Athanasios Delis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Athanasios Delis has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- George Tsavdaridis
School of Electrical & Computer Engineering, National Technical University of Athens, 9, Iroon Polytechniou Str., 15772 Athens, Greece, Greece
3 shared publications - Despoina-Polyxeni Georgiou
School of Electrical & Computer Engineering, National Technical University of Athens, 157 80 Zografou, Greece
2 shared publications - Eleni Alexandratou
Laboratory of Biomedical Optics and Applied Biophysics, School of Electrical and Computer Engineering, National Technical University of Athens, Athens, Greece
2 shared publications - Ioannis Stamelos
1st Department of Neurology, Aiginition Hospital, National and Kapodistrian University of Athens Medical School, 11528 Athens, Greece
2 shared publications - Konstantinos Politopoulos
School of Electrical & Computer Engineering, National Technical University of Athens, 157 80 Zografou, Greece
2 shared publications - Panayiotis Tsanakas
National and Technical University of Athens
2 shared publications
Latest Publications
- Open Access
Religious Psychopathology: Overview of Clinical, Cultural, and Neurobiological Perspectives
Religious psychopathology as a field lies at the intersection of psychiatry, theology, and culture. It addresses scientific discoveries and questions relating to the manifestation of mental health disorders that are expressed through religious content, ideation, and/or behavior. Religious psychopathology, being a multifaceted phenomenon, challenges clinicians, researchers, and religious leaders because it is non-trivial to distinguish between culturally normative religious experiences and pathological symptoms. The present integrative narrative review examines historical perspectives, diagnostic challenges, clinical manifestations, cultural considerations, therapeutic interventions, neurobiological models, ethical issues, and future directions in the field of religious psychopathology. It focuses primarily on literature from 2013 to 2025, while also incorporating selected foundational historical, theoretical, and clinical sources necessary for conceptual clarification. A special emphasis is placed on culturally informed and interdisciplinary approaches. Particular focus is given to approaches that respect spiritual frameworks while concurrently promoting evidence-based mental health care.
Open AccessReligious Psychopathology: Overview of Clinical, Cultural, and Neurobiological Perspectives
Religious psychopathology as a field lies at the intersection of psychiatry, theology, and culture. It addresses scientific discoveries and questions relating to the manifestation of mental health disorders that are expressed through religious content, ideation, and/or behavior. Religious psychopathology, being a multifaceted phenomenon, challenges clinicians, researchers, and religious leaders because it is non-trivial to distinguish between culturally normative religious experiences and pathological symptoms. The present integrative narrative review examines historical perspectives, diagnostic challenges, clinical manifestations, cultural considerations, therapeutic interventions, neurobiological models, ethical issues, and future directions in the field of religious psychopathology. It focuses primarily on literature from 2013 to 2025, while also incorporating selected foundational historical, theoretical, and clinical sources necessary for conceptual clarification. A special emphasis is placed on culturally informed and interdisciplinary approaches. Particular focus is given to approaches that respect spiritual frameworks while concurrently promoting evidence-based mental health care.
- Open Access
- 29 December 2024
- Published by MDPI AG in Electronics
- Vol. 14 (1) , 95
A Novel Multi-Feedback Differential Filter Instrumentation Amplifier for Βiosignals Acquisition Applications
Efficient filtering in biosignals acquisition is challenging. The resistance of the sources exhibits inter- and intra-subject variability or is unknown; thus, using passive filters before the first amplification stage is problematic. Conversely, filtering after amplification does not effectively eliminate the amplified electrical noise, main’s interference, and the artifacts. In this context, the design and utilization of filters in the analog front end of biosensors, in conjunction with the first amplification stage, is not common but offers substantial advantages. In this study, the design of a novel Multi-feedback Differential Filter Instrumentation Amplifier (MFDFIA) is proposed. The design and the equations governing the gain and bandwidth characteristics of the MFDFIA are presented, and relevant topologies are explored. Even though MFDFIA has two op-amps in its first stage, due to its symmetric topology, the analysis can be conducted separately for the differential- and common-mode input signal with a simplified one op-amp equivalent circuit. Notably, MFDFIA’s CMRR is equal and depends only on the CMRR of the second stage. An exemplary simulation for EEG signal acquisition is provided, with a flat band of 1db between 0.7 Hz and 25.4 Hz, a gain of 34.1 db, and an input noise of 70.66 nVrms in the range of 0.1–10 Hz.
