Demetris Taliotis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Demetris Taliotis has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Alan Pateman
Noah’s Ark Children’s Hospital for Wales, Cardiff, UK
1 shared publicationAndrew Tometzki
Bristol Royal Hospital for Children, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
1 shared publicationFrancisco Gonzalez Barlatay
Bristol Royal Hospital for Children, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
1 shared publicationJack J. C. Gibb
Bristol Royal Hospital for Children, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
1 shared publicationMassimo Caputo
Bristol Royal Hospital for Children, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
1 shared publicationWan Cheol Kim
Division of Cardiology, Department of Medicine, Dalhousie University, Halifax, Canada
1 shared publication
Latest Publications
- Open Access
- 5 February 2024
- Published by Springer Nature in Pediatric Cardiology
- Vol. 45 (3) , 544-551
Medium-Term Outcomes of Stent Therapy for Aortic Coarctation in Children Under 30 kg with New Generation Low-Profile Stents: A Follow-Up Study of a Single Centre Experience
We previously reported short-term outcomes for stenting of aortic coarctation (CoA) (native or re-coarctation) with newer generation low-profile stents (Valeo, Formula, and Begraft stents) in children under 30 kg. We present here the medium-term outcomes of this procedure. Retrospective review of patients weighing under 30 kg who had percutaneous stent treatments for coarctation between 2012 and 2021 was performed. Clinical and procedural data were collected; 19 patients were included. The median age at the time of procedure was 5.1 [4.1–6.4] years and median weight 21.0 [17.3–22.3] kg. One patient had a history of re-coarctation. Thirteen (68%) patients were on anti-hypertensives pre-procedure. Different types of stents were used (14 Valeo™, 4 Formula® 535, 1 BeGraft), which can all be dilated to 18 mm or larger. One patient required a 9 F sheath, all others required a 7 F sheath. The narrowest diameter in the aorta increased from a median of 3.5 [3.0–4.5] to 9.4 [8.9–9.8] mm, p < 0.001; there was a reduction in the median pressure gradient across the coarctation from 35.0 [30.0–43.0] to 5.0 [0–10.0] mmHg, p < 0.001. There were no intra-procedural complications. Follow-up was for a median of 56.0 [13.0–65.0] months. Five (26%) of patients underwent re-intervention after a median time frame of 40.0 [39.5–52.0] months; four had balloon dilation, one had repeat stent implantation. Five (26%) patients were on anti-hypertensive agent(s) post-intervention. Our single centre experience demonstrates that percutaneous stenting for coarctation of aorta in children under 30 kg, with low-profile stents, had no significant complications during the median follow-up time of 56 months. This study demonstrated that the procedure is safe and effective for short and medium-term therapy in this group of patients with a 26% re-intervention rate. A quarter of patients remained on anti-hypertensive medication post stenting, emphasizing the importance of long-term follow-up.
- 5 February 2024
- Published by Springer Nature in Pediatric Cardiology
- Vol. 45 (3) , 544-551
Open AccessMedium-Term Outcomes of Stent Therapy for Aortic Coarctation in Children Under 30 kg with New Generation Low-Profile Stents: A Follow-Up Study of a Single Centre Experience
We previously reported short-term outcomes for stenting of aortic coarctation (CoA) (native or re-coarctation) with newer generation low-profile stents (Valeo, Formula, and Begraft stents) in children under 30 kg. We present here the medium-term outcomes of this procedure. Retrospective review of patients weighing under 30 kg who had percutaneous stent treatments for coarctation between 2012 and 2021 was performed. Clinical and procedural data were collected; 19 patients were included. The median age at the time of procedure was 5.1 [4.1–6.4] years and median weight 21.0 [17.3–22.3] kg. One patient had a history of re-coarctation. Thirteen (68%) patients were on anti-hypertensives pre-procedure. Different types of stents were used (14 Valeo™, 4 Formula® 535, 1 BeGraft), which can all be dilated to 18 mm or larger. One patient required a 9 F sheath, all others required a 7 F sheath. The narrowest diameter in the aorta increased from a median of 3.5 [3.0–4.5] to 9.4 [8.9–9.8] mm, p < 0.001; there was a reduction in the median pressure gradient across the coarctation from 35.0 [30.0–43.0] to 5.0 [0–10.0] mmHg, p < 0.001. There were no intra-procedural complications. Follow-up was for a median of 56.0 [13.0–65.0] months. Five (26%) of patients underwent re-intervention after a median time frame of 40.0 [39.5–52.0] months; four had balloon dilation, one had repeat stent implantation. Five (26%) patients were on anti-hypertensive agent(s) post-intervention. Our single centre experience demonstrates that percutaneous stenting for coarctation of aorta in children under 30 kg, with low-profile stents, had no significant complications during the median follow-up time of 56 months. This study demonstrated that the procedure is safe and effective for short and medium-term therapy in this group of patients with a 26% re-intervention rate. A quarter of patients remained on anti-hypertensive medication post stenting, emphasizing the importance of long-term follow-up.