ZLZixuan Li

Zixuan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zixuan Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Zhikang Li

    School of Instrument Science and Technology Xi'an Jiaotong University Xi'an China

    6 shared publications
  • Jiawei Yuan

    State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an 710049, China

    5 shared publications
  • Jie Li

    School of Mechanical and Electrical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China

    5 shared publications
  • Libo Zhao

    School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China

    5 shared publications
  • Shaohui Qin

    State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Research Institute for Intelligent Sensing Technology and System (Yantai), School of Instrument Science and Technology, School of Mechanical Engineering, Xian Jiaotong University, Xian, China

    5 shared publications
  • Yihe Zhao

    State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xian Jiaotong University (Yantai) Research Institute for Intelligent Sensing Technology and System, the School of Instrument Science and Technology, and the School of Mechanical Engineering, Xian Jiaotong University, Xian, China

    5 shared publications

Latest Publications

  • Design and Modeling of CMUTs With T-Shape Cavities for Low Working Voltage, High Ultrasound Transmission and Reception

    by Zhikang Li, Shaohui Qin, Jiawei Yuan, Jie Li, Yihe Zhao, Hongqiang Tan, Zixuan Li, Zheng Yuan, Ruiyan Luo, Hefeng Qin, et al.

    Low-voltage, high-performance capacitive micromachined ultrasonic transducers (CMUTs) are in urgent demand for portable ultrasound imaging and human-machine interfaces. However, most existing CMUTs exhibit superior comprehensive performance due to conflicting requirements in their structural design, which constrains their practical applications. This paper proposes a novel CMUT with T-shape cavities to achieve synergistic enhancement of multiple key performances by harnessing the electrostatic stiffness softening effect (ESSE). The unique T-shape cavity design features a smaller electrode distance in the peripheral area compared to the central area, which produces a higher electric field intensity and thus a larger membrane stiffness drop in the peripheral area of the vibrating membrane through the corresponding enhancement of ESSE. This special stiffness adjustment strategy ultimately enables the entire membrane to produce piston-like deformation, significantly improving both the maximum and average membrane deformation, and contributing to enhancements in operation voltage, transmitting and receiving sensitivities, electromechanical coupling coefficient, etc. The finite element method (FEM) is employed to investigate the device’s performance. Compared to conventional CMUTs, T-CMUTs reduce collapse voltage by 36.2%, with transmitting/receiving sensitivities and electromechanical coupling coefficient improved by 56.1%, 62.6%, and 76.0% under the same bias ratios; furthermore, these parameters improve by 371.0%, 516.0%, and 618.4% respectively at same bias voltages. An analysis of the stress distribution of the membrane further verifies the underlying mechanism of the T-shape cavity in enhancing device performance. Additionally, the foreseeable simple process and feasibility in consistent fabrication endow the proposed CMUTs with significant potential for practical application.


  • A theoretical model of electromechanical coupling for CMUTs with annular electrodes based on the Ritz method

    by Jie Li, Zhaohui Xiao, Zutang Wu, Kuiwei Shi, Zhikang Li, Yihe Zhao, Hao Wu, Zixuan Li, Min Li, Libo Zhao


  • Array Equivalent Circuit Model and Experimental Analysis of Square CMUTs

    by Jie Li, Zutang Wu, Jin Li, Zhaohui Xiao, Zhikang Li, Yihe Zhao, Guoxi Luo, Jiawei Yuan, Zixuan Li, Shaohui Qin, et al.

    The equivalent circuit is a commonly used tool for performance analysis during CMUT design and optimization. In this study, the immersion equivalent circuit model of square CMUT array is established for the first time. Using this model, the vibration, electrical, and acoustic characteristics of square CMUTs can be rapidly analyzed. Consequently, it can replace the time-consuming finite element model for design and optimization. For comparison with the equivalent circuit model presented in this paper, the finite element model of the square CMUT array was established by COMSOL 6.0a. The theoretical calculation results of the equivalent circuit model are highly consistent with the FEM results. Finally, a 28×28 CMUT array composed of square cells was fabricated using the wafer bonding process, and its vibration and impedance characteristics were tested using a Laser Doppler Vibrometer and an impedance analyzer. All experimental results well verified the accuracy of the proposed equivalent circuit models.