- 29 December 2024
- Published by MDPI AG in Electronics
- Vol. 14 (1) , 95
Open AccessA Novel Multi-Feedback Differential Filter Instrumentation Amplifier for Βiosignals Acquisition Applications
Efficient filtering in biosignals acquisition is challenging. The resistance of the sources exhibits inter- and intra-subject variability or is unknown; thus, using passive filters before the first amplification stage is problematic. Conversely, filtering after amplification does not effectively eliminate the amplified electrical noise, main’s interference, and the artifacts. In this context, the design and utilization of filters in the analog front end of biosensors, in conjunction with the first amplification stage, is not common but offers substantial advantages. In this study, the design of a novel Multi-feedback Differential Filter Instrumentation Amplifier (MFDFIA) is proposed. The design and the equations governing the gain and bandwidth characteristics of the MFDFIA are presented, and relevant topologies are explored. Even though MFDFIA has two op-amps in its first stage, due to its symmetric topology, the analysis can be conducted separately for the differential- and common-mode input signal with a simplified one op-amp equivalent circuit. Notably, MFDFIA’s CMRR is equal and depends only on the CMRR of the second stage. An exemplary simulation for EEG signal acquisition is provided, with a flat band of 1db between 0.7 Hz and 25.4 Hz, a gain of 34.1 db, and an input noise of 70.66 nVrms in the range of 0.1–10 Hz.
- Open Access
- 18 November 2024
- Published by MDPI AG in Preprints.org
A Novel Multi-Feedback Differential Filter Instrumentation Amplifier for Βiosignals Acquisition Applications
Efficient filtering in bio-signals acquisition is challenging. The resistance of the sources exhibits inter- and intra-subject variability or is unknown, thus using passive filters before the first amplification stage is problematic. Conversely, filtering after amplification does not effectively eliminate the amplified electrical noise, Main’s Interference, and the artifacts. In this context, the design and utilization of filters in the Analog Front End of biosensors, in conjunction with the first amplification stage, is not common but offers substantial advantages. In this study, the design of a novel Multi-feedback Differential Filter Instrumentation Amplifier (MFDFIA) is proposed. For addressing the aforementioned issues, the design and the equations governing the gain and bandwidth characteristics of the MFDFIA are presented and relevant topologies are explored. Even though MFDFIA has two op-amps in its first stage, due to its symmetric topology, the analysis can be conducted separately for the differential and common mode input signal with a simplified one op-amp equivalent circuit. Notably, MFDFIA’s CMRR is equal and depends only on the CMRR of the second stage. An exemplary application for EEG signal acquisition is provided, which has bandwidth 0.7 to 98.6 Hz, gain 50.3 db, power consumption 11.583 mW and 0.1-10 Hz noise 462.94 nVrms.
- 18 November 2024
- Published by MDPI AG in Preprints.org
Open AccessA Novel Multi-Feedback Differential Filter Instrumentation Amplifier for Βiosignals Acquisition Applications
Efficient filtering in bio-signals acquisition is challenging. The resistance of the sources exhibits inter- and intra-subject variability or is unknown, thus using passive filters before the first amplification stage is problematic. Conversely, filtering after amplification does not effectively eliminate the amplified electrical noise, Main’s Interference, and the artifacts. In this context, the design and utilization of filters in the Analog Front End of biosensors, in conjunction with the first amplification stage, is not common but offers substantial advantages. In this study, the design of a novel Multi-feedback Differential Filter Instrumentation Amplifier (MFDFIA) is proposed. For addressing the aforementioned issues, the design and the equations governing the gain and bandwidth characteristics of the MFDFIA are presented and relevant topologies are explored. Even though MFDFIA has two op-amps in its first stage, due to its symmetric topology, the analysis can be conducted separately for the differential and common mode input signal with a simplified one op-amp equivalent circuit. Notably, MFDFIA’s CMRR is equal and depends only on the CMRR of the second stage. An exemplary application for EEG signal acquisition is provided, which has bandwidth 0.7 to 98.6 Hz, gain 50.3 db, power consumption 11.583 mW and 0.1-10 Hz noise 462.94 nVrms.
