achieve stable arc control.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Equivalent Regulation Mechanism of Electron Density Distribution in Vacuum Arcs by Transverse Magnetic Fields and Contact Gaps
Taking single-break DC vacuum circuit breakers as the research object, an experimental platform for collecting characteristic information of DC vacuum arcs was established. High-speed cameras were used to capture images of the zero-zone process of vacuum arcs under transverse magnetic fields, flat contacts, and different commutation gaps. Spectrometers were employed to collect characteristic spectral lines at Cu I 521.8 nm, from which electron temperature and electron density were calculated and analyzed. The study found that under the same operating condition with a commutation gap of 6 mm, the swastika-shaped transverse magnetic field (TMF) contacts can effectively regulate the spatial distribution of arc plasma. Compared with the case without magnetic field, the radial distribution uniformity of electron density is significantly improved, and the ratio of electron density between the center and the edge on the cathode contact surface decreases from 7:1 to 1.6:1. Increasing the contact gap can improve the spatial distribution uniformity of electron density. The transverse magnetic field gap (6 mm) and increasing the contact gap (10 mm) under no magnetic field conditions have equivalent regulatory effects on the radial/axial distribution of electron density. Both increasing the gap and enhancing the magnetic field improve the uniformity of plasma spatial distribution and reduce the difference in electron density between the center and edge of the contact surface. The transverse magnetic field can equivalently replace increasing the gap to achieve stable arc control.
- Open Access
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Fluid modeling of CF3I/CO2 arc formation process
The environmentally friendly insulating gas CF3I is a promising replacement for SF6 due to its excellent insulation and arc extinguishing performance. In the arc chamber of high-voltage circuit breakers filled with CF3I/CO2, the near-electrode sheath dominates the current transfer process between contact and arc column during arc formation, which has a significant effect on the transition from glow to arc discharge. The 30%CF3I/70%CO2 was taken as the research object in this research, and a more perfect fluid model was established considering the influence of diffusion current. The arc formation process between the contacts at the preliminary stage of circuit breaker interruption was conducted. The results show that the arc formation process can be divided into three stages: glow discharge, abnormal glow discharge, and arc discharge. As the arc formation process proceeds, the thickness of the near-cathode sheath decreases gradually. When the arc reaches stability with the current density 8×106–1.6×107A·m−2, the thickness of the near-cathode sheath is 7 μm, the steep voltage fall near the cathode sheath is generated within 7 μm away from the cathode surface, and this voltage fall almost does not change with the current density. CF3I− is the dominant negative ion between the contacts, which indicates that CF3I has excellent electron adsorption performance and is beneficial to arc deionization. The computational results of this work were compared with the existing experimental ones, which shows that the model used in this work is accurate enough. Finally, suggestions for model optimization and future work are given.
- 1 February 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (2)
Open AccessFluid modeling of CF3I/CO2 arc formation process
The environmentally friendly insulating gas CF3I is a promising replacement for SF6 due to its excellent insulation and arc extinguishing performance. In the arc chamber of high-voltage circuit breakers filled with CF3I/CO2, the near-electrode sheath dominates the current transfer process between contact and arc column during arc formation, which has a significant effect on the transition from glow to arc discharge. The 30%CF3I/70%CO2 was taken as the research object in this research, and a more perfect fluid model was established considering the influence of diffusion current. The arc formation process between the contacts at the preliminary stage of circuit breaker interruption was conducted. The results show that the arc formation process can be divided into three stages: glow discharge, abnormal glow discharge, and arc discharge. As the arc formation process proceeds, the thickness of the near-cathode sheath decreases gradually. When the arc reaches stability with the current density 8×106–1.6×107A·m−2, the thickness of the near-cathode sheath is 7 μm, the steep voltage fall near the cathode sheath is generated within 7 μm away from the cathode surface, and this voltage fall almost does not change with the current density. CF3I− is the dominant negative ion between the contacts, which indicates that CF3I has excellent electron adsorption performance and is beneficial to arc deionization. The computational results of this work were compared with the existing experimental ones, which shows that the model used in this work is accurate enough. Finally, suggestions for model optimization and future work are given.