  • Pb(Zr0.5Ti0.5)O3-Based Piezoelectric Micromachined Ultrasonic Transducers for High Acoustic Transmission and Reception

    by Zixuan Li, Zhikang Li, Yihe Zhao, Jiawei Yuan, Zilong Zhao, Qi Ma, Shaohui Qin, Xuan Shi, Xiaozhang Wang, Libo Zhao

    Piezoelectric micromachined ultrasonic transducers (PMUTs) show great promise in portable medical diagnostic systems and non-contact ranging finding due to their miniature size, high acoustic impedance matching with human tissue, low power consumption, and easy integration with ICs. This paper presents a highly transmitting and receiving PMUTs using Pb(Zr 50 Ti 50 )O 3 as the piezoelectric layer. A low-temperature and high-piezoelectricity Pb(Zr 50 Ti 50 )O 3 thin film fabrication technique is developed The fabricated piezoelectric film features the lowest film-forming temperature (≤ 480 °C) ever reported, excellent piezoelectric coefficient (15.5 C/m²) and lower dielectric constant (750). As a result, the developed PMUTs achieves a transmitting sensitivity of 4.72 kPa/V, a -6 dB fractional bandwidth of 80.2 % and a high reception signal-to-noise ratio up to 37.3 dB and 18.9 dB without any amplifier circuits, demonstrating high comprehensive performances compared with previously reported PMUTs with the similar structures. This study may accelerate the development of CMOS-compatible and high-performance PMUTs based on thin PZT film.


  • Noninvasive Stress Detection Based on Piezoelectric Micromachined Ultrasonic Transducers for Bolt Loosening Warning

    by Zhikang Li, Jiazhu Li, Yihe Zhao, Zixuan Li, Xuan Shi, Shaohui Qin, Jie Li, Jiawei Yuan, Qi Ma, Zilong Zhao, et al.

    Axial stress monitoring of bolts is significant to various engineering structures and machines because it can assist their reliable and durable operation, and prevent major failures and safety accidents. Among various sensing technologies, ultrasound holds prominent advantages in accuracy, noninvasiveness, non-destructive testing, etc. However, current ultrasonic technique predominantly relies on conventional bulk-PZT ultrasonic transducers, which suffer large size, high-power consumption, and inferior integration with ICs, hindering real-time and long-term monitoring and application in small bolts. This paper highlights the prospect of piezoelectric micromachined ultrasonic transducers (PMUT) in aforementioned application situations based on acoustic elastic effects and bolt length variations induced time differences. The corresponding theories for the relationship between the time difference and the stress are validated by finite element methods. A specific PMUTs with inner circular and outer annular arrays and optimized ultrasound frequencies were proposed to improve sensing performance. As such, the axial stress variation in a steel bolt with a nominal diameter as small as 6 mm is successfully monitored using our fabricated PMUTs chip with a resonant frequency of 850 kHz. Excellent linearity (≥0.998) between the ToF difference and applied stress and a high accuracy of less than 3% are demonstrated. Further, experimental testing of bolt stress under different practical conditions, such as bolt sizes, materials, and connection types validates the performance robustness and widespread applicability of our proposed PMUT-based ultrasonic stress sensing technique.


  • Modeling and Optimization of CMUTs Arrays for Improved Transmission and Reception Performance in Immersion

    by Zhikang Li, Jiawei Yuan, Jie Li, Zixuan Li, Yihe Zhao, Shaohui Qin, Qi Ma, Xuan Shi, Min Li, Zheng Yuan, et al.

    Capacitive micromechanical ultrasonic transducers (CMUTs) have widespread applications in ultrasonic imaging, therapeutic treatment, and underwater applications. Reasonable design of their array structures essentially determines the performance in aforementioned applications. However, there is a lack of a systematic investigation on the design strategies and effects of structure parameters of CMUTs arrays, significantly impeding their performance improvement. This paper constructs explicit and accurate analytical expressions for the main performances of CMUTs arrays in immersion by introducing the accurate distributed membrane deflection. Based on these theories, the influence laws of the aforementioned structure parameters on the CMUTs array performances are analyzed and summarized in detail, including the transmitting power, receiving sensitivity, focal length, beamwidth, etc. These theories and array performance variation rules are well validated by finite element method (FEM) simulations and experiment results of our fabricated CMUTs chips. It is demonstrated by the FEM simulation that, under specific array structural parameters, the fill factor has a significant improvement effect on CMUTs bandwidth (up to 173%). The multi arm spiral array and ring-shape array reduce the sidelobe level (62% less than that of conventional square arrays) and improve the transmitting power and receiving sensitivity (35% and 33% larger than that of conventional circular arrays), respectively. Based on these, CMUTs array design and optimization strategies are provided for typical ultrasonic applications. This study provides a theoretical basis for the design and application of CMUTs arrays in immersion, which will accelerate the development of CMUTs devices.