- Open Access
- 6 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (16) , 6886
A Novel Battery-Supplied AFE EEG Circuit Capable of Muscle Movement Artifact Suppression
In this study, the fundamentals of electroencephalography signals, their categorization into frequency sub-bands, the circuitry used for their acquisition, and the impact of noise interference on signal acquisition are examined. Additionally, design specifications for medical-grade and research-grade EEG circuits and a comprehensive analysis of various analog front-end architectures for electroencephalograph (EEG) circuit design are presented. Three distinct selected case studies are examined in terms of comparative evaluation with generic EEG circuit design templates. Moreover, a novel one-channel battery-supplied EEG analog front-end circuit designed to address the requirements of usage protocols containing strong compound muscle movements is introduced. Furthermore, a realistic input signal generator circuit is proposed that models the human body and the electromagnetic interference from its surroundings. Experimental simulations are conducted in 50 Hz and 60 Hz electrical grid environments to evaluate the performance of the novel design. The results demonstrate the efficacy of the proposed system, particularly in terms of bandwidth, portability, Common Mode Rejection Ratio, gain, suppression of muscle movement artifacts, electrostatic discharge and leakage current protection. Conclusively, the novel design is cost-effective and suitable for both commercial and research single-channel EEG applications. It can be easily incorporated in Brain–Computer Interfaces and neurofeedback training systems.
- 6 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (16) , 6886
Open AccessA Novel Battery-Supplied AFE EEG Circuit Capable of Muscle Movement Artifact Suppression
In this study, the fundamentals of electroencephalography signals, their categorization into frequency sub-bands, the circuitry used for their acquisition, and the impact of noise interference on signal acquisition are examined. Additionally, design specifications for medical-grade and research-grade EEG circuits and a comprehensive analysis of various analog front-end architectures for electroencephalograph (EEG) circuit design are presented. Three distinct selected case studies are examined in terms of comparative evaluation with generic EEG circuit design templates. Moreover, a novel one-channel battery-supplied EEG analog front-end circuit designed to address the requirements of usage protocols containing strong compound muscle movements is introduced. Furthermore, a realistic input signal generator circuit is proposed that models the human body and the electromagnetic interference from its surroundings. Experimental simulations are conducted in 50 Hz and 60 Hz electrical grid environments to evaluate the performance of the novel design. The results demonstrate the efficacy of the proposed system, particularly in terms of bandwidth, portability, Common Mode Rejection Ratio, gain, suppression of muscle movement artifacts, electrostatic discharge and leakage current protection. Conclusively, the novel design is cost-effective and suitable for both commercial and research single-channel EEG applications. It can be easily incorporated in Brain–Computer Interfaces and neurofeedback training systems.
- Open Access
- 3 June 2024
- Published by MDPI AG in Preprints.org
A Novel Battery-Supplied AFE EEG Circuit Capable of Muscle Movement Artifact Suppression
In this study, the fundamentals of electroencephalography signals, their categorization into frequency sub-bands, the circuitry used for their acquisition, and the impact of noise interference on signal acquisition are examined. Additionally, design specifications for medical-grade and research-grade EEG circuits and a comprehensive analysis of various analog front-end architectures for electroencephalograph (EEG) circuit design are presented. Three distinct selected case studies are examined in terms of comparative evaluation with generic EEG circuit design templates. Moreover, a novel one-channel battery-supplied EEG analog front-end circuit designed to address the requirements of usage protocols containing strong com-pound muscle movements is introduced. Furthermore, a realistic input signal generator circuit is proposed that models the human body and the Electromagnetic Interference from its surroundings. Experimental simulations are conducted in 50 Hz and 60 Hz electrical grid environments to evaluate the performance of the novel design. The results demonstrate the efficacy of the proposed system, particularly in terms of bandwidth, portability, common mode rejection ratio , gain, suppression of muscle movement artifacts, electrostatic discharge and leakage current protection. Conclusively, the novel design is cost-effective and suitable for both commercial and research single-channel EEG applications. It can be easily incorporated in Brain Computer Interfaces and neurofeedback training systems.
- 3 June 2024
- Published by MDPI AG in Preprints.org
Open AccessA Novel Battery-Supplied AFE EEG Circuit Capable of Muscle Movement Artifact Suppression
In this study, the fundamentals of electroencephalography signals, their categorization into frequency sub-bands, the circuitry used for their acquisition, and the impact of noise interference on signal acquisition are examined. Additionally, design specifications for medical-grade and research-grade EEG circuits and a comprehensive analysis of various analog front-end architectures for electroencephalograph (EEG) circuit design are presented. Three distinct selected case studies are examined in terms of comparative evaluation with generic EEG circuit design templates. Moreover, a novel one-channel battery-supplied EEG analog front-end circuit designed to address the requirements of usage protocols containing strong com-pound muscle movements is introduced. Furthermore, a realistic input signal generator circuit is proposed that models the human body and the Electromagnetic Interference from its surroundings. Experimental simulations are conducted in 50 Hz and 60 Hz electrical grid environments to evaluate the performance of the novel design. The results demonstrate the efficacy of the proposed system, particularly in terms of bandwidth, portability, common mode rejection ratio , gain, suppression of muscle movement artifacts, electrostatic discharge and leakage current protection. Conclusively, the novel design is cost-effective and suitable for both commercial and research single-channel EEG applications. It can be easily incorporated in Brain Computer Interfaces and neurofeedback training systems.
- Open Access
- 28 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1995
Methodologies and Handling Techniques of Large-Scale Information in Decision Support Systems for Complex Missions
Designing integrating systems for support, real-time monitoring, and executing of complex missions is challenging, since they often fail due to high levels of complexity and overwhelming volume of input data. Past attempts have resorted to “ad hoc” solutions, which face issues of being non-updatable, non-upgradable, and not applicable to similar missions, necessitating a complete redesign and reconstruction of the system. In the national defense and security sector, the impact of this reconstruction requirement leads to significant costs and delays. This study presents advanced methodologies for organizing large-scale datasets and handling complex operational procedures systematically, enhancing the capabilities of Decision Support Systems (DSSs). By introducing Complex Mission Support Systems (CMSSs), a novel SS sub-component, improved accuracy and effectiveness are achieved. The CMSS includes mission conceptualization, analysis, real-time monitoring, control dynamics, execution strategies, and simulations. These methods significantly aid engineers in developing DSSs that are highly user-friendly and operational, thanks to human-reasoning-centered design, increasing performance and efficiency. In summary, the systematic development of data cores that support complex processes creates an adaptable and adjustable framework in a wide range of diverse missions. This approach significantly enhances the overall sustainability and robustness of an integrated system.
- 28 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (5) , 1995
Open AccessMethodologies and Handling Techniques of Large-Scale Information in Decision Support Systems for Complex Missions
Designing integrating systems for support, real-time monitoring, and executing of complex missions is challenging, since they often fail due to high levels of complexity and overwhelming volume of input data. Past attempts have resorted to “ad hoc” solutions, which face issues of being non-updatable, non-upgradable, and not applicable to similar missions, necessitating a complete redesign and reconstruction of the system. In the national defense and security sector, the impact of this reconstruction requirement leads to significant costs and delays. This study presents advanced methodologies for organizing large-scale datasets and handling complex operational procedures systematically, enhancing the capabilities of Decision Support Systems (DSSs). By introducing Complex Mission Support Systems (CMSSs), a novel SS sub-component, improved accuracy and effectiveness are achieved. The CMSS includes mission conceptualization, analysis, real-time monitoring, control dynamics, execution strategies, and simulations. These methods significantly aid engineers in developing DSSs that are highly user-friendly and operational, thanks to human-reasoning-centered design, increasing performance and efficiency. In summary, the systematic development of data cores that support complex processes creates an adaptable and adjustable framework in a wide range of diverse missions. This approach significantly enhances the overall sustainability and robustness of an integrated system.